8
DO NOT
allow children to operate the product without adult supervision. Wash and clean out the outlet, plug, and plug blades
regularly.
9
If the power supply adapter falls into the water, pull the plug out and
DO NOT
reuse it.
9
Make sure to hold on the plug and pull it out from the outlet. (
DO NOT
pull on the cable).
8
DO NOT
get power cable damaged, bent, pulled, twisted, or bound.
8
DO NOT
get the plug and outlet wet.
9
When you hand it over to another person, be sure to give them the instructions too.
8
DO NOT
use deteriorated or contaminated liquids and fuels.
8
DO NOT
use this pump for hot liquids above 40°C (104°F ).
9
Use it in a well-ventilated area since the power supply adaptor becomes a little hot.
8
DO NOT
run the pump ‘dry’ or let the pump idle without transferring.
8
DO NOT
run the pump for longer than 15 minutes.
9
Make sure to turn on the power after using the pump.
9
Make sure to remove any left-over liquid in the discharge hose after each use.
9
After using the pump,
DO NOT
keep it on its side or upside down.
8
DO NOT
alter or disassemble the pump.
8
DO NOT
shock the pump and power supply adapter. Also
DO NOT
strain the power cable.
9
When cleaning up the pump,
DO NOT
use thinner, benzene, organic solvent, or glass cleaners.
2. INTRODUCTION
E
lectric drum mounted pump designed for pumping diesel, AdBlue®, antifreeze, detergents, water and light oils up to a viscosity of 100cst.
Fitted with built-in fuse for protection, with a silenced motor keeping noise to a minimum. Telescopic suction tube features a stainless steel
filter at the base of the tube, preventing foreign matter from entering the motor. Pump housing features a convenient holder for storing the
dispensing nozzle. Includes 230V mains adaptor and 12V battery clips allowing user to operate unit with whichever supply is available.
Supplied with a 2”BSP adaptor, 2m hose and manual dispensing nozzle with spout.
3. SPECIFICATION
Model No:............................................................ TP6818.V2
Current: ...........................................................................
3.0A
Duty Cycle: ..................................................
15min, 30min off
Flow Rate: .................................................................
16L/min
Fuse: ..................................................................................5A
Power: ..........................................................................
16.8W
4. OPERATION
4.1.
Adjust the length of the suction pipe to fit the drum (fig.2).
4.2.
Insert the suction pipe into the drum (fig.2).
4.3.
Tighten the drum bung adapter (fig.3).
4.4.
Connect power supply to the pump (fig.4).
4.5.
Pull out the nozzle from the nozzle holder (fig.5).
4.6.
Place the nozzle into the receiving container (fig.6).
4.7.
Switch on the pump by moving the switch up (fig.7).
4.8.
Pull the nozzle lever and start supplying the liquid (fig.8).
4.9.
Release the leaver when the liquid supply is complete (fig.9).
4.10.
S
witch off the pump by moving the switch down (fig.10).
4.11.
Lift the nozzle up and pull the lever (fig.11).
4.12.
D
rain the liquid in the hose back into the drum (fig.12).
4.13.
I
nsert nozzle into the nozzle holder for storage (fig.13).
fig.1
Original Language Version
© Jack Sealey Limited
T
P6818.V2 Issue 1 07/09/20