Functions with one or two remote control commands
It is possible to memorise one or two remote control commands
during the programming stage. One code can be used for a
cyclical function (raising/lowering), whilst two different codes
allows different commands, the first for raising and the second
for lowering.
Programming: The transmission code is programmed in the
following manner: press the SEL button until the LED CODE
flashes, immediately transmit the pre-selected code with the
desired remote control, as soon as the LED CODE begins to
flash rapidly send the second code to be memorised, when the
LED CODE remains lit, the programming is complete. If the
second code is not sent within 10 seconds the control unit will
exit the programming phase and select the function with only
one code of the remote control. When 60 codes have been
stored all 4 LEDs will flash, indicating that no other codes can
be stored.
Programming through Radio command:
This procedure, consents to enable the programming, without
direct intervention of the SEL task on the panel, but executing
the operation at a distance, allows the programming of
transmission codes without the having to use the SEL button
on the central direct.
The ability of programming is executed in the following manner:
send in a continuous manner for max. 10 seconds the codes of
the radio command previously memorised, at the same time
the panel will enter into programming mode as explained
above.
Ability of programming through Radio command:
The panel is furnished by the builder with the radio command
disabled, if you wish to enable the function, proceed in the
following manner: the panel board is powered by an output of
230VAC, keeping the SELL task pressed, at the same time you
will obtain a brief flashing of all the Leeds and the programming
will be complete.
If you wish to disable the function previously enabled, repeat
the operation or follow the RESET procedure.
Cancellation: To cancel all stored codes press the SEL button
and LED CODE will start to flash. Then press the SET button.
The procedure is now complete and LED CODE will stop
flashing.
2) FLASHING / COURTESY LIGHT: (Selection of the flashing
light or the courtesy light)
The central has a 230 Vac output, for connection to a flashing
light or a courtesy light. The central is supplied by the
manufacturer with the flashing function predisposed.
If you wish to set up the courtesy light function, proceed as
follows:
Go to the SEL button, when the LED LAMP / CORT light
flashes
then
press
SET,
at
the
same
time
the
LED/LAMP/CORT light will light up permanently. Repeat the
operation if you wish to put the previous configuration back into
operation.
Flashing function: The 230 Vac output will be activated each
time that the automation is moving, for the duration of the motor
time. In cases where the time of pause is memorised, the
flashing light will also be active during the pause.
Functioning of the Courtesy light: The 230 Vac output will be
activated for the entire duration of 3 minutes, each time that an
ascent command is given.
3) T. MOT: (Programming the motor operating time max. 4
minutes)
The control unit is factory supplied with a working time motor
predefined equal to 30 sec.
If a reprogramming of the motor operating time is needed, it
must be effected through the closed frame in the following
manner: set the SEL button on the T. MOT flashing led, then
continuously press the SET button, the rolling shutter will start
the opening; when you have reached the required height,
release the SET button key and at the same time the motor
time storage will be completed and the T. MOT. Led will remain
lit and fixed. If you want an infinite motor time, using the SEL
task when the Led T.MOT is flashing press for less than 1
second the SET button, at the same time the Led will shut off
and the operation will be completed. It is advisable to memorise
a time that is a few seconds longer after the frame has reached
the end.
4) T. PAUSE:
(Maximum programmed automatic wing closing 4
minutes)
The manufacturer furnishes the board with an automatic
closure (pause time equal to 15 sec.). If a reprogramming of
the automatic closing time is needed, it must be effected in
closed frame in the following manner: press the SEL button
until the T. PAUSE led flashes, then press and hold down the
SET button for a period equal to the desired pause interval
between closing and opening operations, at the expiry of the
desired time leave the SET button, at the same time the
memorisation of automatic closing time will be determined and
the Led T. PAUSE will be lit.
If decided not to have the automatic closing, take position on
the flash of the Led T. PAUSE after press the SET task for less
than a second, at the same time the Led will shut off and the
operation will be concluded.
RESET :
If it necessary to reset the program board to its default values,
that is with no memorised data, press both SEL and SET
buttons continuously, all the RED LEDs will flash at once
DIAGNOSTIC :
In correspondence to all input commands in low tension, the
centre uses Led signals for every input command to allow rapid
status control. Logic of function: a lit Led means input closed,
an unlit light means input open.
:
Electronic exchange:
LG 2035R - LRS 2035R - LRS 2035R SET
comply with the requirements of Directives R&TTE
99/5/EC, EMC 2004/108/EC, LVD 2006/95/EC.
Rev. 1.6 del 15-05-12