background image

SECO-LARM Universal Door Strike 

 

2

 

                                                        

SECO-LARM U.S.A., Inc.

 

 

 

 

The SECO-LARM 

SD-996C-NUQ

 Universal Door Strike can be used with virtually any cylindrical-locking 

system and can be configured for use in wood, aluminum, or metal doors. Included are three different 
ANSI-sized faceplates that can be easily installed on the strike to match the door frame type. The strike is 
easily field-configurable for fail-safe or fail-secure applications. 

Table of Contents: 

Introduction ............................................................ 2 
Specifications ........................................................ 2 
Parts List ................................................................ 2 
Installation ............................................................. 2 
Measuring the Latch & Center Lines ..................... 3 
Mounting the Template .......................................... 3 
Preparing the Door Frame ..................................... 4 
Mounting the Trim Plate ........................................ 4 

Introduction: 

Installation: 

Operating voltage 

12/24 VDC ±15% 

Current draw 

12VDC 300mA 

 

24VDC 150mA 

 

Operating temperature 

32°~120° F (0°~49° C) 

Operating humidity 

0~85%, non-condensing 

Static strength 

1,000-lb (4,448N) 

Dynamic strength 

50ft-lb (68J) 

Endurance 

250,000 cycles (UL Tested), Level IV 

Destructive attack 

Level I 

Line security 

Level I 

Standby power 

Level I 

Specifications: 

Note: 

Not all parts will be used in every installation.

 

1.

 

Select the type of faceplate that will be used. See "Sample Installations," pgs. 5-7. If the door is pre-cut 
for a strike, skip to step 6. 

2.

 

Measure and mark the door latch line and the center line of the door. See "Measuring the Latch Line & 
Center Lines," pg. 3. 

3.

 

Apply the included stick-on template to the door frame. See "Mounting the Template," pg. 3. 

4.

 

Prepare the door frame for installation and mount the trim plate if needed. See "Preparing the Door 
Frame" and "Mounting the Trim Plate," pg. 4. 

5.

 

If the door frame material is unsuitable for mounting the strike directly, use the included mounting tabs 
and small black anchor nuts for installation. This is recommended for aluminum door frames. See 
"Mounting the Strike Using Mounting Tabs," pg. 4. 

6.

 

Program for either fail-safe or fail-secure operation. See "Selecting Fail-Secure or Fail-Safe," pg. 4. 

7.

 

Connect to power. See "Wiring Diagram," pg. 8.  

Parts List: 

Mounting the Strike Using Mounting Tabs ................. 4 
Selecting Fail-Secure or Fail-Safe ............................. 4 
Sample Installations ............................................... 5~7 
  Aluminum Door Frame Installation ......................... 5 
  Hollow Metal Door Frame Installation ..................... 6 
  Wood Door Frame Installation ................................ 7 
Wiring Diagram ........................................................... 8 
Troubleshooting  ........................................................ 8 

Door Strike ......................................................... x  1 
Mounting Plates ................................................. x  3 
 

SD-996RA-11Q - 

For aluminum door frames

                      

 SD-996SS-11Q 

For hollow metal door frames

 

 SD-996RA-31Q 

For wood door frames

 

Mounting template ............................................. x  1 
Electrical connectors ......................................... x  2 
Trim plate ........................................................... x  1 

Trim plate screws .............................................. x  2 

Wiring Connectors ............................................. x  2 
Mounting tabs .................................................... x  2 
Wood screws ..................................................... x  2 
Machine screws ................................................. x  4 
Machine screws (narrow) .................................. x  2 
Phillips screws ................................................... x  2 
Black anchor nuts .............................................. x  2 

Summary of Contents for SD-996C-NUQ

Page 1: ...ted on the door Wiring methods shall be in accordance with NFPA70 Optional lip extension brackets available SD 995C LE25 1 Lip Extension SD 995C LE50 2 Lip Extension Field selectable for fail safe or...

Page 2: ...2 Measure and mark the door latch line and the center line of the door See Measuring the Latch Line Center Lines pg 3 3 Apply the included stick on template to the door frame See Mounting the Template...

Page 3: ...from the side of the door frame and distance Y from the top of the door frame Use a pencil to mark the exact spot where the two lines intersect 2 Carefully peel off the short thin tab in the center of...

Page 4: ...me Mounting the Strike Using Mounting Tabs To mount the strike where the hollow door frame material is unsuitable for mounting do the following 1 Punch or drill holes according to the template for ins...

Page 5: ...ecommended to use the short brushed aluminum SD 996RA 11Q faceplate with the mounting tabs shown in Mounting the Strike Using Mounting Tabs pg 4 SD 996RA 11Q A 33 8 86mm B 5 8 17mm C 3 8 9mm D1 1 8 3m...

Page 6: ...9mm Measurement Key 5 8 16mm 47 8 124mm 11 4 32mm 17 16 36mm 33 8 86mm 41 8 105mm SECO LARM 1 Refers to the thickness of the faceplate 1 Note If it is necessary to cut a hole in the frame mounting tab...

Page 7: ...18mm Measurement Key A 33 8 86mm B 5 8 17mm C 7 16 11mm D1 1 8 3mm E 117 32 39mm F 15 16 33mm Sample Installations Continued Wood Door Frame Installation 1 Refers to the thickness of the faceplate 1...

Page 8: ...ent of any defective part if the unit is returned transportation prepaid to SECO LARM This Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse n...