5. OPERATION

The lathe may now be operated as before, but with the accuracy and convenience of digital measurement. 

There are three buttons present on each display:

In/mm   Switches display between inch and mm.

ON/OFF  Turns the unit on or off.

ZERO   Sets the display to 0.

5.1   Turn both displays on by pressing the ON/OFF button on each one. 

5.2   Select the required unit of measurement for each display, using the In/mm buttons. 

5.3   Set up the lathe as required and zero the displays using the ZERO buttons (the displays can be reset to 0 at any time) 

5.4   When you are finished working on the lathe, turn both displays off by pressing the ON/OFF button on each one. 

6. MAINTENANCE 

6.1  The SM3002DFD requires little by way of maintenance. Keep the displays clean by occasionally wiping with a moist cloth - DO NOT use 

 

solvents or abrasives. 

6.2   Should the display begin to fade during use, the batteries must be replaced. Each display requires one LR44 battery.

6.2.1   Remove the two screws (fig 21a) and the battery compartment cover (fig 21b) 

6.2.2  Gently pull the yellow tag to eject the battery.

6.2.3  Insert a new battery (type LR44) into the battery compartment, with the positive (+) side facing up towards the LCD. 

fig 21

fig 22

NOTE:

 

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

a

b

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

© Jack Sealey Limited

    Original Language Version 

  SM3002DFD     Issue: Issue: 2(L) - 12/05/16

Summary of Contents for SM3002DFD

Page 1: ... to remove the top of the compound rest from the compound rest bottom 3 2 Undo the handle screw of the graduated scale fig 2a and remove the spring clip and scale fig 2b Remove the compound rest screw retainer fig 2c retaining the fixing screws for future use and remove the compound rest feed screw 3 3 Remove the two large hex screws fig 3a retaining them for future use Remove the compound rest bo...

Page 2: ... the screw fits tightly and correctly into the slot on the feed screw 4 INSTALLATION 2 Installing the Cross Slide digital display 4 1 Remove the two socket head cap screws that retain the cross slide feed nut 4 2 Remove the cross slide feed nut fig 12a by turning the cross slide feed handle clockwise 4 3 Remove the cross slide feed handle fig 13a the spacer washer and the dial fig 13b fig 7 fig 8 ...

Page 3: ...ew Install the retaining screws provided do not overtighten 4 8 Install the spacer washer provided fig 18a and the cross slide rest feed handle 4 9 Fit the new cross slide feed nut fig 19a on the cross slide feed screw The screw holes in the nut must be facing upwards 4 10 Rotate the handle anticlockwise to draw the feed nut along the feed screw until the screw holes in the nut are aligned with th...

Page 4: ...th DO NOT use solvents or abrasives 6 2 Should the display begin to fade during use the batteries must be replaced Each display requires one LR44 battery 6 2 1 Remove the two screws fig 21a and the battery compartment cover fig 21b 6 2 2 Gently pull the yellow tag to eject the battery 6 2 3 Insert a new battery type LR44 into the battery compartment with the positive side facing up towards the LCD...

Reviews: