Sealey SM19.V3 Quick Start Manual Download Page 2

 

9

  

Avoid unintentional starting. Ensure the switch is in the off position before plugging into mains supply.

 

8

  

DO NOT

 overfill tank or allow fluid level to fall below pump inlet.

 

8

  

DO NOT

 use the tank for a task it is not designed to perform.

 

8

  

DO NOT

 operate the tank if any parts are damaged or missing as this may cause failure and/or personal injury.

 

8

  

DO NOT

 allow untrained persons to operate the tank.

 

8

  

DO NOT

 operate the tank when you are tired or under the influence of alcohol, drugs or intoxicating medication.

 

8

  

DO NOT

 leave the tank operating unattended.

 

9

   When not in use switch off the tank, close the lid and remove the plug from the power supply. 

 

9

  

Dispose of waste liquids in accordance with local authority regulations.

 

‰

  

WARNING!

 Protect the environment - 

DO NOT

 allow uncontrolled discharge of pollutants.

 

9

 

 

Keep the tank clean for best and safest performance. 

N

2.  INTRODUCTION

Heavy-duty one-piece tank. Fully sealed electric motor with magnetic drive pump unit. Lid features self-latching fusible link which automatically 

snaps lid shut in the event of a fire. Includes removable shelf and small parts basket. Flexible metal nozzle directs solvent over work. Supplied 

with workshop stand with integral storage shelf.

3.  SPECIFICATION

Model no .................................................................

SM19.V3

M

aximum Working Capacity:

 ............................................

50L

Minimum working Capacity: .............................................

40L

O

verall Dimensions (W x D x H):

 .............

775 x 540 x 960mm

P

ump Output/hr:

 .............................................................

200L

Supply: ...........................................................................

230V

T

ank Dimensions (W x D x H):

 ................

775 x 540 x 265mm

4.  ASSEMBLY

  

4.1.    

Refer to attached Parts Diagram.

4.2. 

  

Remove parts from packing and take items out of the tank. Before assembly check parts to ensure they are complete and not damaged.

4.3. 

   

Close lid of tank, gently and turn unit upside down. 

Rest tank on a clean soft surface (i.e. cardboard) ensuring lid is secured in the closed  

 position.

4.4. 

     Attach each of the 4 tank legs (13) with 4 sets each of 6mm screws, lockwashers and nuts (14,8,9) to the brackets on the tank (7) unit.

4.5. 

  

Attach shelf (12) to holes located mid-way of 4 legs with 2 sets each of 6mm screws, lockwashers and nuts (14,8,9). 

4.6. 

  

Return the tank unit to the upright position on its legs and open the spring tensioned tank cover (1).

4.7. 

  

Thread the fitting of the flexible metal pipe (24) fluid outlet tube onto the pump elbow (13), fig.1. Place the pump housing lid (29) over the  

 

open pump housing (20) with fluid intake perforations and raised ribs downward and over pump fig.2. Snap into place.

4.8. 

  

Route the power cord of the pump housing assembly through the rectangular opening on the side of the tank unit (7) with the inlet filter  

 

(28) downward and facing inward, fig’s.3 & 4.

4.9. 

  

The power switch is visible through the rectangular opening. Hook the raised offset tab on the rear of the pump housing (20) over the

 

bottom edge of the rectangular opening fig.4.

4.10. 

C

heck to see that the tank plug (11) plug is tightly installed.

4.11. 

P

lace the work shelf (6) over the edges on the walls of the tank (7).

4.12. 

M

ake sure the nozzle of the flexible pipe (24) is facing in toward the centre of the tank (7) and downward.

4.13. 

Installation of a flow-through parts cleaning brush and hose extension is optional. 

4.14. 

F

ill unit with suitable, water-based degreasing solution sufficiently to cover the entire inlet filter (28) (approx.12 gallons). 

 

Important Note: Follow degreasing solution mixing, usage and safety label instructions carefully before using.

4.15. 

Plug power lead into mains supply.

4.16. 

Turn Power Switch to the “On” position.

5.  OPERATION

 

‰

  

WARNING! Wear safety clothing, eye protection and gloves and ensure you read, understand and apply the safety instructions  

 

in Section 1.

5.1. 

  

Ensure the unit is located on a firm level surface in a well ventilated area and is switched off and unplugged from the mains power supply.

5.2. 

  

Fill the tank with Sealey solvent - approx. 50 litres. Minimum level 

must

 cover pump inlet - approx. 40 litres. Follow the solvent  

 

 

instructions on the packaging.

 

8

 

 

DO NOT

 fill with flammable solvents such as paraffin, thinners, etc.

Original Language Version

© Jack Sealey Limited

S

M19.V3  Issue:1       17/06/22

fig.1

fig.2

fig.3

fig.4