background image

 

13 

13. General Disposal  

 

This product may not be disposed of with household waste. At the end of its useful life, 
the product must be returned to a point of acceptance for the recycling of electric and 
electronic device. Please ask your local municipality for the point of acceptance! As the 
devices contain valuable recyclable materials, they should be sent for recycling, in order 

not to harm the environment or human health from uncontrolled waste disposal. 

 

14. CE Declaration of Conformity 

 

This product has been prepared according to the listed below guidelines: 
 

 

Essential 
characteristics

 

Perfomance 

Harmonised technical specification 

Nominal activation 
conditions/ Sensitivity. 
Response delay 
(response time) and 
Performance under fire 
conditions

 

 
 

PASS

 

 
 
 
 
 
 

 
 
 
 
 

EN 14604:2005/AC:2008

 

 
Operational reliability

 

 

PASS

 

Tolerance to supply 
voltage

 

 

PASS

 

Durability of operational 
reliability and response 
delay; temperature 
resistance

 

 

 

PASS

 

Durability of operational 
reliability; vibration 
resistance

 

 

PASS

 

Durability of operational 
reliability; humidity 
resistance

 

 

PASS

 

Durability of operational 

 

 

EMC 2014/30/EU 

 

 

RoHS 2011/65/EU 

 

RED 2014/53/EU 

 
Siterwell Electronics Co., Limited 
No.666 Qingfeng Road, Jiangbei District, 
Ningbo, Zhejiang Province, 315034 China

 

Summary of Contents for GS558

Page 1: ...tup 5 3 1 Activation the wireless smoke alarm detector 6 3 2 Function control 6 3 3 Temporary muting the alarm 7 3 4 Recurrent self test of the wireless smoke alarm detector on its function 7 4 Networking of smoke alarms among each other 7 5 Installation 8 6 Replacing batteries 9 7 Notes to the use of batteries 10 8 Technical Data 10 9 Reasons for triggering a false alarm 11 10 Behavior in case of...

Page 2: ...detector identifies the smoke and not the flame of a fire The smoke alarm detector is also reacting from a heat of 54 to 70 C This wireless smoke alarm detector type GS558 may only be used in private rooms After a maximum of 10 years as well this device must be replaced The wireless smoke alarm detector can detect a fire early by recognizing the smoke or the burning articles This device is not sui...

Page 3: ...age it The conversion of this product is not allowed Another use than described may damage the product This product is only suited for indoor use and not for outdoor use Protect it against humidity and moisture splashing or dripping Damaged wireless smoke alarm detectors must be replaced immediately 2 Mounting location in rooms of the wireless smoke alarm detectors 2 1 Wireless smoke alarm detecto...

Page 4: ...g of the room and spread horizontally The wireless smoke alarm detector should be placed possible so that this is at least 50cm from the side wall and 61cm mounted away from the corner of the room see Figure 3 Figure 3 Mounting the wireless smoke alarm detector on the ceiling On ceiling beams which are thicker than 20 cm no installation of wireless smoke alarm detector should be done A minimum dis...

Page 5: ...ry dusty rooms With A shaped roofs the wireless smoke alarm detectors may not be mounted at the highest point Rooms having a room temperature of below 5 C or above 45 C In caravan or similar rooms In these living areas the attachment to the inside of parts are advised The air in the upper part of these areas as well as the ceiling is strongly warmed up by intense solar irradiation This can result ...

Page 6: ...ss smoke alarm detector 3 2 Function control The TEST button is used to check the function of the wireless smoke alarm detector After pressing the key a very loud alarm will sound Keep the wireless smoke alarm detector at least an arm s length away from your body while pressing the TEST button Afterwards the alarm sounds briefly 3 times and the LED flashes In this case the function of the electron...

Page 7: ...here are a total of over 60 000 encodings If a wireless smoke alarm detector is connected to another one it will accept the code of the other An already networked wireless smoke alarm detector which is to be connected to a new wireless smoke alarm detector takes over the code of the new device Please note that wireless smoke alarm detector may only be interlinked within an apartment or a family ho...

Page 8: ...re within radio range also begin to beep This is a test alarm which turns itself off after about a minute If you want to terminate the test alarm prematurely briefly press the TEST button of each wireless smoke alarm detector RESET Mode To assign a new random code you must switch the wireless smoke alarm detector into the RESET mode Press the TEST button for approx 16 seconds until the LED flashes...

Page 9: ...30 second intervals for 30 days With this it points out that the battery must be changed Additionally the LED flashes The wireless smoke alarm detector is still fully functional at this time However it is recommended to replace the battery as soon as the wireless smoke alarm detector is warning about the empty state of the battery Please always replace the battery with an identical battery type wh...

Page 10: ...s are not to be re charged New batteries should not be used together with used batteries Please always use batteries with the same type Please always pay attention to the correct polarity when inserting the battery The connection terminals never short circuit Throw batteries never into the fire Keep batteries away from children and animals Please make sure that the batteries are not swallowed espe...

Page 11: ...ure is the creation of an escape plan and the subsequent discussion with your roommates or your family If the fire cannot be extinguished with a fire extinguisher or a fire blanket by yourself then leave the house immediately Do not waste time to put clothes on or by transportation of personal objects because every second counts After leaving the house please inform the fire department immediately...

Page 12: ...turn batteries and or accumulators gratuitous in the sales point or in their direct vicinity for example at municipal collection points and trade Otherwise you can also return the batteries and or accumulators by post to us SEBSON Gernotstr 17 44319 Dortmund Germany Batteries and or accumulators which contain harmful substances are marked with the symbol of a crossed out waste bin and may not be d...

Page 13: ...pared according to the listed below guidelines Essential characteristics Perfomance Harmonised technical specification Nominal activation conditions Sensitivity Response delay response time and Performance under fire conditions PASS EN 14604 2005 AC 2008 Operational reliability PASS Tolerance to supply voltage PASS Durability of operational reliability and response delay temperature resistance PAS...

Page 14: ...ity of operational reliability electrical stability PASS The declaration of performance for this product can be found under the following link www sebson de DOP_GS558_EN_N pdf SEBSON Sebastian Sonntag Gernotstr 17 44319 Dortmund Germany www sebson de ...

Reviews: