Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND

CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY

CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

INSTRUCTIONS FOR:

SURFACE MOUNTED WATER PUMP

Model:

SMP60

p

p

p

WARNING! THIS PUMP MUST BE INSTALLED AND TESTED BY A QUALIFIED ELECTRICIAN. See installation.

Once installed, the following tests and checks must be regularly undertaken:

1.1.

ELECTRICAL SAFETY. 

p

p

 

 

WARNING! It is the user’s responsibility to read, understand and comply with the following:

You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and

all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety

devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD

(Residual Current Device) is used with all electrical products. It is particularly important to use an RCD together with portable products that are

plugged into an electrical supply not protected by an RCCB. If in doubt consult a qualified electrician. You may obtain a Residual Current Device

by contacting your Sealey dealer. 

You must

also read and understand the following instructions concerning electrical safety.

1.1.1. The 

Electricity At Work Act 1989

requires all portable electrical appliances, if used on business premises, to be tested by 

a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2. The 

Health & Safety at Work Act 1974

makes owners of electrical appliances responsible for the safe condition of the appliance 

and the safety of the appliance operator. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3. Ensure the insulation on all cables and the product itself is safe before connecting to the mains power supply. 

1.1.4. Ensure that cables are always protected against short circuit and overload.

1.1.5. Regularly inspect power supply, leads, plugs for wear and damage and inspect power connections, to 

ensure that none is loose. 

1.1.6.

Important:

Ensure the voltage marked on the product is the same as the electrical power supply

to be used and check that plugs are fitted with the correct capacity fuse. A 13 amp plug may require 

a fuse smaller than 13 amps for certain products (

subject to 1.1.10. below)

see fuse rating at right. 

1.1.7. DO NOT pull or carry the powered appliance by its power supply lead. 

1.1.8. DO NOT pull power plugs from sockets by the power cable.

1.1.9. DO NOT use worn or damaged leads, plugs or connections. Immediately replace or have repaired by 

a qualified electrician. A U.K. 3 pin plug with ASTA/BS approval is fitted. In case of damage, cut off 

and fit a new plug according to the following instructions (discard old plug safely).

(UK only - see diagram at right). 

Ensure the unit is correctly earthed via a three-pin plug. 

a)  Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

b) Connect the BROWN live wire to live terminal ‘L’.

c)  Connect the BLUE neutral wire to the neutral terminal ‘N’.

d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable external

insulation extends beyond the cable restraint and that the restraint is tight.

1.1.10.

Extension cable use. Only use a cable designed for use with water equipment. Contact your dealer or a qualified electrician

for advice. Ensure water is kept clear of electrical mains power supply. DO NOT touch switch or plug with wet hands.

1. SAFETY INSTRUCTIONS

Blue

Neutral 

Wire

Yellow & Green 

Earth Wire 

Cable 

Restraint

FUSE RATING

5 AMP

Brown

Live 

Wire

SMP60 - 2 - 211101

2. INTRODUCTION & SPECIFICATION

This pump is designed for pumping clean cold or warm water, (NOT exceeding 35

O

C) to supply domestic, agricultural or light industrial use. Typical use would be

for filling tanks, wells, large ponds, swimming pools, irrigation and the general transfer of water. The pump may also be used to circulate water. 

Model

Power

Max. Head 

Max. Flow

Performance

Outlet Pipe Bore

Length x Width x Height

Flow @ Head

SMP60

800W

43m 

60 l/min

25mm (1”) 

370 x 190 x 225mm

10l/min @ 39m

50l/min @ 6m

1.2.

GENERAL SAFETY

p

WARNING! 

Pump must be used in accordance with Health & Safety, government, local authority and water authority rules and regulations.

3

Familiarise yourself with the application, limitations and potential hazards peculiar to the pump.

p

WARNING!

Disconnect the pump from the mains power before servicing or performing any maintenance.

3

Maintain the pump in good condition (use an authorised service agent). Keep the pump clean.

3

Replace or repair damaged parts. 

Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

3

Only use for pumping clean, cold or warm water (NOT exceeding 35

O

C).

3

If used in situations of possible flooding, user is responsible for installing appropriate back up procedures, alarms etc. in case of pump failure.

3

If used with swimming pools, fish ponds, etc., ensure areas are clear of people and animals (including removal of fish from ponds). Note that this pump is not

designed for continuous use in a fish pond or similar water feature or display.

8

DO NOT operate the pump if any parts are damaged or missing as this may cause failure and/or possible personal injury.

8

DO NOT use the pump for any purpose other than for which it is designed.

8

DO NOT use to pump chemicals, fuels, fatty liquids or salt water.

8

DO NOT pump sludge, sand, gravel, mud, or fibrous materials. Ensure the inlet hose will NOT pick up any solid 

materials. Sand and such substances will reduce working life of pump, and invalidate your warranty.

8

DO NOT use to pump septic tanks or settling pits. 

8

DO NOT submerge the pump or the electrical cable in water. Protect the pump from external wet conditions.

8

DO NOT operate pump during freezing temperatures. DO NOT allow any part of the pump or pipes to freeze.

8

DO NOT carry pump by the cable, or piping. Use only the handle.

3

When not in use switch off pump, remove plug from power supply and drain out any water.

p

WARNING! 

DO NOT allow uncontrolled discharge of contaminated water, thus polluting the environment.

Reviews: