ELECTRICAL

ELECTRICAL CONNECTIONS

Risk of electric shock. This pump is sup-

plied with a grounding conductor and grounding-type
attachment plug. To reduce the risk of electric shock,
be certain that it is connected only to a properly
grounded, grounding-type receptacle.

The Sump Pump has a 3-prong electric plug. The third prong
is used to ground the pump to prevent possible fatal shock.
The third prong should never be removed. Your electrical
outlet should be the 3-prong, polarized type with an inter-
nal ground.

A separate 15 amp individual branch electrical circuit is rec-
ommended. 

DO NOT USE AN EXTENSION CORD.

Testing For Ground

For your safety, check your outlet for ground using an
Underwriters Laboratory Listed Circuit Analyzer. (Figure
3A). A Circuit Analyzer will tell you by a pattern of lights if
the power, neutral, and ground wires are correctly con-
nected to your outlet. It can also be used to check other out-
lets in your home. A Circuit Analyzer is available in the Sears
Electrical Department.

Grounding Outlet

If your outlet is not grounded, install a copper wire (at least
14 gauge) from the outlet box, as shown in Figure 3B, to a
metal cold water pipe. Use ground clamp on pipe.

IMPORTANT:

The cold water pipe you use as a ground

must have metal continuity to electrical ground. If continu-
ity is interrupted by plastic, rubber, or other electrical insu-
lators; such as hoses, fittings, washers or gaskets (including
water meter or pump), a metal bypass must be used. Any
electrically insulated connector should be jumped (as shown
in Figure 3C), with a length of No. 4 wire clamped securely
at both ends.

Automatic Thermal Overload Protection

This pump motor has a built-in automatic thermal overload
protector. If the motor overheats, the protector will open
and cut off power to the motor before the heat damages it
internally. The overload will reset automatically and the
pump will restart after the pump cools down below the dan-
ger point.

DO NOT attempt to work on the pump or

motor if the overload seems to have tripped. The
motor may restart without warning at any time. You
could be injured and the pump damaged if it starts
when you are working on it. Remove all power from
pump before attempting to work on it.

DO NOT

attempt to repair a non-operational sump pump.

Take it to Sears for service by a qualified technician.

Generator Sizing

Below is the minimum Engine-Generator Watt rating re-
quired to power this pump motor. Any additional loads,
such as lights, must be added to the listed load and the gen-
erator sized accordingly. 

Pump

Minimum Watt

Model

HP

Rating of Generator

390.304790

1/3

3400

390.305790

1/2

4200

4

UL Listed

Analyzer

Outlet

Face Plate

Outlet

Outlet

Box

Bare Copper Wire

to Cold Water Pipe

Face

Plate Screw

No. 4

Wire

Clamp

Metal Water Pipe

Meter

Clamp

FIGURE 3A

FIGURE 3B

FIGURE 3C

Summary of Contents for CRAFTSMAN 390.304790

Page 1: ...duct Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Electrical Service Repair Parts PRINTED IN U S A PROFESSIONAL SUBMERSIBL...

Page 2: ...e pulling pump cord plug After plug is pulled let pump cool for 20 minutes before attempting to work on it Modern mo tors are designed to operate at high temperatures B Take extreme care when changing...

Page 3: ...Thread 1 1 2 x1 1 4 reducer bushing into pump discharge thread hose into bushing Run dis charge pipe to the nearest sewer outlet or other point of dis posal Use the most direct route and the fewest tu...

Page 4: ...interrupted by plastic rubber or other electrical insu lators such as hoses fittings washers or gaskets including water meter or pump a metal bypass must be used Any electrically insulated connector...

Page 5: ...arge pipe is not plugged or frozen e Be sure check valve is operating correctly Risk of electric shock Unplug pump be fore attempting to service or remove any component 1 The motor in the unit is seal...

Page 6: ...U9 370 O Ring 10 PW117 281 TSU PW117 237 TSU Cord and Plug 11 Motor Upper Volute 12 PS5 26P PS5 29P Impeller 13 PS20 21 PS20 21 Gasket 14 PS1 34P PS1 34P Lower Pump Body 15 U30 966SS U30 966SS Lower...

Page 7: ...7...

Page 8: ...isting Agreement call 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES America s...

Reviews: