6
Rev. 1.3 12/04
SEL button until the INB. CMD. AP. Led flashes. Pressing the
MODE button will cause the INB. CMD. AP. Led to turn off.
5) PEDESTRIAN PASSAGE / SINGLE GATE OPERATION
The control board is supplied with the Pedestrian passage
function activated (PED./ANTA S. Led off). To activate single
gate operation, follow these instructions: press the SEL button
until the PED/ANTA S. Led flashes then press the MODE
button and the PED/ANTA S. Led will remain lit. To deactivate
this function, follow these instructions: press the SEL button
until the PED/ANTA S. Led flashes. Pressing the MODE button
will cause the PED/ANTA S. Led to turn off.
6) KICKBACK
The control board is supplied with the kickback deactivated
(COLPO ARIETE Led off). To activate this function, follow these
instructions: press the SEL button until the COLPO ARIETE
Led flashes then press the MODE button and the COLPO
ARIETE Led will remain lit. With this function activated, each
time the mechanism activates the opening cycle it will
automatically perform a short closing cycle. To deactivate this
function, follow these instructions: press the SEL button until
the COLPO ARIETE Led flashes. Pressing the MODE button
will cause the COLPO ARIETE Led to turn off.
7) PRE-FLASHING
The control board is supplied with the pre-flash deactivated
(PRELAMP Led off). To activate this function, follow these
instructions: press the SEL button until the PRELAMP Led
flashes then press the MODE button and the PRELAMP Led
will remain lit. With this function activated, each time the
mechanism is activated the light will flash for three seconds
before any movement. To deactivate this function, follow these
instructions: press the SEL button until the PRELAMP Led
flashes. Pressing the MODE button will cause the PRELAMP
Led to turn off.
8) T. MOT.
: Maximum programmed operating interval 4 min
The command board is supplied with a pre-set motor
operating interval of 30 seconds.
Before resetting the motor operating interval the gate must be
closed. The procedure is as follows: press the SEL button
until the T. MOT. Led flashes, then press and hold down the
MODE button. The gate will start to open, once it reaches the
desired position, release the MODE button and the T. MOT.
Led will remain on. If an infinite motor operating interval is
required: press the SEL butto n until the T. MOT. Led flashes,
then press the MODE button for less than one second and the
T. MOT. Led will turn off. If a limit switch is used it is a good
idea to memorise an operating interval slightly longer than
required to activate the limit switch.
9) T. PAUSE
:
Maximum programmed aut. closing 4 minutes
The command board is supplied with automatic closing
(Pause interval of 15 seconds) activated. Before resetting the
pause interval the gate must be closed. The procedure is as
follows: Press the SEL button until the T. PAUSA Led flashes,
then press and hold down the MODE button for a period equal
to the desired pause interval between closing and opening
operations. Release the MODE button and the T. PAUSA Led
will remain on. If automatic closing is not required: press the
SEL button until the T. PAUSA Led flashes, then press the
MODE button for less than one second and the T. PAUSA Led
will turn off.
10) GATE OPENING DELAY
:
Maximum programmed delay 30
seconds
If 2 motor operation is selected the command board has a
pre-set gate opening delay (motor 2 will activate 3 seconds
after motor 1). Before resetting the delay interval the gate must
be closed. The procedure is as follows: press the SEL button
until the RIT. ANTE AP Led flashes, then press and hold down
the MODE button for a period equal to the desired interval of
between the activation of the two motors. Release the MODE
button and the RIT. ANTE AP Led will remain on. If an opening
delay is not required: press the SEL button until the RIT. ANTE
AP Led flashes, then press the MODE button for less than one
second and the RIT. ANTE AP Led will turn off.
11) GATE CLOSING DELAY
:
Maximum programmed delay 30
seconds
If 2 motor operation is selected the command board has a
pre-set gate closing delay. (motor 1 will activate 3 seconds
after motor 2) Before resetting the delay interval the gate must
be closed. The procedure is as follows: Press the SEL button
until the RIT. ANTE CH Led flashes, then press and hold down
the MODE button for a period equal to the desired interval of
between the activation of the two motors. Release the MODE
button and the RIT. ANTE CH Led will remain on. If a closing
delay is not required: Press the SEL button until the RIT. ANTE
CH Led flashes, then press the MODE button for less than
one second and the RIT. ANTE CH Led will turn off.
PROGRAMME RESET (LED 1…11)
If it is necessary to reset the programme board to its default
values, that is, as supplied by the factory; press both the SEL
and MODE buttons together. All the RED Led will flash once.
12) POWER
The POWER led indicates that the mains power is connected.
I
MPORTANT NOTES FOR THE INSTALLER
−
In order for the receiving part of the radio to function
correctly, in cases where two or more centres are used, it is
advisable to install them at a distance of at least 3 meters
from each other.
−
The electronic exchange offers no type of separation
device and it will therefore be necessary for the fitter to
install one beforehand.
−
The fixing of the electricity supply cables and their
connection, must be guaranteed by means of the
assembly of cable presses.
D
ECLARATION OF
C
ONFORMITY
SEAV s.r.l. declares that the products
Electronic panel LG 2100 – LRS 2100 SET
are conformant to all of the requirements laid out in the EC
directive number: 99/5 which are based on the following
standards:
EN 301 489-1/3 - EN 300 220-1/3 - EN 60335-1.
The sample which has been tested meets the essential
requirements which have been specified above, on the
basis of the results of the tests performed.
Osimo, 26/03/01