D) CODE M4
(Programming the start-up delay time):
The control unit allows you to program a start-up delay time for
the 4 motors; this prevents other interconnected sets of 4 mo-
tors from starting up simultaneously. The control unit is provid-
ed without start-up delay time for the 4 motors; to program a
start-up delay time of between 1 and 120 seconds, proceed as
follows: enable the extended menu (the SUN and RAIN LEDs
will flash to confirm this), use the SEL key to navigate to the
CODE M4 LED, then press the SET key for the required delay
time; as soon as you release the key, the M4 CODE LED
switches on permanently and programming is complete. Simply
repeat this procedure to make any changes to the configura-
tion.
E) SENS. CODE (Line Sensor Test):
The control unit allows you to check operation of the connected
sensors and correct movement. You are advised to install the
blind with it half open to check the confirmation movements
during the test. Make sure you disable the Line Sensor Test
after checking the sensors’ operation.
Anemometer test:
turn the blades manually; the control unit
will raise the blind for 5 seconds.
Sun sensor test:
expose the Sun Sensor to the sun or light
source; the control unit switches on the SUN LED and lowers
the blind for 5 seconds. Cover the Sun Sensor and the control
unit will switch off the SUN LED and raise the blind for 5 sec-
onds.
Rain sensor test:
dampen the sensitive part of the Rain Sen-
sor; the control unit will switch on the RAIN LED and raise the
blind for 5 seconds. At the end of the test, make sure you dry
off the sensitive part of the rain sensor before using the control
unit in normal operating mode.
Programming:
The control unit comes with a Line Sensor Test
disabled. If you wish to enable the Line Sensor Test, proceed
as follows: enable the extended menu (the SUN and RAIN
LEDs will flash to confirm this); use the SEL key to navigate to
the SENSOR CODE LED and then press the SET key; at the
same time, the SENSOR CODE LED switches on permanently
and programming is complete. Repeat this procedure to restore
the initial configuration.
Important:
Wireless Sensor test instructions are given in the
Wireless Sensor manual.
F) T. MOT. (Automatic Movement Lock):
The control unit allows you to lock automatic movement (Up-
ward or downward movement of the blind controlled by the Sun
Sensor command or function of the Automatic Sensors); in this
way, the control unit temporarily blocks automatic motion when
a stop command is given during movement until the next rais-
ing or lowering command. The control unit comes with the Au-
tomatic Movement Lock disabled; to enable this function, pro-
ceed as follows: enable the extended menu (the SUN and
RAIN LEDs flash to confirm this), press the SEL key until the
T.MOT LED flashes, then press the SET key; at the same time
the T.MOT LED switches on permanently and programming is
complete. Repeat this procedure to restore the previous config-
uration.
G) WIND SPEED (Safety Upward Movement) :
The control unit comes with the Safety Upward Movement dis-
abled; to enable this function, so that after 12 hours of the Wind
Sensor being inactive the control unit automatically executes
the safety upward movement, proceed as follows: enable the
extended menu (the SUN and RAIN LED will flash to confirm
this), press the SEL key until the WIND SPEED LED flashes,
then press the SET key; at the same time the WIND SPEED
LED switches on permanently and programming is complete.
Repeat this procedure to restore the previous configuration.
H) SUN SENSOR (Sun sensor control inversion):
The control unit comes with the Sun control = Downward
movement control association, so the sensor controls the
downward movement of the blind when it detects the sun. If you
wish the sun sensor to control the upward movement of the
blind when it detects the sun, proceed as follows: enable the
extended menu (the SUN and RAIN LEDs flash to confirm this),
press the SEL key until the SUN SENSOR LED flashes, then
press the SET key; at the same time the SUN SENSOR LED
switches on permanently and programming is complete.
Repeat this procedure to restore the previous configuration.
I) RAIN SENSOR (Rain sensor control inversion):
The control unit comes with the Rain control = Upward move-
ment control association, so the sensor controls the upward
movement of the shutter when it detects the sun. If you wish
the rain sensor to control the downward movement of the shut-
ter when it detects the rain, proceed as follows: enable the ex-
tended menu (the SUN and RAIN LEDs flash to confirm this),
press the SEL key until the RAIN SENSOR LED flashes, then
press the SET key; at the same time the RAIN SENSOR LED
switches on permanently and programming is complete.
Repeat this procedure to restore the previous configuration.
R
ESET
If you need to restore the control unit’s default settings, press
the SEL and SET keys together to switch on all the indicator
LEDs at the same time and then switch them off again immedi-
ately.
Summary of Contents for 93070000
Page 7: ...7 Rev 3 0 13 06 16 ...
Page 13: ...13 Rev 3 0 13 06 16 ...
Page 20: ...20 Rev 3 0 13 06 16 ...
Page 27: ...27 Rev 3 0 13 06 16 ...
Page 34: ...34 Rev 3 0 13 06 16 ...
Page 41: ...41 Rev 3 0 13 06 16 ...
Page 48: ...48 Rev 3 0 13 06 16 ...
Page 54: ...54 Rev 3 0 13 06 16 ...
Page 61: ...61 Rev 3 0 13 06 16 ...