4.7. 

  

ATTACH THE RAM HOSE.

  

NOTE:

 The long hose C (#57) is pre-assembled to the ram (#46).

4.7.1. 

  

Remove the dust plug from the end of long hose (#57). 

DO NOT

 discard.

4.7.2. 

  

Remove the dust plug from the connector for short/long oil hose (#71). 

DO NOT

 discard.

4.7.3. 

  

Attach the long hose (#57) to the connector for short/long oil hose (#71), located on the pump assembly (#53).

4.8. 

  

PRESSURE GAUGE

4.8.1.   

Remove the dust cap hex bolt from the pressure gauge (#50) and gauge fitting (#51). 

DO NOT

 discard.

4.8.2. 

  

Screw the pressure gauge (#50) and nylon ring (#72) into the pressure gauge fitting (#51) until tight.

 

8

  

DO NOT

 over-tighten.

4.9. 

  

ATTACH THE HANDLE

4.9.1. 

  

Remove the locking fixings hex head screw M8 x 20 (#66) and M8 flat washer (#67) from the handle (#64) and retain.

4.9.2. 

  

Insert the handle into the pump handle holder and secure with the retained fixings.

4.10. 

PLACING THE V-BLOCKS

4.10.1. 

Place the V-blocks (#32), in the required orientation, onto the bed frame (#31).

 

‰

  

WARNING!

 The V-blocks are heavy.

4.11. 

  

AIR SUPPLY

4.11.1. 

C

onnect a compressed air supply hose (fig 1) to the quick coupler (male) (#75).

4.11.2. 

The recommended working air supply is a pressure is between 108-123psi.

5.  INSTALLATION

   

DANGER!

 Models are purpose designed to withstand greater loads than the hydraulic units can develop. For safety reasons, always  

 

ensure the workpiece and press tools are secured on the table and will not flex or suddenly “give way” causing danger to    

 

 

operator or the component.

5.1. 

  

SECURE PRESS TO THE FLOOR

 

8

  

DO NOT

 attempt to move assembled press manually. When moving the press follow the instructions as detailed in Section 1.

5.1.1. 

  

Move the press to the mounting location, and spot mark through fixing holes in base section (#1) onto the floor.

5.1.2. 

  

Check for any hidden wiring or cables, if needed change the location for the holes.

5.1.3. 

  

Temporarily move the press to the side.

5.1.4. 

  

Use a masonry drill bit to drill the four holes about 3” to 4” (75 to 100mm) deep into the concrete or wood, as necessary.

5.1.5. 

  

Clean out the drilled holes.

5.1.6. 

  

Position the press and align the holes in the base section with the holes in the floor.

5.1.7. 

  

Use four concrete anchor bolts or lag bolts for wooden floors, (not included), to secure to the floor.

 

‰

  

WARNING!

 To prevent serious injury 

DO NOT

 use damaged equipment. If abnormal noise or vibration occurs have the problem    

 corrected.

 

‰

  

WARNING!

 Ensure the mounting surface is capable of withstanding the weight of the press and workpieces.

5.2. 

  

BEFORE FIRST USE

5.2.1.   

Before operating the press, purge the hydraulic system in order to eliminate any air that may have built up during transit. Open    

 

the release valve and pump the handle several times and close the release valve. Should the system malfunction at any time,  

 

 

repeating this process may resolve the problem.

 

  

DANGER

Models are purpose designed to withstand greater loads than the hydraulic units can develop. For safety reasons,  

 

  always ensure the workpiece and press tools are secured on the table and will not flex or suddenly “give way” causing danger to   

 

operator or the component. Also ensure you have read and understood section 1 Safety Instructions.

6.  OPERATION

6.1.    

SETTING THE BED FRAME HEIGHT

6.1.1. 

  

Turn the hand winch handle (#12) until the cables just takes the weight of the bed frame (#31).

6.1.2. 

  

Remove the retaining clips (#19) from the back of the bed frame pins (#18) and withdraw the pins, store in a secure location.

6.1.3. 

  

Use the hand winch handle (#12) to raise or lower the bed frame (#31) to the desired height.

6.1.4. 

  

Re-insert the bed frame pins (#18) and the retaining clips (#19).

6.1.5. 

  

Slacken off the hand winch (#12) so that the bed frame pins (#18) are taking the full weight of the bed frame (#31).

6.2. 

  

Check that the release valve on the hydraulic unit is fully closed, ready for operating.

6.3. 

  

Position the V-block (#32) or press tools to be used onto the table and align beneath the ram. Place workpiece onto the table or  

 

 

V-blocks and align beneath the ram as required.

  

NOTE:

 Care must be taken to ensure a V-block does not fall from the press table. If necessary hold the configuration in position with  

 

  clamps (not supplied).

 

‰

  

WARNING!

 

DO NOT

 apply off centre loads.

6.4. 

  

Connect the air supply to the foot pedal (#61) quick coupler (male) (#75).

6.5. 

  

Use the handle or the foot pedal to lower the ram to the workpiece.

 

‰

  

WARNING!

 Monitor the pressure gauge during operation to ensure that the rated capacity of the press is not exceeded.

6.6. 

  

When the operation is complete turn the release valve anti-clockwise to release the pressure. The piston and the ram head will  

 

 

retract automatically.

6.7. 

  

Disconnect the air supply.

  

NOTE:

 Always keep the piston retracted after use to avoid corrosion.

Original Language Version

© Jack Sealey Limited

   fig.1

YK759FAH.V2  Issue 1 01/08/22

Summary of Contents for YK759FAH.V2

Page 1: ...ve 8 DO NOT exceed the rated capacity of the press 8 DO NOT apply off centre loads 8 DO NOT allow the workpiece or the press plates to fall from the work table 8 DO NOT get the press wet or use in damp or wet locations or areas where there is condensation 8 DO NOT operate the press when you are tired or under the influence of alcohol drugs or intoxicating medication 8 DO NOT climb upon the press 8...

Page 2: ...M12 4 loosely 4 2 5 Follow section 4 2 4 to attach the other support 1 4 2 6 Repeat sections 4 2 1 to 4 2 5 to attach the other base assembly 4 2 7 On a flat level floor level the frame using a good quality spirit level Fully tighten all fixings 4 2 8 Remove the load slings and store them in a safe and secure location WARNING Take care and seek assistance from another person when lowering and leve...

Page 3: ...ent If abnormal noise or vibration occurs have the problem corrected WARNING Ensure the mounting surface is capable of withstanding the weight of the press and workpieces 5 2 BEFORE FIRST USE 5 2 1 Before operating the press purge the hydraulic system in order to eliminate any air that may have built up during transit Open the release valve and pump the handle several times and close the release v...

Page 4: ...sposal draw off the oil into an approved container and dispose of the product and the oil according to local regulations Original Language Version Jack Sealey Limited Sealey Group Kempson Way Suffolk Business Park Bury St Edmunds Suffolk IP32 7AR 01284 757500 01284 703534 sales sealey co uk www sealey co uk ENVIRONMENT PROTECTION Recycle unwanted materials instead of disposing of them as waste All...

Reviews: