TROUBLE-SHOOTING GUIDE

13

PROBLEM

Does not turn on

Bag full or clog light on
Bag full or clog light on
& machine shuts off

Does not pick up

Filter bag door won’t
fully close

REASON

1. Telescopic tube not inserted properly.

2. Not plugged into working outlet.

3. Cable worn.

4. K3: The power control slider

switch is set to “0” (“off” position).

1. Bag full.

2. Clog in hose, telescopic tube,

brush or head, or entrance to

filter bag.

3. Micro-hygiene filter dirty.

4. Exhaust filter dirty.

1. Hose/handle assembly not

correctly inserted.

2. The suction control dial is rotated

to no suction setting

3. Filter bag cover not closed.

1. Filter bag cover not fully closed.

2. Bag not inserted properly

3. Micro-hygiene filter not properly

inserted.

SOLUTION

1. See page 7.

2. Use another outlet.

3. Replace cable.

4. K3: Set slider switch to “on”

position. See page 9.

1. Replace filter bag. See page 11.

2. See Clog Removal on page 12.

K3 users with clog in power head

attachment: refer to clog removal

in the ET-H or ET-1 owner ’s

manual.

3. Replace micro-hygiene filter.

See page 11.

4. Replace exhaust filter. See page 11.

1. Reinsert hose/handle assembly

making sure that it is lined up

properly and is snapped into

place. See page 7.

2. K2: Rotate suction control

dial to yellow setting. See page 8.

3. See below.

1. Reinsert bag. Lock the cover

down firmly.

2. Reinsert bag. lock the cover

down firmly.

3. Remove the filter bag cover (26) and

make sure the micro-hygiene filter

housing is seated firmly in place

(see pg. 11, figure 18).

Always unplug vacuum from outlet before dismantling any part of the machine!

!

Summary of Contents for AIRBELT K2

Page 1: ...OWNER S MANUAL For Household Use Only...

Page 2: ...t Nozzle 10 The Combination Nozzle 10 The Turbo Nozzle 10 Vacuum Maintenance 11 Changing the Filter Bag 11 Changing the Micro Hygiene Filter 11 Changing the Exhaust Filter 11 Changing the AIRBELT 11 C...

Page 3: ...21 Maintenance and repairs must be done by qualified personnel 22 Use only original SEBO replacement parts 23 Do not use vacuum as a step 24 If vacuum is used on plush carpet or carpet with thick padd...

Page 4: ...FULL OR CLOG light will again illuminate and the machine will shut off This feature prevents damage to the motor due to overheating Incorrect Height Setting or Brush Deterioration Light To ensure opt...

Page 5: ...lable Brushless Cleaning Capability The ET 1 or ET 2 power heads can provide gentle brushless cleaning of delicate rugs or hard floors because the brush roller may be switched off but suc tion will co...

Page 6: ...s The SEBO ET H Power Head 11 3 4 wide 11 1 2 cleaning width Its patented new design offers dual edge cleaning and a manual brush pressure control for opti mal cleaning from one type of flooring to an...

Page 7: ...n all of the heads brush es and power heads To attach the dusting brush clip 27 locate the two raised ridges on the upper end of the telescopic tube 4 just below the handle Push the clip onto the tube...

Page 8: ...ing the cable always switch off and unplug the vacuum Hold the plug while rewinding the cord onto the cord reel Avoid letting the plug whip while rewinding WARNING The quality condition coating textur...

Page 9: ...ad from the upright locked position gently place your foot on the power head for leverage and lower the handle into the operat ing position figure 10b The brush roller will then start spinning The amb...

Page 10: ...is set in the low pile position The rotating brush should be cleaned regularly Remove the Turbo nozzle from the telescopic tube to clean Remove fibers and hair from the brush manually The telescopic...

Page 11: ...ure 16 Figure 18 Figure 19 Always unplug vacuum from outlet before dismantling any part of machine K Filter Set Exhaust Filter and Micro Hygiene Filter Part 6696AM Changing the AIRBELT Figure 19 If da...

Page 12: ...lescopic tube 4 by pushing the tool release button 7 and pulling the tube out Hold the hose upright with one hand blocking the top and switch on the machine If necessary quickly lift your hand on and...

Page 13: ...Micro hygiene filter not properly inserted SOLUTION 1 See page 7 2 Use another outlet 3 Replace cable 4 K3 Set slider switch to on position See page 9 1 Replace filter bag See page 11 2 See Clog Remov...

Page 14: ...otor cover Plug surround Top casing K2 hunter green Release button Exhaust filter cover hunter green On Off knob gray hunter green Casing clip Foam bumper AIRBELT textile citrus incl pos 31 AIRBELT cl...

Page 15: ...ing Seal Motor mounting Motor cover Plug surround Top casing K red Release button Exhaust filter cover red On Off knob gray white Casing clip Foam bumper AIRBELT textile dark gray incl pos 31 AIRBELT...

Page 16: ...l document of proof of purchase and determines the validity of warranty To be certain that your warranty claim can be processed as quickly and efficiently as possible please retain your original purch...

Reviews: