7
12. Bolt black switch wire onto battery terminal clamp.
13. Reinstall battery clamps:
A. Black switch wire clamps to positive battery
terminal.
B. Black pump wire clamps to negative battery
terminal.
NOTICE: DO NOT reverse terminal connections.
14. Turn pump upside down; unclip and remove screen.
Do not remove screw-mounted bottom plate. Lift
switch to momentarily ”bump” pump. Check for
correct operation and rotation (pump must rotate
counter-clockwise when looking at end of shaft -
Figure 8). If not, reverse wires to battery and recheck.
15. Replace screen.
16. Plug in charger to wall outlet.
17. Fill sump with water and check switch action. Adjust
tether if necessary.
DO NOT test run pump for more than 5
seconds without water in it. Running pump dry for
extended periods could damage pump and voids
warranty.
White
Black
Negative
Black w/
Red Tracer
Positive Battery Clamp
Negative Battery Clamp
Brown
Sensor
Black
1
2
3
4,5
6A
6B
7
12
8
9
10
11
Positive
12
1412 1194
Sensor
–
–
+
+
+
REPAIR PARTS LIST
Key No.
Part No.
Part Description
1
PS217-5E
Switch Assembly #
2
PS17-41
Pump Complete***
3
U197-10
Cord Clamp Assembly
4
U17-1148
Fuse Holder
5
U17-1149
15-Amp Time-Delay Fuse (2 supplied †)
6A
**
Wire Terminal (4 Req.)
6B
**
Battery Terminal Clamps (2 Req.)
*
PS17-43
Battery Case (includes strap and strap brackets)
7
PS117-77A
Charger***
8
PS22-1
Check Valve
9
**
Hose Clamp 1" min. - 2" max. S.S.
10
PS78-3P
Pipe Adapter
11
U78-846P
Tee 1-1/2 x 1-1/2 x 1-1/4 PVC
12
U78-876P
Reducer Bushing (2 Req.)
*
F642-9411
Owner’s Manual
# When ordering, also order Key Nos. 4 (Fuse Holder) and 5 (Fuse) required for installation.
* Not illustrated.
** Standard Hardware Item; purchase locally.
*** No component parts available for pump or battery charger.
† Second fuse is supplied as spare.
To order parts, call:
Sears Product Service
1-800-366-7278
SEARS Battery Backup Sump Pump