4.18.6.  To install the logging application browse to the CD-ROM and double click "9995USB_4.0.exe". Then follow these steps:

·

Click "Next" on the first screen of the setup Wizard, enter something in the "User" and "Company" fields, click "Next".

·

Leave the "Install 9995 to" location on "C:\Program Files\9995", click "Next".

·

On the next screen click "Next" and the same on the following screen.

·

The program will be installed, when done click "Finished".

4.18.7.  To run the program go to "All programs" within the "Start" menu and find "9995" and select "9995.exe".

4.18.8.  Click button "A" (FIG.5) to toggle between available COM ports until the COM# in window "B" (FIG.5) matches the number found in the device manager in

step 4.18.5.

fig.5

The program is now ready to capture data from the TA203.V2. 
For more details on using the program please refer to the document located in "C:\Program Files\9995" called "9995.rtf".

Summary of Contents for TA203.V2

Page 1: ...om Terminal 8 mA Terminal 9 20A Terminal 10 Range CYL Button 11 TRIG Button 12 Mode RPM 2 4 stroke Button INSTRUCTIONS FOR DIGITAL AUTOMOTIVE ANALYSER 15 FUNCTION BAR GRAPH PC LINK MODEL TA203 V2 Thank you for purchasing a Sealey product Manufactured to a high standard this product will if used according to these instructions and properly maintained give you years of trouble free performance 1 SAF...

Page 2: ...eading 7 digits DC Voltage Auto Ranging AC Voltage Auto Ranging except 400mV Input Impedance 10MΩ Maximum Input 700Vac rms or 1000Vdc DC Current Auto Ranging for uA and mA Input Impedance 10MΩ Frequency Range 50 to 400Hz Maximum Input 750Vac rms or 100Vdc Overload Protection 0 5A 250V and 20A 250V Fuse Maximum Input 400mAac rms or 400mAdc on uA mA ranges 20A ac rms or dc on 10A range AC Current Au...

Page 3: ...h or unstable Note The Trigger level has five steps and is different for each function combination 4 6 MAX MIN RS232 fig 1 2 4 6 1 Press the MAX MIN to enter MAX MIN mode Note MAX MIN function is only available in the manual range 4 6 2 Select the proper test range before activating the MIN MAX button to ensure that the MIN MAX reading will not exceed the testing range 4 6 3 Press once to select M...

Page 4: ...as an adjustable sensitivity switch that may also be used to correct an unstable reading 4 16 Dwell Angle Measurement Dwell angle is the number of degrees through which the distributor cam rotates while the breaker points are closed 4 16 1 Insert the black test lead into the negative COM jack and the red test lead into the positive V jack 4 16 2 Turn the rotary switch to the dwell position 4 16 3 ...

Page 5: ...nd the same on the following screen The program will be installed when done click Finished 4 18 7 To run the program go to All programs within the Start menu and find 9995 and select 9995 exe 4 18 8 Click button A FIG 5 to toggle between available COM ports until the COM in window B FIG 5 matches the number found in the device manager in step 4 18 5 fig 5 The program is now ready to capture data f...

Page 6: ...tion Parts 1 TA203 V2 01 TEMPERATURE PROBE 2 TA203 V2 02 TEST LEADS 3 TA203 V2 03 CROCODILE CLIPS 4 TA203 V2 04 HOLSTER 5 TA203 V2 05 CABLE USB 6 TA203 V2 06 INDUCTIVE PICK UP 7 TA203 V2 07 CARRY CASE NOTE It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice IMPORTANT No liability is accepted for inc...

Reviews: