SECO-LARM Universal Door Strike
8
SECO-LARM U.S.A., Inc.
Wiring Diagram:
1.
Use the included wiring connector marked 24VDC and
connect its black wire to (–) and its white wire to (+).
2.
Plug the male wiring connector into the female wiring
harness connector of the door strike.
1.
Use the included wiring connector marked 12VDC and
connect its black wire to (–) and its red wire to (+).
2.
Plug the male wiring connector into the female wiring
harness connector of the door strike.
For 12VDC operation:
12V
For 24VDC operation:
24V
Black Wire
Red Wire
White Wire
12VDC
24VDC
SECO-LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Website: www.seco-larm.com
Phone: (949) 261-2999 | (800) 662-0800 Email: [email protected]
®
PITGW1
MI_SD-996C-NUQ_190617.docx
NOTICE:
The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM
reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints. All trademarks
are the property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2019 SECO-LARM U.S.A., Inc. All
rights reserved.
WARRANTY:
This SECO-LARM product is warranted against defects in material and workmanship while used in normal
service for three (3) years from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or
replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if
damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration,
improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment
is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of
SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s
option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property
damage of any kind to the purchaser or anyone else.
Troubleshooting:
Door does not open when the
electric strike is activated
Dismount the strike and check that the wiring connector is
connected properly.
Ensure the wiring connector is connected to a 12 or 24VDC
source.
Use a multimeter to test that the strike is receiving the proper
voltage and amperage. If it is not, it may be necessary to use
heavier gauge wires, or increase the output of the power supply.
Make sure the activation device (keypad or push-button switch)
is working properly.
Electric strike does not activate
Check that the door latch is operating properly, and replace if
necessary.
The position of the electric strike may need to be adjusted by
moving it or adding washers or shims.
Strike makes a buzzing sound
Use DC power supply instead of AC power.