background image

5.  Maintenance

5.1.    

The lifetime of a filter depends on many factors including the work rate, the airflow and the concentration of the contaminant in the  

 

atmosphere. A gas filter should be changed immediately when chemical breakthrough of a contaminant is detected by smell, taste  

 

or any other means. A dust filter should be changed when breathing becomes impaired. The exterior of the filter can be cleaned    

 

with the use of a damp cloth. Solvents must not be used and care should be taken to ensure no water enters the filter. Cleaning of  

 

the filter does not extend its life.

5.2.    

cleaninG the reSPirator.

 

After each work period (shift, or working day, etc.) the respirator must be cleaned and prepared for the next period of use. When the  

 

filter is being replaced it is a good opportunity to disassemble the respirator and thoroughly clean it. No special tools are required to  

 

remove any of the components from the face-piece.

5.2.1.   

The outer surfaces of the respirator may be cleaned using a cloth dampened with warm soapy water, then dried using a dry cloth.

 

8

  

Do not

 AlloW WATeR To GeT InTo THe FIlTeR.

5.2.2.   

Clean the respirator components using warm soapy water.

 

8

  

Do not

 USE DETERGENTS, THINNERS, SOLVENTS OR PETROLEUM-BASED DISINFECTANTS. TAKE GREAT CARE NOT   

  To dAMAGe THe RUBBeR SeAl on THe InSIde oF THe FIlTeR HoldeR WHIlST CleAnInG.

5.2.3.   

Inhalation and exhalation valves must be cleaned carefully. 

Do not

 stretch or distort the valves as this may cause incorrect  

 

 

sealing. Wipe the inside surface of the mask using a mild antiseptic solution, and dry with a clean cloth.

 

IF AnY deTeRIoRATIon oF VAlVe dIAPHRAGM oR oTHeR RUBBeR CoMPonenTS IS VISIBle, RePlACe IMMedIATelY.

5.2.4.   

Rinse in clean, cool water, shake off any surplus water, wipe with a clean dry cloth and allow to dry naturally.

5.2.5.   

Once the components are clean and dry, re-assemble the respirator in correct order.

5.2.6.   

Fit the correct new filter.

5.3.    

StoraGe

 

Filters should be stored in a dry cool environment away from direct sunlight and contamination. When not in use or during  

 

 

transportation this filter should be stored in a container such that it is out of direct sunlight, away from chemicals and    

 

 

abrasive substances and cannot be damaged by physical contact with hard surfaces/items.

Sealey Group, Kempson Way, Suffolk Business Park, Bury St edmunds, Suffolk. iP32 7ar

 01284 757500 

 01284 703534 

 [email protected] 

 www.sealey.co.uk

environMent Protection

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 

according to local regulations.

note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice.

important

: No Liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.