background image

INSTRUCTIONS FOR

HIGH FLOW SUBMERSIBLE STAINLESS DIRTY 

WATER PUMP AUTOMATIC 417LTR/MIN 230V

MODEL NO: 

WPD415

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY

1.1.   

 

ELECTRICAL SAFETY

 

‰

  

WARNING!

 It is the user’s responsibility to check the following:

 

Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and    

 

all electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical  

 

products. You may obtain an RCD by contacting your local Sealey dealer. 

 

If the pump is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable Appliance  

 

Test) tested.

 

Electrical safety information, it is important that the following information is read and understood.

1.2.    

Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

1.3.    

Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

1.4. 

  

Important

: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the    

 

correct fuse - see fuse rating in these instructions.

 

8

   DO  NOT

 pull or carry the appliance by the power cable.

 

8

  

DO NOT

 pull the plug from the socket by the cable. 

 

8

   DO  NOT

 use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or  

  replaced immediately by a qualified electrician.

1.5. 

  

This product is fitted with a BS1363/A 13 Amp 3 pin plug. 

 

If the cable or plug is damaged during use, switch the electricity supply and remove from use. 

 

Ensure that repairs are carried out by a qualified electrician.

 

Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

 

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b) Connect the BROWN live wire to the live terminal ‘L’.

 

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

 

Sealey recommend that repairs are carried out by a qualified electrician. 

1.6. 

  

GENERAL SAFETY

 

‰

   WARNING! 

Pump must be used in accordance with Health & Safety, government, local authority, and water authority rules and    

 regulations.

 

9

   Familiarise yourself with application and limitations, as well as the specific potential hazards peculiar to the pump.

 

‰

   WARNING! 

Disconnect the

 

pump from the mains power before changing accessories, servicing or performing any maintenance.

 

9

   Maintain  the

 

pump in good condition (use an authorised service agent). Keep the pump clean.

 

9

   Replace or repair damaged parts. 

Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

 

9

   If the bottom of the water container is covered with sludge, sand, gravel or mud etc, suspend the pump or place it on a raised base to 

   

  operate above the solid matter. Sand and such substances will reduce working life of pump, and invalidate your warranty.

 

9

 

  In swimming pools, fish ponds, etc, ensure location is clear of people and animals, including removal of fish from pond. 

     Note:

 this pump is not designed for continuous use in a fish pond or similar water feature or display.

 

8

 

 

DO NOT

 operate the pump if any parts are damaged or missing as this may cause failure and/or possible personal injury.

 

8

 

 

DO NOT

 use the pump for any purpose other than for that which it is designed.

 

8

  

DO NOT

 use to pump, chemicals, fuels, salt water, explosive, corrosive, inflammable or health-hazardous substances, dangerous liquids  

  or faecal matter.

 

8

 

 

DO NOT

 insert hands into the mouth of the pump as this could lead to injury.

 

8

 

  DO NOT

 use to pump septic tanks or settling pits.

 DO NOT

 pump any liquids other than water.

 

8

  

DO NOT

 use with liquids containing abrasive materials (e.g. sand) or containing mixtures of dirt, sand, mud or clay.

 

8

 

 

DO NOT

 operate the pump out of water. The pump pick up area must be completely submerged during operation.

 

8

 

 

DO NOT

 exceed the maximum submersible depth - see specifications.

 

8

 

 

DO NOT

 operate the pump during freezing temperatures. 

DO NOT

 leave the pump in water that may freeze.

 

8

 

  DO NOT

 pump liquids over 35°C in temperature.

 

 

8

 

 

DO NOT

 use for pumping sea water or inflammable, corrosive, explosive or dangerous liquids. 

 

8

 

 

DO NOT

 carry the pump by its electrical cable, or outlet pipe. Use the handle only. 

 

8

  

DO NOT 

touch the mains plug with wet hands.

 

8

  

DO NOT

 kink, crush, drag or drive over the mains cable and protect it from sharp edges oil and heat.

WPD415| Issue 1 15/12/15

Original Language Version

© Jack Sealey Limited

Refer to 

Instruction 

Manual

Recommended fuse rating

13 Amp

Reviews: