CHARGER OPERATION

Backup pump will start automatically when sump water
level rises far enough to trip float switch. After a delay of
about 4 seconds, alarm will sound. Silence alarm by
pushing ALARM RESET button. In normal (switch ac-
tuated) operation, alarm is locked out until about 4
seconds after float switch has dropped to OFF position;
cycle can then begin again.

Test alarm by pushing ALARM RESET button when alarm
is not sounding. Alarm will then sound as long as button is
held down. Pushing ALARM RESET button to test alarm
overrides lockout, so alarm can be tested at any time.

If alarm sounds, check operation of primary pump, which
may need service. If battery backup operation is due to a
power outage, alarm will sound, but no service is likely to
be required to primary pump.

Battery charger has capacity to run pump and charge
battery at the same time as long as power to the charger is
not interrupted. If power to charger circuit is interrupted,
the length of time that the backup pump will run depends
on the Ampere-hour capacity of the battery used.

NOTICE:  Charger will not start to charge battery unless
battery voltage is above 4 volts. If battery voltage is below
4 volts, charger will not start. In many cases, a battery that
has been exhausted (for example, after an extended power
outage) will self-regenerate far enough to allow charger to
start. This process may take several hours.

After power is restored, charger will automatically re-
charge battery fully in about 6 hours.

If battery has not reached a satisfactory voltage after 24
hours of charging, alarm will sound. In this case alarm
cannot be reset. Possible causes are:

1. Extended operation during power outage.

2. Battery depleted to less than 4 volts, extending

charging cycle to more than 24 hours.

3. Defective battery.

4. An intermittent open circuit (such as a loose

connection to battery clamp) can also cause alarm
to sound. 

After restoring power or replacing battery, alarm can be
reset.

TABLE I Performance Chart

VERTICAL PUMPING DISTANCE

5  FEET

10  FEET

15  FEET

Battery Size

27M

24M

27M

24M

27M

24M

Gallons Per Hour

1,170

1,170

768

768

120

120

Hours Available

7.0

6.0

9.0

8.0

10.5

9.0

Total Gallons Pumped

7,750

6,888

6,680

5,820

1,160

1,116

1,5 METERS

3,0 METERS

4,5 METERS

Battery Size

27M

24M

27M

24M

27M

24M

Litres Per Hour

4425

4425

2905

2905

450

450

Hours Available

7.0

6.0

9.0

8.0

10.5

9.0

Total Litres Pumped

29335

26070

25285

22030

4390

4220

GENERAL INFORMATION

The Battery-Powered Back-up Sump Pump is not a sub-
stitute for your primary sump pump. It is designed as a
backup pump to pinch-hit for your primary sump pump
during a power outage or other problem which prevents
normal operation. Do not use it to pump flammable
liquids or chemicals. If pumping salt water, flush the
pump with clear water after use.

Keep battery charger dry and protected from damage.

In an emergency (such as an extended power outage)
which depletes the system battery, your automobile
battery may be temporarily substituted. Be sure to replace
the system battery as soon as possible.

Summary of Contents for CRAFTSMAN 572.826121

Page 1: ...manual MODEL NO 572 826121 CAUTION Read all instructions carefully before starting the installation Save this Manual for future reference F642 9201 10 18 94 PRINTED IN U S A SEARS CANADA INC TORONTO...

Page 2: ...ct power to basement before walking on floor 5 Do not lift pump by electrical cord 6 Pump water only with this pump 7 Do not run pump dry To do so will damage seals and can cause leaking and property...

Page 3: ...charger will automatically re charge battery fully in about 6 hours If battery has not reached a satisfactory voltage after 24 hours of charging alarm will sound In this case alarm cannot be reset Pos...

Page 4: ...w sufficient room for float switch to swing see Figure 1 4 Make sure that installation will not interfere with primary sump pump operation as follows A Backup pump installation must not interfere with...

Page 5: ...If battery is fully charged green light CHARGED will be ON B If battery is being charged yellow light CHARG ING will be ON 4 When charger is plugged in battery is connected and unit is operating prop...

Page 6: ...ounting block off of steel band Loosen screw in block and pull switch cord out of clamp Pull new switch cord through clamp and tighten screw Make sure tether length is the same as old switch s tether...

Page 7: ...q PS17 43 Battery Case includes strap and strap brackets 7 PS17 58 Charger 8 PS22 1 Check Valve 9 Hose Clamp 1 min 2 max S S 10 PS78 3P Pipe Adapter 11 U78 846P Tee 1 1 2 x 1 1 2 x 1 1 4 PVC 12 U78 87...

Reviews: