seca serva: Recalibrate scale
E 40
EEPROM data incorrect
Replace electronics
Table 4: Error messages [334|335|382|383|384|385|833|834|835|874|875|876|877|878|952|956]
3.4 Error messages [769|799|780|869|899]
If a malfunction or defect occurs during operation of the scale, it is shown on the display
as an error message. Error messages are displayed in the following form:
"E mm.xx"
E:
Error
mm: Number of the module reporting the error
(10 = weight calculation, 11 = electronic display)
xx:
Error number (Table 5)
Displayed Cause
Remedy
E XX. 11
Load cell defective, supply
leads damaged or electronics
defective
Diagnosis with seca serva:
Check load cell connections
Poss. replace load cell or
electronics
Check preload on scale
E XX.12
Preload too great, load cells
damaged or electronics
defective
Diagnosis with seca serva:
Poss. replace load cell or
electronics
E XX.13
Limit for automatic zero tracking
reached
Place load of >0.5d/s on scale