3. SPECIFICATION

Function

Range

Resolution 

Accuracy

DC Voltage

(V DC)

200mV

0.1mV

±(0.5% r 2 digits)

2000mV

1mV

20V

0.01V

200V

0.1V

±(0.8% r 2 digits)

600V

1V

AC Voltage

(V AC)

200V

0.1V

±(1.2% r 10 digits

(50/60Hz)

600V

1V

DC Current

(A DC)

2000µA

1µA

±(1.0% r 2 digits)

20mA

10µA

200mA

100µA

±(1.2% r 2 digits)

10A

10mA

±(2.0% r 2 digits)

Resistance

200Ω

0.1Ω

±(0.8% r 2 digits)

2000Ω

1Ω

20kΩ

0.01kΩ

200kΩ

0.1kΩ

2000kΩ

1kΩ

±(1.0% r 2 digits)

Battery Test

9V

10mV

±(1.0% r 2 digits)

1.5V

10mV

NOTE! Accuracy specifications consist of two elements:

1. 

 (% reading) – This is the accuracy of the measurement circuit.

2. 

 (+ digits) – This is the accuracy of the analog to digital converter.

 

NOTE! Accuracy is stated at 65°F to 83°F (18°C to 28°C) and less than 75% RH.

Diode Test: ...................................Test current of 1mA maximum, open circuit voltage 2.8V DC typical.

Continuity Check: ........................

Audible signal will sound if the resistance is less than approximately 30Ω.

Battery Test Current: ....................9V (6mA); 1.5V (100mA).

Input Impedance: .........................

>1MΩ.

ACV Bandwidth: ..........................45Hz to 450Hz.

DCA Voltage Drop: ......................200mV.

Display: ........................................3 ½ digit, 2000 count LCD, 1.1” digits.

Overrange Indication: ..................“I” is displayed.

Polarity:........................................Automatic (no indication for positive polarity); Minus (-) sign for negative polarity.

Measurement Rate: .....................2 times per second, nominal.

Low Battery Indication: ................“BAT” is displayed if battery voltage drops below operating voltage.

Battery: ........................................One 9 volt (PP9) battery.

Fuses:  .........................................mA, µA ranges; 0.2A / 250V fast blow. 

A Range: ......................................10A/250V fast blow.

Operating Temperature: ...............32°F to 122°F (0°C to 50°C).

Storage Temperature: ..................-4°F to 140°F (-20°C to 60°C).

Relative Humidity:........................<70% operating, <80% storage.

Operating Altitude: .......................7000ft. (2000) meters maximum.

Weight:  .......................................255g.

Size:   ..........................................150mm x 70mm x 48mm.

Safety: For indoor use and in accordance with Overvoltage Category II, Pollution Degree 2. Category II includes local level, 

appliance, portable equipment, etc., with transient overvoltages less than Overvoltage Category III.

TM100        Issue No:2(I) -  18/06/14

Original Language Version

 © Jack Sealey Limited

Summary of Contents for TM100

Page 1: ...use store the multimeter carefully in a safe dry childproof location out of direct sunlight Storage temperature range 20 C to 60 C ALWAYS turn off the power and disconnect the test leads before opening the cover to replace the fuse or batteries The warnings cautions and instructions referred to in this manual cannot cover all possible conditions and situations that may occur It must be understood ...

Page 2: ... Jack 4 COM Jack 5 Positive Jack 6 Note Tilt stand fuse and battery compartment are on rear of unit 1 2 3 4 5 SYMBOLS AND ANNUNCIATORS Continuity Diode Test µ Micro amps m Milli volts amps k Kilo ohms Ω Ohms VDC Volts Direct Current VAC Volts Alternating Current ADC Amps Direct Current BAT Battery Test 1 4 BATTERY INSTALLATION WARNING To avoid electric shock disconnect the test leads from any sour...

Page 3: ...ound if the resistance is less than approximately 30Ω Battery Test Current 9V 6mA 1 5V 100mA Input Impedance 1MΩ ACV Bandwidth 45Hz to 450Hz DCA Voltage Drop 200mV Display 3 digit 2000 count LCD 1 1 digits Overrange Indication I is displayed Polarity Automatic no indication for positive polarity Minus sign for negative polarity Measurement Rate 2 times per second nominal Low Battery Indication BAT...

Page 4: ...has voltage on it Make sure the probe tips are touching the metal contacts inside the outlet before assuming that no voltage is present CAUTION Do not measure AC voltages if a motor on the circuit is being switched ON or OFF Large voltage surges may occur that can damage the meter 4 2 1 Set the function switch to the highest V AC position 4 2 2 Insert the black test lead banana plug into the negat...

Page 5: ...of the proper size and value 0 5A 250V fast blow for the 200mA range 10A 250V fast blow for the 10A range 5 2 6 Replace the fuse cover back in place Insert the screw and tighten it securely WARNING To avoid electric shock do not operate your meter until the fuse cover is in place and fastened securely 5 3 Clean the multimeter s casing using a slightly dampened cloth and mild detergent do not use a...

Page 6: ... authority guidelines TM100 Issue No 2 I 18 06 14 Original Language Version REMOVE SCREWS TO ACCESS BATTERY AND FUSES fig A Under the Waste Batteries and Accumulators Regulations 2009 Jack Sealey Ltd are required to inform potential purchasers of products containing batteries as defined within these regulations that they are registered with Valpak s registered compliance scheme Jack Sealey Ltd s B...

Reviews: