background image

flash  alternatively),  using  the  “SEL”  button  navigate  to  PAUSA 
LED when flashing and press the “SET” button: at that moment 
the  PAUSA  LED  lights  up  in  a  constant  manner  and 
programming  is  completed.  In  this  mode  the  control  unit  will 
modify the safety device intervention as follows: Input closed = 
error  status;  input  =  8K2 

,  normal  safety  device  operation; 

input open = safety device intervention. 

 

 
F) SEL DS1 (DS3 intervention operating mode):
 
The  control  unit  is  supplied  by  the  manufacturer  with  the  DS3 
safety  device  intervention  mode  operating  as  follows:  Input 
closed  =  safety  device  intervention;  input  =  8K2 

,  normal 

safety device operation; input open = error status. If you wish to 
modify the safety device intervention mode, proceed as follows: 
check that the extended menu is enabled (DS2 and DS3 LEDs 
flash  alternatively),  using  the  “SEL”  button  navigate  to  PAUSA 
LED when flashing and press the “SET” button: at that moment 
the  PAUSA  LED  lights  up  in  a  constant  manner  and 
programming  is  completed.  In  this  mode  the  control  unit  will 
modify the safety device intervention as follows: Input closed = 
error  status;  input  =  8K2 

,  normal  safety  device  operation; 

input open = safety device intervention. 

 

 
RESET: 
To  restore  the  default  configuration,  press  the  SEL  and  SET 
buttons  simultaneously,  all  RED  LEDs  will  light  up  and  then 
switch off.  
 
ERROR INDICATION: 

 

The  control unit enables errors or malfunctions to be identified 
using Software tests. If there are errors or malfunctions on the 
Input/Output devices, the control unit will indicate the status by 
alternately  activating  and  deactivating  (for  5  seconds  a  time, 
and  for  a  maximum  period  of  1  minute)  the  230  V  a/c  500  W 
output for the connection of the flashing beacon or the courtesy 
light. 

 

This guarantees monitoring of breakdowns which complies with 
Category  2  of  EN  954-1.  Whenever  one  of  these  malfunctions 
occurs a qualified professional should be called to fix it. 
 
Test Driver Motor:

 

The  control  unit  is  fitted  with  two  drivers  used  to  control  the 
motor.  If  there  is  a  malfunction,  the control unit will not enable 
motion  of  the  shutter  and  will  indicate  the  test  failure  visually 
through  the  simultaneous  flashing  of  all  LEDs  except  the  T. 
MOT  LED;  which  will  remain  lit  in  a  constant  manner.    We 
recommend  a  qualified  technician  is  contacted  immediately  in 
order  to  resolve  the  problem.  Once  the  correct  operating 
conditions  are  restored  the  control  unit  may  be  switched  on 
again. The error status is reset and the control unit is ready to 
operate normally.

 

 
 
 
DS1 - DS2 - DS3 safety device test:

 

The  control  unit  is  designed  for  connection  to  safety  devices 
(see  Notes  for  the  Installer  section)  which  comply  with  point 
5.1.1.6 of regulation EN 12453. If there is no connection and/or 
no  operation,  the  control  unit  will  not  enable  motion  and  will 
indicate  the  test  failure  visually  through  the  simultaneous 
flashing  of  all  LEDs  except  the  DS1,  DS2  or  DS3  LED, 
depending  on  which  device  generated  the  breakdown 
indication.

 

After  the  malfunction  has  been  identified,  the  control  unit 
makes it possible to monitor only the opening movements when 
a  user  is  present,  either  using  the  push-button  station  or  the 
radio  control  (when  operating  via  2-button  radio  control  the 
button  corresponding  to the closing movement is disabled and 
when operating via 3-button radio control the closing movement 
and  Stop  buttons  are  disabled).  We  recommend  a  qualified 
technician  is  contacted  immediately  in  order  to  resolve  the 
problem. Once the correct operating conditions are restored the 

control unit may be switched on again. The error status is reset 
and the control unit is ready to operate normally.

 

 
HARDWARE DIAGNOSTICS: 

 

 
PUL command test:

 

The  control  unit  is  fitted  with  a  Red  LED  for  every  low  voltage 
PUL command so that its status may be monitored quickly. 

 

Operation principle: LED on = input closed, LED off 
= input open. 

 

DS1 safety device test:

 

The  control  unit is fitted with a Red LED which corresponds to 
the low voltage DS1 safety device input, so that its status may 
be  monitored  quickly.    Operation  principle:  LED  on  =  input 
closed, LED off = input open.

 

 
DS2 - DS3 safety device test:

 

The  control  unit  is  fitted  with  two  indicator  LEDs  (Red  and 
Green)  which  correspond  to  the  low  voltage  DS2  and  DS3 
safety  device  inputs,  so  that  their  status  may  be  monitored 
quickly.  Operation principle: Red LED illuminated input closed, 
Green LED illuminated input closed with balanced device (8.2K 
ohm type), Red and Green LEDs switched off input open.

 

 
 
 
 
 

Summary of Contents for LRS 2197

Page 1: ...and the button will need to be pressed again to reactivate the motor in the opposite direction Operation using a 2 button radio control The following type of operation is obtained using a radio control with 2 buttons the first button Up corresponding to the opening movement controls opening until the motor stops running and the second button Down corresponding to the closing movement controls the ...

Page 2: ...tector push button station or 1 button radio control will cause the motor direction to be inverted if operating with a 2 button radio control the button corresponding to opening will cause the motor direction to invert and the closing button is ignored if operating with a radio control in the BeFree series the opening button causes inversion the closing button is ignored and the Stop button causes...

Page 3: ...utton To programme the transmission code remotely proceed as follows send the radio control code continuously for more than 10 seconds the control unit will enter the programming mode as described above for the CODE LED in the main menu The control unit is supplied by the manufacturer with remote programming of the transmission code not enabled to enable the function proceed as follows check that ...

Page 4: ...ugh the simultaneous flashing of all LEDs except the T MOT LED which will remain lit in a constant manner We recommend a qualified technician is contacted immediately in order to resolve the problem Once the correct operating conditions are restored the control unit may be switched on again The error status is reset and the control unit is ready to operate normally DS1 DS2 DS3 safety device test T...

Page 5: ...g parts where an individual may become entangled so that it is impossible for anyone to be pushed or lifted by the door Do not use the control unit in conjunction with exit door sites or emergency exit routes We advise that you also take note of the following recommendations Before shutter automation it is necessary to check the product is in good condition and that it complies with EN 12604 and t...

Page 6: ...is instruction manual in a safe place and adhere to the important safety instructions contained within it Non adherence to these instructions may lead to property damage and serious accidents Examine the system frequently to check for any signs of damage Do not use the device if it needs to be repaired Rev 2 2 dated 02 04 07 The below products Electronic Control Unit LG 2197 LRS 2197 LRS 2197 SET ...