1.  safetY instruCtiOns

IMPORTANT:

 

please read tHese instruCtiOns CarefullY. nOte tHe safe OperatiOnal reQuirements, WarninGs & CautiOns. 

use  tHe  prOduCt  COrreCtlY  and  WitH  Care  fOr  tHe  purpOse  fOr  WHiCH  it  is  intended.  failure  tO  dO  sO  maY  Cause 

damaGe and/Or  persOnal  inJurY, and  Will  inValidate  tHe  WarrantY.  please  Keep  instruCtiOns  safe  fOr  future  use.

1.1. 

eleCtriCal safetY

  

WarninG!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other 

connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A 

residual current circuit Breaker (rccB) should be incorporated in the main distribution board. We also recommend that a residual current 

device (rcd) is used. It is particularly important to use an rcd with portable products that are plugged into a supply which is not protected 

by an rccB. If in any doubt consult a qualified electrician. You may obtain a residual current device by contacting your sealey dealer. 

You must

 also read and understand the following instructions concerning electrical safety.

1.1.1.  the 

electricity at Work act 1989 

requires all portable electrical appliances, if used on business premises, to be tested by a qualified  

 

electrician, using a Portable Appliance tester (PAt), at least once a year.

1.1.2.  the 

Health & safety at Work act 1974 

makes owners of electrical appliances responsible for the safe condition of those appliances  

 

and the safety of the appliance operators. 

if in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. see 1.1.1. and 1.1.2.    

 

and use a Portable Appliance tester.

1.1.4.  ensure that cables are always protected against short circuit and overload.

1.1.5.  regularly inspect power supply cables and plugs for wear or damage and check all  

 

connections to ensure that none is loose.

1.1.6. 

important:

 ensure that the voltage marked on the appliance matches the power supply 

 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7. 

dO nOt

 pull or carry the appliance by the power cable.

1.1.8. 

dO nOt 

pull the plug from the socket by the cable.

1.1.9. 

dO nOt

 use worn or damaged cables, plugs or connectors. Immediately have any faulty 

 

item repaired or replaced by a qualified electrician. When an AstA/Bs approved uK 

 

3 pin plug is damaged, cut the cable just above the plug and 

dispose of the plug safely. 

 

fit a new plug according to the following instructions (uK only).

 

a)  Connect the Green/YellOW earth wire to the earth terminal ‘e’.

 

b)  Connect the BrOWn live wire to the live terminal ‘l’.

 

c)  Connect the Blue neutral wire to the neutral terminal ‘n’.

 

d)  after wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer  

 

 

   insulation extends beyond the cable restraint and that the restraint is tight.

 

double insulated products, which are always marked with this symbol      , are fitted with live (brown) and neutral (blue) wires only.    

 

to rewire, connect the wires as indicated above - 

dO nOt

 connect either wire to the earth terminal.

1.1.10.  If an extension reel is used it should be fully unwound before connection. A reel with an rcd fitted is preferred since any appliance    

 

plugged into it will be protected. the cable core section is important and should be at least 1.5mm², but to be absolutely sure that the  

 

capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use   

 

of 2.5mm² section cable.

1.1.11 

electrical resistance of delivery hose in relation to static electricity.

 Hoses with insuffient resistance can cause explosions. In    

 

order to deliver fuel without risk the delivery hose should have a resistance of > 10

11

ohm. If it is necessary to replace the hose use    

 

only the original recommended spare part.

fuse ratinG

 

13 amp

Blue 

Neutral 

Wire

Yellow & Green 

Earth Wire 

Cable 

Restraint

Brown

Live 

Wire

1.2. 

General safetY

 

WarninG!

 ensure health & safety, government and local authority regulations relating to the transfer of diesel are adhered to when using  

  this equipment. familiarise yourself with the pumps applications and limitations, and specific potential hazards peculiar to the pump.

 

danGer: the electric pump is not protected against explosion and should therefore not be operated in areas where there  

 

  is a risk of explosion and should only be used to deliver diesel, heating oil and other thin oils. 

 

WarninG!

 

disconnect the pump from the mains power before demounting, servicing or performing any    

  maintenance.

 

use the pump only to deliver diesel and heating oil at a temperature between -10°C and +35°C. 

  the temperature limits must not be exceeded.

 

danGer: dO nOt use for pumping petrol.

 

the pump should only be mounted vertically.

 

maintain pump in good condition (use authorised service agent).

 

drain pump and pipes before dismantling.

 

maintain correct balance and footing when installing and using the pump. ensure the floor is not slippery and  

  wear non slip shoes.

 

ensure the transfer area is free of clutter and has adequate lighting.

 

ensure that the voltage of the pump matches the voltage of the supply.

  Keep children and unauthorised persons away from the working area.

  replace/repair damaged parts. use genuine parts. unauthorised parts are dangerous and will invalidate warranty.

 

do not smoke whilst handling the pump and fuel.

 

do not operate the pump in areas where there may be flying sparks.

 

do not use the pump without the delivery nozzle attached.

 

do not start or stop the pump by switching on or off at the mains power supply.

 

do not operate the unit with wet hands.

 

We recommend use of diesel resistant gloves and goggles.

 

do not run the pump dry. If this occurs the pump will be damaged and your warranty will be invalidated.

 

impOrtant:

 It is the installer’s responsibility to ensure that all supply pipes, fixtures and fittings are adequate for the safe flow of diesel fuel.

Original Language Version

tP97, tP9724, tP97230    Issue: 3 - 22/03/10

Summary of Contents for TP97

Page 1: ...UE neutral wire to the neutral terminal N d After wiring check that there are no bare wires that all wires have been correctly connected that the cable outer insulation extends beyond the cable restraint and that the restraint is tight Double insulated products which are always marked with this symbol are fitted with live brown and neutral blue wires only To rewire connect the wires as indicated a...

Page 2: ... joint with hose clamp 7 3 2 2 Cut the suction hose to length bearing in mind that the pump may be mounted to more than one container and that the filter must be always be under the surface of the fuel even when the fuel level is low 3 2 3 Slide the second hose clamp 5 over the end of the suction hose Push the suction hose over the suction union on the pump 4 Slide the hose clamp up onto the joint...

Page 3: ...er or for storage observe the following procedure 4 4 2 Take suitable precautions to clear up minor spills of fuel that may occur when demounting the pump 4 4 3 Switch the pump off and disconnect it from the battery or unplug it from the mains power supply 4 4 4 Before the pump can be unscrewed from the fuel container the delivery hose must be disconnected 4 4 5 To empty the fuel remaining in the ...

Page 4: ...25 and leave your full name and address including postcode 01284 757500 01284 703534 sales sealey co uk Sole UK Distributor Sealey Group Kempson Way Suffolk Business Park Bury St Edmunds Suffolk IP32 7AR www sealey co uk Web email Original Language Version ITEM PART No DESCRIPTION 1A 179 23710 930 PUMP 12V WITH CABLE AND CASING 1B 179 23720 930 PUMP 24V WITH CABLE AND CASING 1C 179 23731 930 PUMP ...

Reviews: