Care and Maintenance

To get the most out of your SeaSucker rack, inspect it regularly and 
store it with the vacuum mounts’ protective covers on. Check that all 
screws  are  securely  tightened,  including  the  screws  attaching  the 
vacuum  pads  to  the  SeaSucker  housing,  the  screws  attaching  the 
SeaSuckers to the rack platform or bars. 

Clean the vacuum cups before each use with a sponge or soft cloth, 
mild  dish  soap  and  water.  Do  not  use  harsh  solvents  or  abrasive 
cleaning  pads.  Make  sure  there  is  no  dirt  or  debris  on  the  sealing 
edge  (the  bottom  outside  edge)  of  the  vacuum  pad.  Inspect  the 
sealing  edge  for  stiffness,  cracks,  roughness,  or  cuts  –  a  cut  will 
allow air to leak under the cup and will prevent your SeaSucker from 
holding vacuum. A   damaged vacuum pad should be replaced. One 
replacement  SeaSucker  comes  with  your  rack.  Additional 
replacement SeaSuckers, vacuum pads, and vacuum pumps can be 
purchased  on-line  at

 

www.seasucker.com

 

in  the  Replacement  Parts 

section of our on-line store.

The  vacuum  pump  should  be  cleaned  regularly. To  clean  the  pump, 
pull the plunger straight out of the pump cylinder. Clean the inside of 
the cylinder with dish soap and a soft cloth or paper towel. Make sure 
to dry out the cylinder – water left in the cylinder can cause the pump 
to  make  a  popping  noise  when  pumped  and  may  interfere  with  the 
check-valve function of the pump.

The  plunger  should  be  wiped  clean  and  the  black  rubber  gasket  at 
the tip of the plunger should be re-lubed with a thin layer of silicone-
based gel lubricant, such as the Lube Tube that came with your rack. 
Additional  tubes  of  Lube  Tube  can  be  found  on-line  in  the 
Replacement  Parts  section  at

 

www.seasucker.com.  After  cleaning, 

push the plunger back into the cylinder and pump it several times to 
seat it properly and distribute the lubricant.

Repair and Replacement

Products  with  non-warrantable  damage  or  products  that  are  no 
longer within the warranty period may still be repaired or replaced at 
your  expense.  Discounted  replacement  parts,  including  vacuum 
pads, pumps, fork mounts and hardware, can be found on-line in the 
Replacement  Parts  section  of  SeaSucker’s  on-line  store  at 
www.seasucker.com.

Warranty

SeaSucker  offers  a  lifetime,  non-transferable  warranty  covering 
defects  in  materials  and  workmanship.  Defective  products  can  be 
returned  to  SeaSucker  for  replacement  or  repair  (at  SeaSucker’s 
option). Warranty claims must be accompanied by a sales receipt or 
other proof of purchase document. The cost of transportation to and 
from SeaSucker for the repair or replacement of any defective part or 
accessory  is  not  covered  by  this  warranty  and  is  to  be  paid  by  the 
owner.  This  warranty  does  not  apply  to  damage  or  failure  resulting 
from  normal  use,  routine  wear  and  tear,  lack  of  maintenance,  user 
error,  alteration  of  the  product,  accidents,  abuse,  or  neglect.  This 
warranty  is  given  in  lieu  of  all  other  written  or  oral  warranties, 
express  or  implied,  including  without  limitation  implied  warranties  of 
merchantability  and  fitness  for  a  particular  purpose,  and  are  limited 
to  the  duration  and  specifications  of  this  warranty.  SeaSucker’s 
liability  for  any  damages  relating  to  any  allegedly  defective  product, 
whether  arising  from  the  use  or  the  inability  to  use  the  product  and 
whether  claimed  under  tort,  contract  or  any  other  legal  theory,  shall 
be  limited  to  the  actual  price  paid  for  such  product  and  shall  in  no 
event  include  loss  of  use,  loss  of  time,  incidental,  consequential, 
special, or indirect damages of any kind, even if SeaSucker is aware 
of the possibility of such damages, to the full extent as such may be 
disclaimed by law. 

Problem

What Might Be Wrong

How To Fix It

Slow 

Leakage

Dry mounting surface  

or vacuum pad

Moisten the mounting surface  

or the vacuum pad

Nicks or cuts on vacuum pad

Replace the vacuum pad

Dirt in pump

Clean and re-lube the plunger  

and pump cylinder

Dry pump

Re-lube the plunger seal

Dirt on vacuum pad

Clean the vacuum pad

Dirty or uneven  

mounting surface

Clean the mounting surface or  

move to a more suitable spot

Severe  

Leakage

Dirty or uneven  

mounting surface

Clean the mounting surface or  

move to a more suitable spot

Damaged pump

Replace the vacuum pump

Nicks or cuts on vacuum pad

Replace the vacuum pad

Jammed or  

Sluggish Pump

Obstructed valve stem

Remove the obstruction; clean  

and re-lube the pump

Dry pump

Re-lube the plunger seal

Dirt in pump

Clean and re-lube the plunger  

and pump cylinder

TR

O

UB

LE

SHO

O

TI

NG

 G

UI

DE