SECO-LARM Universal Door Strike
2
SECO-LARM U.S.A., Inc.
The SECO-LARM
SD-996C-NUQ
Universal Door Strike can be used with virtually any cylindrical-locking
system and can be configured for use in wood, aluminum, or metal doors. Included are three different
ANSI-sized faceplates that can be easily installed on the strike to match the door frame type. The strike is
easily field-configurable for fail-safe or fail-secure applications.
Table of Contents:
Introduction ............................................................ 2
Specifications ........................................................ 2
Parts List ................................................................ 2
Installation ............................................................. 2
Measuring the Latch & Center Lines ..................... 3
Mounting the Template .......................................... 3
Preparing the Door Frame ..................................... 4
Mounting the Trim Plate ........................................ 4
Introduction:
Installation:
Operating voltage
12/24 VDC ±15%
Current draw
12VDC 300mA
24VDC 150mA
Operating temperature
32°~120° F (0°~49° C)
Operating humidity
0~85%, non-condensing
Static strength
1,000-lb (4,448N)
Dynamic strength
50ft-lb (68J)
Endurance
250,000 cycles (UL Tested), Level IV
Destructive attack
Level I
Line security
Level I
Standby power
Level I
Specifications:
Note:
Not all parts will be used in every installation.
1.
Select the type of faceplate that will be used. See "Sample Installations," pgs. 5-7. If the door is pre-cut
for a strike, skip to step 6.
2.
Measure and mark the door latch line and the center line of the door. See "Measuring the Latch Line &
Center Lines," pg. 3.
3.
Apply the included stick-on template to the door frame. See "Mounting the Template," pg. 3.
4.
Prepare the door frame for installation and mount the trim plate if needed. See "Preparing the Door
Frame" and "Mounting the Trim Plate," pg. 4.
5.
If the door frame material is unsuitable for mounting the strike directly, use the included mounting tabs
and small black anchor nuts for installation. This is recommended for aluminum door frames. See
"Mounting the Strike Using Mounting Tabs," pg. 4.
6.
Program for either fail-safe or fail-secure operation. See "Selecting Fail-Secure or Fail-Safe," pg. 4.
7.
Connect to power. See "Wiring Diagram," pg. 8.
Parts List:
Mounting the Strike Using Mounting Tabs ................. 4
Selecting Fail-Secure or Fail-Safe ............................. 4
Sample Installations ............................................... 5~7
Aluminum Door Frame Installation ......................... 5
Hollow Metal Door Frame Installation ..................... 6
Wood Door Frame Installation ................................ 7
Wiring Diagram ........................................................... 8
Troubleshooting ........................................................ 8
Door Strike ......................................................... x 1
Mounting Plates ................................................. x 3
SD-996RA-11Q -
For aluminum door frames
SD-996SS-11Q
-
For hollow metal door frames
SD-996RA-31Q
-
For wood door frames
Mounting template ............................................. x 1
Electrical connectors ......................................... x 2
Trim plate ........................................................... x 1
Trim plate screws .............................................. x 2
Wiring Connectors ............................................. x 2
Mounting tabs .................................................... x 2
Wood screws ..................................................... x 2
Machine screws ................................................. x 4
Machine screws (narrow) .................................. x 2
Phillips screws ................................................... x 2
Black anchor nuts .............................................. x 2