11
button, LED CODE starts lighting, in the meanwhile send
the transmission Code with the related radio control, at this
point the LED CODE will Stay on the programming will be
completed.
Rule of the first memorized radio control:
In radio controls programming there is the following rule: if
the first Memorized radio control is a Rolling Code one, the
electronic panel will accept only Rolling Code radio con-
trols, with more anti-Intrusion safety; if instead the first
memorized radio control has fixed Code, the receiver will
accept both fixed codes and Rolling Code Radio controls.
Radio control already in memory or incompatible:
It is possible to memorize up to 120 radio controls with
different Codes. In case of programming devices already
in memory or Incompatible, the LED CODE starts flashing
rapidly for some instant, Flaging the impossibility and then
it will return to programming.
Highest number of memorized devices:
It is possible to memorize up to 120 radio controls with dif-
ferent Codes. In case of the hightest number of memorized
devices is Reached, repeating the programming, the elec-
tronic panel flags the Error by the flashing of all the leds save
the LED CODE, which stays Fixed on. After 10 seconds the
electronic panel exits from the Programming mode.
2) CODE ALARM:
Programming of the radio control
for the Activation/deactivation of the alarm system).
The method of programming and cancellation is similar
to the one Described before, but related to LED CODE
ALARM, with the only Difference that it is refered to a
button, related to the radio control for Activation and de-
activation of the alarm system.
Important:
when any Alarm Code was not programmed
(CODE ALARM OFF), the panel does not control connec-
tions and functions Of the Alarm System.
3) LAMP/CORT:
(Selection of the flashing light or the
courtesy light).
The control unit has a 230 Vac output, for connection to a
flashing light or a courtesy light. The control unit is sup-
plied by the manufacturer with the flashing function even
with delay enabled. If you wish to set up the flashing
light function, proceed as follows: use the SEL button to
navigate to the LAMP/CORT LED when flashing and then
press the SET button. The LAMP/CORT button will light
up permanently.
Repeat the operation if you wish to put the previous configu-
ration Back into operation. If you wish to set up the courtesy
light, repeat The operation described above, pressing the
SEL button twice instead of once (the LAMP/CORT LED will
flash rapidly). Repeat the operation if you wish to put the
previous configuration back into Operation.
Flashing Light function even in pause:
the 230 Vac out-
put will be Activated each time that the automation is mov-
ing, for the duration of the motor time. If the pause time is
memorised, the 230Vac output will be active even during the
delay.
Flashing function:
The 230 Vac output will be activated
each time that the automation is moving, for the duration
of the motor time.
Functioning of the Courtesy light:
he 230 Vac output
will be activated for 3 minutes, each time that an opening
command is Given.
Important
:
the flashing/Courtesy light will be acti-
vated at the Same time with the Alarm System, till its
switching off.
4) T. MOT:
(Programming the motor operating time
max. 4 Minutes).
The control unit is factory supplied with a predefined
working time motor equal to 30 sec. If a reprogramming
of the motor operating time is needed, it must be carried
out through the closed frame in the following manner:
use the SEL button to navigate to the T. MOT LED when
flashing, then continuously press the SET button. The
rolling shutter will start the opening.
When you have reached the required height, release the
SET button and at the same time the motor time storage
will be completed and the T. MOT. LED will remain lit
and fixed.
5) T. PAUSE:
(Maximum programmed automatic clos-
ing 4 minutes.)
The manufacturer furnishes the control unit with an
automatic closure (pause time equal to 15 sec.). If a re-
programming of the automatic closing time is needed,
it must be carried out through the closed frame in the
following manner: use the SEL button to navigate to the
T. PAUSE LED when flashing. Then press and hold down
the SET button for a period equal to the Desired pause
interval between closing and opening operations. At
expiration of the desired time release the SET button.
At the same time the memorisation of automatic clos-
ing time will be determined and the T. PAUSE LED will
remain lit.
If you do not want automatic closing, take position on
the T. PAUSE LED when flashing. Then press the SET
button for lessthan a second. At the same time the LED
will shut off and the operation will be concluded.