pNEUMATIC VACUUM BRAKE BLEEDER
mODEL NO:
Vs021.V3
Thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. sAFETY
9
Keep this product in good working order and condition, take immediate action to repair or replace damaged parts.
9
Use approved parts only. Unapproved parts may be dangerous and will invalidate the warranty.
9
Keep children and unauthorised persons away from the work area.
9
Keep work area clean and tidy and free from unrelated materials.
9
Ensure the work area has adequate lighting.
8
DO NOT
use the kit to perform a task for which it is not designed.
8
DO NOT
allow untrained persons to use the kit.
8
DO NOT
use whilst under the influence of drugs, alcohol or intoxicating medication.
9
After use, clean equipment and store in a cool, dry, childproof area.
9
Dispose of waste liquids in accordance with local authority regulations.
WARNING!
DO NOT
pollute the environment by allowing uncontrolled discharge of fluids.
9
Always read and comply with the warnings on the brake fluid container.
9
Wear eye and skin protection. If brake fluid enters eyes rinse with plenty of water and seek medical advice. If swallowed seek
medical advice immediately.
WARNING!
Brake fluid is flammable - keep away from sources of ignition, including hot surfaces e.g. exhaust manifold.
WARNING!
Brake fluid will damage paintwork. Any spillage should be flushed with water immediately.
2. INTRODUCTION
S
imple, one man operation using standard workshop air supply (90-120psi). Quick, clean and efficient. Does not require specialised brake
reservoir caps. Draws fluid from the bleed nipple enabling either bleeding or full replacement of fluid in system. Includes reservoir top-up kit
guidance notes. Utilises same vacuum unit as Model no. VS020. Includes reservoir top-up kit.
3. spECIFICATION
model no ................................................................
VS021.V3
Inlet size ....................................................................
1/4”BSP
m
aximum air pressure
.................................................
120psi
Air consumption .......................................................
180lt/min
4. CONTENTs
1. Filter
2. Lid assembly
3. Hose
4. Trigger
5. Container
6. Reservoir lid
7. Reservoir
8. Adaptor A
9. Adaptor B
10. Adaptor C
11. Adaptor D
Refer to
instruction
manual
Wear eye
protection
Wear protective
gloves
Original Language Version
© Jack Sealey Limited
V
S021.V3 | Issue:3 (H,F) 22/08/19