background image

3. 

SPECIFICATION

4.  OPERATION

4.1. 

  

Check the equipment rating and operation against the transformer rating. The transformer will supply intermittently used equipment  

 

up to the plate rating but if the equipment is used continuously then the transformer rating should be reduced see section 3.

4.2. 

  

It is normal for the transformer to get warm during use, particularly if being used continuously, so care should be taken to place  

 

 

only on surfaces that will not be damaged by the heat.

4.3. 

  

A temperature sensitive cut-out switch is fitted to prevent overheating. If this switch trips, determine and rectify the cause of  

 

 

overheating and allow time for the transformer to cool before pressing the reset button. (Located on one of the sides adjacent to the   

 

output sockets). 

4.4. 

  

The transformer should be plugged directly into a 230V mains socket and should not be supplied via an extension lead. Any  

 

 

necessary extension lead should be between the transformer and the tool/equipment. Extension leads are available from your  

 

 

Sealey stockist. 

 IMPORTANT: 

The transformer is not double insulated and the safety screen between primary (230V) and secondary (110V) windings 

 

is connected to the earth core of the power cable. For these reasons it is extremely important to confirm that the power socket to be

 

used is reliably and permanently earthed.

4.5. 

  

Tool transformers can draw a very high initial current when switched on. If fuse failure occurs at switch-on check that the fuse is a    

 

13 amp, anti-surge type. Any circuit breaker protecting the supply socket should have a suitable tripping characteristic. 

 

8

   DO  NOT

 exceed 1.5kV when flash testing.

4.6. 

  

A plug suitable for the transformer output is available from your Sealey stockist.  

 

© Jack Sealey Limited

MODEL NO:

WST1500

WST3000

WST5000

WST10000

Power tool rating (VA)

1500

3000

5000

10000

Continuous rating (VA)

900

1650

2800

7000

Output Sockets

2 x 16A

2 x 16A

2 x 16A

1 x 32A

2 x 32A/110V sockets 4 x 

16A/110V

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

 01284 757500 

 01284 703534 

 [email protected] 

 www.sealey.co.uk

ENVIRONMENT PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 

a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 

unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 
according to local regulations.

Note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice.

Important

: No Liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.

WEEE REGULATIONS

Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment 
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid 

waste authority for recycling information.

Original Language Version

WST1500, 3000, 5000, 10000  Issue 1   04/04/22

Reviews: