Seav LRX 2100 Quick Start Manual Download Page 3

 

Rev. 1.3  12/04 

SEL button until the INB. CMD. AP. Led flashes. Pressing the 
MODE button will cause the  INB. CMD. AP. Led to turn off. 

5) PEDESTRIAN PASSAGE / SINGLE GATE OPERATION 

The control board is supplied with the Pedestrian passage 
function activated (PED./ANTA S. Led off). To activate single 
gate operation, follow these instructions: press the SEL button 
until the PED/ANTA S. Led flashes then press the MODE 
button and the PED/ANTA S. Led will remain lit. To deactivate 
this function, follow these instructions: press the SEL button 
until the PED/ANTA S. Led flashes. Pressing the MODE button 
will cause the PED/ANTA S. Led to turn off. 

6) KICKBACK 

The control board is supplied with the kickback deactivated 
(COLPO ARIETE Led off). To activate this function, follow these 
instructions: press  the SEL button until the COLPO ARIETE 
Led flashes then press the MODE button and the COLPO 
ARIETE Led will remain lit. With this function activated, each 
time the mechanism activates the opening cycle it will 
automatically perform a short closing cycle. To  deactivate this 
function, follow these instructions: press the SEL button until 
the COLPO ARIETE Led flashes. Pressing the MODE button 
will cause the COLPO ARIETE Led to turn off. 

7) PRE-FLASHING 

The control board is supplied with the pre-flash deactivated 
(PRELAMP Led off). To activate this function, follow these 
instructions: press the SEL button until the PRELAMP Led 
flashes then press the MODE button and the PRELAMP Led 
will remain lit. With this function activated, each time the 
mechanism is activated the light will flash for three seconds 
before any movement. To deactivate this function, follow these 
instructions: press the SEL button until the PRELAMP Led 
flashes. Pressing the MODE button will cause the PRELAMP 
Led to turn off. 

8) T. MOT.

: Maximum programmed operating interval 4 min

 

The command board is supplied with a pre-set motor 
operating interval of 30 seconds. 
Before resetting the motor operating interval the gate must be 
closed. The procedure is as follows: press the SEL button 
until the T. MOT. Led flashes, then press and hold down the 
MODE button. The gate will start to open, once it reaches the 
desired position, release the MODE button and the T. MOT. 
Led will remain on. If an infinite motor operating interval is 
required: press the SEL butto n until the T. MOT. Led flashes, 
then press the MODE button for less than one second and the 
T. MOT. Led will turn off. If a limit switch is used it is a good 
idea to memorise an operating interval slightly longer than 
required to activate the limit switch. 

9) T. PAUSE

:

 

Maximum programmed aut. closing 4 minutes  

The command board is supplied with automatic closing 
(Pause interval of 15 seconds) activated. Before resetting the 
pause interval the gate must be closed. The procedure is as 
follows: Press the SEL button until the T. PAUSA Led flashes, 
then press and hold down the MODE button for a period equal 
to the desired pause interval between closing and opening 
operations. Release the MODE button and the T. PAUSA Led 
will remain on. If automatic closing is not required: press the 
SEL button until the T. PAUSA Led flashes, then press the 
MODE button for less than one second and the T. PAUSA Led 
will turn off. 

10) GATE OPENING DELAY

:

 

Maximum programmed delay 30 

seconds  
If 2 motor operation is selected the command board has a 
pre-set gate opening delay (motor 2 will activate 3 seconds 

after motor 1). Before resetting the delay interval the gate must 
be closed. The procedure is as follows: press the SEL button 
until the RIT. ANTE AP Led flashes, then press and hold down 
the MODE button for a period equal to the desired interval of 
between the activation of the two motors. Release the MODE 
button and the RIT. ANTE AP Led will remain on. If an opening 
delay is not required: press the SEL button until the RIT. ANTE 
AP Led flashes, then press the MODE button for less than one 
second and the RIT. ANTE AP Led will turn off. 

11) GATE CLOSING DELAY

:

 

Maximum programmed delay 30 

seconds  
If 2 motor operation is selected the command board has a 
pre-set gate closing delay. (motor 1 will activate 3 seconds 
after motor 2) Before resetting the delay interval the gate must 
be closed. The procedure is as follows: Press the SEL button 
until the RIT. ANTE CH Led flashes, then press and hold down 
the MODE button for a period equal to the desired interval of 
between the activation of the two motors. Release the MODE 
button and the RIT. ANTE CH Led will remain on. If a closing 
delay is not required: Press the SEL button until the RIT. ANTE 
CH Led flashes, then press the MODE button for less  than 
one second and the RIT. ANTE CH Led will turn off. 

PROGRAMME RESET (LED 1…11) 

If it is necessary to reset the programme board to its default 
values, that is, as supplied by the factory; press both the SEL 
and MODE buttons together. All the RED Led will flash once. 

12) POWER 

The POWER led indicates that the mains power is connected. 

I

MPORTANT NOTES FOR THE INSTALLER

 

 

In order for the receiving part of the radio to function 

correctly, in cases where two or more centres are used, it is 
advisable to install them at a distance of at least 3 meters 
from each other. 

 

The electronic exchange offers no type of separation 

device and it will therefore be necessary for the fitter to 
install one beforehand. 

 

The fixing of the electricity supply cables and their 

connection, must be guaranteed by means of the 
assembly of cable presses.

 

 

D

ECLARATION OF 

C

ONFORMITY 

SEAV s.r.l. declares that the products  

Electronic panel LG 2100 – LRS 2100 SET 

are conformant to all of the requirements laid out in the EC 
directive number: 99/5 which are based on the following 
standards: 

         EN 301 489-1/3 - EN 300 220-1/3 - EN 60335-1. 
 
The sample which has been tested meets the essential 
requirements which have been specified above, on the 
basis of the results of the tests performed. 

Osimo, 26/03/01

 

 

Reviews: