-29-
CONDITION
CHECK
RESULT
CAUSE
REMEDY
No microwave
oscillation.
No continuity.
Continuity.
Abnormal
Defective high
voltage
transformer.
Replace high
voltage
transformer.
Normal
Defective PCB
assembly.
Replace PCB
assembly.
Disconnect the
wire leads from
relay 2 and
check continuity
of relay 2.
(Operate the unit)
Check high vol-
tage transformer
Output is full power
when you set lower
power level.
Abnormal.
Defective PCB
assembly.
Replace PCB
assembly.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Abnormal
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Normal
Check high vol-
tage capacitor.
Abnormal
Defective high
voltage diode.
Replace high
voltage diode.
Normal
Check high vol-
tage diode.
Abnormal
Defective
magnetron.
Replace
magnetron.
Check
magnetron.
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run.
(Display operates properly)
NOTE : • Make sure the wire leads are in the correct position.
• When Removing the wire leads from the parts, be sure to grasp the connector, not the wires.
• When removing the magnetron, be sure to install the magnetron gasket in the correct position
and in good condition.
Summary of Contents for 721.66339
Page 9: ...B MATRIX CIRCUIT FOR TOUCH KEY BOARD 8 Figure 4...
Page 32: ...31 DOOR PARTS 1004 1000 1005 1007 1006 1002 1013 1003 1001 EV...
Page 33: ...32 CONTROLLER PARTS 2000 2002 2006 W106 2004 2381 EV...
Page 34: ...33 OVEN CAVITY PARTS 3002 W107 W103 3001 3003 3008 3009 W105 3034 EV...
Page 35: ...34 LATCH BOARD PARTS W102 4002 4003 4002 4004 4000 4001 EV...
Page 37: ...36 BASE PLATE PARTS 5008 W101 W108 6000 6007 6001 EV...