Page 1: ...he direction of movement of the mechanism will be reversed whether engaged in opening or closing operations Step Step Select bridge J1 pos 2 3 with central turned off Using either the radio control CODE led lit or the low tension button panel PUL to operate the gates commands will have the following effect the first command impulse activates the opening mechanism either for the pre set motor opera...
Page 2: ...default is for typical operation with one motor only for example a rolling gate If the mechanism is required to operate two motors simultaneously for example a double gate follow these instructions using the SEL button select the 1 2 Motori led flashing pressing the MODE button will cause the 1 2 MOTORI led to remain on To deactivate this function i e return to default one motor operation follow t...
Page 3: ... T PAUSA Led flashes then press and hold down the MODE button for a period equal to the desired pause interval between closing and opening operations Release the MODE button and the T PAUSA Led will remain on If automatic closing is not required press the SEL button until the T PAUSA Led flashes then press the MODE button for less than one second and the T PAUSA Led will turn off 10 GATE OPENING D...
Page 4: ...7 Rev 1 3 12 04 ...