2.  INTRODUCTION & SPECIFICATIONS

3. OPERATION

Manufactured from corrosion resistant materials with stainless steel motor case and Noryl base cover. Fitted with automatic cut-out. Puddle 

pump with minimum water depth of just 2mm makes this ideal for flood recovery. Designed for clean water although these pumps will accept 

small particles up to 5mm. Suitable for the effective drainage of cellars, sinks, cisterns, baths and the general transfer of water.

SPECIFICATION:

 

Model No:

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

WPL117A

 

Cut-out:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Automatic

 

Outlet O/D:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32mm(1"BSP)/24mm

 

Maximum Output:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117ltr(26gal)/min

 

Maximum Head:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7mtr

 

Maximum Water Depth: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5mtr

 

Minimum Water Depth:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2mm

 

Maximum Particle Size: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5mm

 

Motor Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .400W

 Supply:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V

 

WARNING! Ensure you read, understand and apply safety instructions.

3.1.

   Fit an appropriate discharge pipe to pump outlet and secure with a clip. Ensure the diameter of the discharge pipe is the same as or   

 

greater than the outlet diameter, as a smaller pipe will adversely effect the pump flow rate. 

3.2.

 

Position the pump in the water accordingly, and place the outlet pipe securely in the discharge receptacle or area. It is recommended  

 

that the pump is sunk with its discharge outlet facing up, to release any trapped air.

3.3.

 

Connect the pump to the electrical mains supply and switch it on.

3.4.

 

USING AS A CONVENTIONAL SUBMERSIBLE PUMP: 

The pump will turn on automatically as the level of water rises (fig.1.A). As the  

 

water level lowers, the float will switch the pump off automatically as it reaches the minimum height (fig.1.B). The float may be adjusted  

 

by shortening or lengthening the cable (fig.2). The pump will switch on if the water level is up to or above the maximum length of the   

 

float cable. To function correctly the float must move freely. Ensure the float can do so and that the cable is not restricted. Check that   

 

the pump and discharge are working correctly.

 