background image

2.  INTRODUCTION & SPECIFICATIONS

3.  OPERATING INSTRUCTIONS

4. MAINTENANCE

 

WARNING! Ensure you read, understand and apply safety instructions. 

IMPORTANT . As a guide limit the maximum continuous running time for the pump to six hours, followed by three hours downtime.
3.1.

  

fit appropriate discharge pipe to pump outlet and secure with clip. Ensure the diameter of the discharge pipe is same as, or greater    

 

than, the outlet diameter. A smaller pipe will adversely effect the pump flow rate. 

3.2.

 

Position pump in the water, and place the outlet pipe securely in the discharge receptacle or  area. We  recommend the pump is  

 

 

submerged with its discharge outlet facing up to release any trapped air.

3.3.

 

Plug the pump into the electrical mains supply and switch on. The pump will automatically turn on as the level of water rises (fig.3A).   

 

As water level lowers, the float will automatically switch the pump off as it reaches the minimum height (fig.3B). The float may be  

 

 

adjusted by shortening or lengthening the cable using the notch in the handle. The pump will switch on if the water level is up to or    

 

above the maximum length of the float cable. To function correctly the float must move freely. Ensure the float can do so and  

 

 

that the cable is not restricted. check that the pump and discharge are working correctly.

3.4.

 

The water into which the pump is placed will act as the motor cooling agent. for this reason the pump must remain submerged at all   

 

times. Should the pump have to be used in shallow water 

DO NOT

 operate for more than 10 minutes. failure to follow this rule will    

 

damage the unit and will invalidate your warranty.

 NOTE:

 See fig.4 to determine minimum clearance required if using the pump in a restricted area, such as a well or a trough.

 

WARNING! With the exceptions listed below in "TROUBLESHOOTING", all pump, float, electrical cable service/maintenance and 

repair must only be undertaken by an authorised service agent. Failure to observe this rule may be dangerous and will invalidate 
your warranty.

 

WARNING! Ensure the pump is disconnected from the mains power supply before attempting any service or maintenance.

4.1.

 

Keep all parts of the pump clean. rinse, drain and allow to dry before storing pump. 

4.2.

 

regularly check the water inlet on the base of the pump to ensure there are no blockages. To access the impeller, carefully undo the   

 

base screws and remove base. clean impeller and replace base ensuring that the “o” ring is correctly located. 

 

DO NOT

 dismantle any other part of the unit.

fig.3

fig.4

Manufactured from corrosion resistant materials with stainless steel body and motor case. Massive maximum head of 40mtr makes this unit 
ideal for wells. fitted with automatic cut-out. Minimum water depth of 32mm. Designed for clean water although these pumps will accept small 
particles up to 0.5mm. Suitable for the effective drainage of cellars, sinks, cisterns, baths and the general transfer of water. 

 

 a.

 Motor operates but 

     there is no suction.

 b.

 reduced water 

     volume for level 
     of water

 c.

 The pump will not 

     start or suddenly 
     stops during 
     operation. 

1.

 no electrical power.

2.

 float not working

3.

 Impeller is jammed.

1. 

check cable, plug and fuse.

2.

 contact authorised service agent.

3.

 clean the pump.

1. 

Discharge pipe bent, or pinched.

2.

 Discharge pipe too narrow.

3.

 Pump partially blocked.

1.

 Straighten pipe

2.

 use wider diameter pipe.

3.

 clean pump.

1. 

Water level below minimum suction depth.

2.

  Air bubbles in pump accumulated during submersion, 

    or float is incorrectly positioned so pump does not stop 
    at minimum level and sucks in air.

3. 

clogged intake filter or discharge pipe

1.

 Stop the pump.

2.

 release air by inclining the pump and 

    re-immersing it in water.

3.

 remove dirt, and clean the unit.

TROUBLESHOOTING

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: 

no liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION:

 for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. Edmunds, Suffolk,
IP32 7Ar

www.sealey.co.uk

Web

email

Original Language Version

 WPS92A    Issue: 1 - 14/11/13

© Jack Sealey Limited

500 500

600

1" BSP
female
port

float 
switch

Moulded 3 pin plug

with 10mtr flying lead

Moulded
carry/hoist
handle

Model  no:................................ WPS92A
cutout:.....................................Automatic
outlet:......................................1" BSP female
Maximum output:.................... 92ltr (20gal)/minute
Minimum Water Depth:............32mm
Maximum Water Depth:...........7mtr.
Maximum Particle Size:...........0.5mm
Maximum Head:......................40mtr.
Motor Power:...........................1000W
Supply:.................................... 230V

fig.2

 

  

Environmental Protection.

  

recycle unwanted materials instead of disposing of them as  

   

waste. All tools, accessories and packaging should be sorted,  

   

taken to a recycle centre and disposed of in a manner which  

   

is compatible with the environment.

  

WEEE Regulations.

  

Dispose of this product at the end of its working life in compliance   

   

with the Eu Directive on Waste Electrical and Electronic Equipment.  

   

When the product is no longer required, it must be disposed of in an  

   

environmentally protective way. contact your local solid waste  

 

   

authority for recycling information.