INSTRUCTIONS FOR
SUBMERSIBLE STAINLESS WATER PUMP
AUTOMATIC 225LTR/MIN
MODEL NO:
WPS225P
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
1.1.
ELECTRICAL SAFETY
WARNING!
It is the user’s responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and
all electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical
products. You may obtain an RCD by contacting your local Sealey dealer.
If the pump is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable Appliance
Test) tested.
Electrical safety information, it is important that the following information is read and understood.
1.2.
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
1.3.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
1.4.
Important
: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the
correct fuse - see fuse rating in these instructions.
8
DO NOT
pull or carry the appliance by the power cable.
8
DO NOT
pull the plug from the socket by the cable.
8
DO NOT
use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or
replaced immediately by a qualified electrician.
1.5.
This product is fitted with a BS1363/A 13 Amp 3 pin plug.
If the cable or plug is damaged during use, switch the electricity supply and remove from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
1.6.
GENERAL SAFETY
WARNING!
Pump must be used in accordance with Health & Safety, government, local authority, and water authority rules and
regulations.
9
Familiarise yourself with application and limitations, as well as the specific potential hazards peculiar to the pump.
WARNING!
Disconnect the
pump from the mains power before changing accessories, servicing or performing any maintenance.
9
Maintain the
pump in good condition (use an authorised service agent). Keep the pump clean.
9
Replace or repair damaged parts.
Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9
If the bottom of the water container is covered with sludge, sand, gravel or mud etc, suspend the pump or place it on a raised base to
operate above the solid matter. Sand and such substances will reduce working life of pump, and invalidate your warranty.
9
In swimming pools, fish ponds, etc, ensure location is clear of people and animals, including removal of fish from pond.
Note:
this pump is not designed for continuous use in a fish pond or similar water feature or display.
8
DO NOT
operate the pump if any parts are damaged or missing as this may cause failure and/or possible personal injury.
8
DO NOT
use the pump for any purpose other than for that which it is designed.
8
DO NOT
use to pump, chemicals, fuels, salt water, explosive, corrosive, inflammable or health-hazardous substances, dangerous liquids
or faecal matter.
8
DO NOT
insert hands into the mouth of the pump as this could lead to injury.
8
DO NOT
use to pump septic tanks or settling pits.
DO NOT
pump any liquids other than water.
8
DO NOT
use with liquids containing abrasive materials (e.g. sand) or containing mixtures of dirt, sand, mud or clay.
8
DO NOT
operate the pump out of water. The pump pick up area must be completely submerged during operation.
8
DO NOT
exceed the maximum submersible depth - see specifications.
8
DO NOT
operate the pump during freezing temperatures.
DO NOT
leave the pump in water that may freeze.
8
DO NOT
pump liquids over 35°C in temperature.
8
DO NOT
use for pumping sea water or inflammable, corrosive, explosive or dangerous liquids.
8
DO NOT
carry the pump by its electrical cable, or outlet pipe. Use the handle only.
8
DO NOT
touch the mains plug with wet hands.
8
DO NOT
kink, crush, drag or drive over the mains cable and protect it from sharp edges oil and heat.
WPS225P| Issue 1 11/12/15
Original Language Version
© Jack Sealey Limited
Refer to
Instruction
Manual
Recommended fuse rating
13 Amp