ADDITIONAL INSTALLATION

MATERIALS

Sump/Utility Pump Hose Kit, SEARS Stock No. 27909, con-
taining 24’ of 1-1/4” flexible plastic pipe, a 1-1/4” plastic
adapter and a stainless steel clamp.

Check Valve, SEARS Stock No. 2789.

THE SUMP

The sump should be located at the lowest place in the base-
ment or area to be drained. Floor drains from other areas in
the basement may be tiled into the sump. Drain tile around
a house foundation can also be tiled into the sump, effec-
tively removing water and relieving pressure from this area.
A suitable sump can be a 20" or 24" sewer tile. Sump must
be at least 12” in diameter.

A sump cover is desirable to exclude refuse from the sump.
Consult local code for sump cover specifications.

SPECIFICATIONS

Power supply required ....................................115V, 60 HZ.

Horsepower (390.303301) ..............................................1/3

Horsepower (390.303491) ..............................................1/2

Motor duty .........................................................Intermittent

Liquid Temp. Range...........................32°F to 70°F(0°-21°C)

Circuit Requirement GFCI Class A..........................15 Amps

Motor full load (maximum - 390.303301) .............5.8 Amps

Motor full load (maximum - 390.303491) .............7.3 Amps

Discharge (390.303301) ......................................1-1/4" NPT

Discharge (390.303491) ......................................1-1/2" NPT

PUMP INSTALLATION

Check your local Electrical and Plumbing Codes before in-
stalling pump. You must comply with their rules.

Set the pump on the bottom of the sump, making sure that
it sits solidly and is level. Be sure there is enough space
around the pump to allow the switch free movement as the
sump water level changes. Do not install on clay, earth, or
sand.

Risk of flooding. If a flexible discharge

hose is used, pump may move around in sump when
motor starts

. If it moves far enough so that the switch hits

the side of the sump, the switch may stick and prevent
pump from starting. Make sure that pump is secured so that
it cannot “walk around” in sump.

Use 1-1/4” plastic pipe from Hose Kit No. 27909 for the dis-
charge pipe. Run the discharge pipe to the nearest sewer
outlet or other point of disposal. Use the most direct route
and the fewest turns and elbows possible. For Model
390.303491 use 1-1/2” x 1-1/4” reducer bushing (included
with pump).

Use Teflon tape to seal threads in plastic pipe. Hand tighten
only.

NOTE:

To avoid backflow into sump when pump shuts off,

install a Check Valve, SEARS Stock No. 2789, in threaded dis-
charge port of pump (390.303301) or 1-1/2”x1-1/4” reducer
bushing (390.303491). Reducer bushing is included with
Model 390.303491. Be sure arrow on check valve body
points away from the pump. This Check Valve is equipped
with an air bleed hole to prevent airlocking pump. If using
any other check valve, drill 1/8” (3.2 mm) hole in discharge
pipe just above pump body but below check valve to pre-
vent air locks.

3

Figure 1

Figure 2

Sewer Tile

Concrete

Sewer Tile

Sump Cover

Basement Floor

1/4"

12" Min.

20" to 24"

20" to 24" Diam.

Switch

Rubber Bushing
Stop (D)

Switch Arm

Rubber Bushing 
Stop (C)

Stainless
Steel Rod

Sump Cover

Rubber Bushing 
Stop (A)

Marked “TOP”

Float

Rubber Bushing
Stop (B)

Rod Guide

Check
Valve

1220 0894

Summary of Contents for CRAFTSMAN 390.303301

Page 1: ...e First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Operation Installation Service Repair Parts PRINTED IN U S A P...

Page 2: ...treme care when changing fuses To re duce the chance of fatal electrical shocks DO NOT stand in water or put your finger in the fuse socket C Ground the electrical outlet box D Use only a grounded out...

Page 3: ...ee movement as the sump water level changes Do not install on clay earth or sand Risk of flooding If a flexible discharge hose is used pump may move around in sump when motor starts If it moves far en...

Page 4: ...A set at about eight inches down from the top of the rod 3 Slide float rod up through the eye in the switch arm Add a rod stop bushing B at the top of the rod Make sure the rod guide is tightly clampe...

Page 5: ...e Engine Generator Watt rating required to power this pump motor Any additional loads such as lights must be added to the listed load and the generator sized ac cordingly Pump Minimum Watt Motor HP Ra...

Page 6: ...witch 2 U30 932ZP Screw 8 x 1 2 Hex Head 2 Required 3 RP0005257 Shaft 4 RP0005246A Column 5 PS1 25P Volute 6 SC004 116 Screw 8 18 x 3 8 Self Tap 7 PS5 21P Impeller 8 PS4 17P Base Plate 9 U30 934ZP Scr...

Page 7: ...quired 3 RP0005257 Shaft 4 S15 37SS Column 5 S1 32B Volute 6 S5 13P Impeller 7 PS4 17P Base Plate 8 U30 571BT Screw 8 32 x 1 2 Hex Head 8 Required 9 RP0005249 Rod Guide 9A U30 929ZP Screw 8x1 Phillips...

Page 8: ...enance Agreement or to inquire about an existing Agreement call 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s R...

Reviews: