8. Further notes
Regarding to the device functionality, GSM networks and the specialty of GSM voice calls
and SMS-s, the module requires further remarks:
a) The device can be operated with any microSIM card
b) The received unknown SMS-s, including the ones sent from the carrier (including the balance check
SMS) are forwarded to the first telephone number, if the first telephone number is specified in the
configuration.
c) If a pre-paid SIM card is used and the balance reaches zero, the device can remain operational
however it cannot send further SMS-s or initiate calls. In this case it is advised to regularly check the
balance of the card.
d) After downloading a configuration from PC via USB, the device will restart which takes 30-40
seconds, and it will be operational after registering to a GSM network.
e) All members of the
MobilGate
family can operate only with SIM cards that are not protected with
PIN codes. Please note that the SIM PIN is not equal to the module PIN number.
f)
Before device use, the PIN code has to be removed from the SIM card.
g) By using pre-paid SIM card, showing the caller ID must be enabled. This can be performed by
contacting the carrier’s customer service.
h) Call-forwarding and SMS reminders about missed calls sent by the carrier must be disabled on the
SIM card.
9. Connecting the MobilGate-128d
Specifications:
Power supply:
10–30 Vdc
Max. Current:
290 mA
Stdby (relays on):
27 mA
Stdby (relays off):
135 mA
Operat. temp:
-30..+70 C
GSM:
Dual band
Freq:
900/1800MHz
Comm:
SMS, voice
Aerial conn.:
SMA
Enclosure:
alu enclosure
Dim:
83x71x24 mm
SeaSoft
Ltd
.
-
2013 -
SeaSoft Ltd.
www.seasoft.hu - www.mobil-control.eu T: (+36) 62 406405 M: (+36) 30 2557688 F: (+36) 62 405-969