The module confirms every SMS command with a response SMS. Do not send any further SMS
commands until the confirmation SMS is received, because it might be lost and will not be executed!
The confirmation SMS shows the changed parameter and the actual status of inputs and outputs. If
the given command is wrong, the module cannot recognize it, thus an SMS with the content of
Error! will be sent back. Please configure the SMS center number first during configuration
otherwise the device will not respond for certain configuration commands and will not operate
correctly. 

Add the SMS center number first, because confirmation SMS will get back about its sending as 
well: 

i.e.

!

1234,W00,36309888000

where

 

1234

 device PIN

W00

 memory place means SMS center number

            

36309888000

  SMS center number in international format

 

(here

 hungarian T-Mobile)

i.e

.

!

1234,W01,5678

where 

5678

 device PIN

W01

 memory place is PIN code giving command

            

5678

 

new PIN code

i.e.

!

1234,W02,5566

 

where    

5566

  new device ID

            

W02

 device ID memory place

i.e.

!

1234,W11,syren 

 

where    

syren off

  

message to be sent by the device in case of output 4

              switch-off

 

W11

 memory place is content of the SMS in case of output 4

              switch-off

 SeaSoft  Ltd.    

                www.seasoft.hu  -  www.mobil-control.eu                    T: (+36) 62 406405       M: (+36) 30 2557688        F: (+36) 62 405-969  

MobilGate-128d   -   functional  memory  map  

(continued)

Memory

Function / contents

Remarks

Default

Progr.  samples

Inputs

1

st

 character

(starts SMS)

Outputs

2

nd

 character

(switched by call)

Telefon number 

3

rd

  - 13

th

  character

0

 = none

1

 = only 1st

2

 = only 2nd

3

 = both (1

st

 and 2

nd

)

28

2

1

1

st

  telefon number

---

2,1,36209876543

29

3

2

2

nd

  telefon number

---

3,2,36301234567

30

3

rd

  telefon number

---

31

4

th

  telefon number

---

32

5

th

  telefon number

---

...

...

---

...

...

---

154

127

th

 telefon number

---

155

128

th

 telefon number

---

Summary of Contents for MobilGate - 128d

Page 1: ...input and output can be labeled with a max 16 character long name The configuration of the SMS relay output commands which trigger the relays to be on or off also can be set The module has a 4 charact...

Page 2: ...icate possible error messages in the following order Red On LED Continuously The interface is operational It has to remain lit after turning it on White GSM LED Blinking GSM module operational status...

Page 3: ...and a small sized straight pole aerial or an aerial with a coax cable or similar plug can also be installed to it The power input of the GSM gate opener module is protected against reverse polarity an...

Page 4: ...are then set the Com value in Settings Port configuration menu The download software of MobilGate 128d offers a fast and simple way to configure the device Menus appearing on the screen allows the acc...

Page 5: ...can be read and it results in overwriting data on the screen with the uploaded data It is advised to check downloaded data with the yellow colored Verify Download button The Check Status function quer...

Page 6: ...for configuration MobilGate 128d functional memory map Memory Function contents Remarks Default Progr samples 00 Provider s SMS center number International format 36309888000 01 Device PIN code 4 cha...

Page 7: ...0 SMS center number in international format here hungarian T Mobile i e 1234 W01 5678 where 5678 device PIN W01 memory place is PIN code giving command 5678 new PIN code i e 1234 W02 5566 where 5566 n...

Page 8: ...rst user phone number can be queried i e 1234 R where R if there is no number after it it shows device status Response SMS in case of Default settings 1234 My house Gate motor ok Pushbutton released L...

Page 9: ...seconds and it will be operational after registering to a GSM network e All members of the MobilGate family can operate only with SIM cards that are not protected with PIN codes Please note that the...

Page 10: ...Appendix modificatons of of setting of USB serial Com port in Windows 7 step by step SeaSoft Ltd www seasoft hu www mobil control eu T 36 62 406405 M 36 30 2557688 F 36 62 405 969...

Reviews: