background image

  6.  OPERATION

Original Language Version

SAC9000.V2   Issue No.1 19/01/10

5.8  DISPLAY SCREEN:

 

1

. . . . . . . . . . . . . . COOLING MODE INDICATOR   

 

2

 . . . . . . . DEHUMIDIFYING MODE INDICATOR   

 

3

 . . . . . . . . . . . . . . . . TIMER MODE INDICATOR   

 

4

 . . . . . . . . . . . . . COOLING MODE INDICATOR   

 

5

 . . . . . . . . . . . . . . . . TEMPERATURE DISPLAY   

 

 

6

 . . . . . . . . . . . . . . . .SLEEP MODE INDICATOR   

 

7

 . . . . . . . . . . . . . . . . WATER FULL INDICATOR   

 

8

 . . . . . . . . . . . . . . . . . . FAN MODE INDICATOR   

 

9

 . . . . . . . . . . . . . .HEATING MODE INDICATOR   

 

10

 . . . . . . . . . . . . . . . . . . . . . . LOW FAN SPEED   

 

10 + 11

 . . . . . . . . . . . . . . . . . .HIGH FAN SPEED   

6.1 

STANDBY MODE.

 When the machine is plugged in, the two centre segments of the display will light up to 

 

indicate standby mode. When the machine is first switched on it will start up in cooling mode, set at 22ºC, with a  

 

low fan speed. The machine mode can now be changed using the mode key. When the ON/OFF switch is    

 

pressed again the machine returns to standby mode. If the machine remains in standby mode and is switched  

 

on again it will start up in the last mode selected. If the machine is disconnected from the mains it will start up in  

 

the default cooling mode when next used.

6.2 

COOLING MODE.

 Press the MODE key to cycle through the options until cooling mode is reached indicated by  

 

the snowflake symbol. (fig.7-1).

6.2.1  Press UP or DOWN to adjust the temperature.

6.2.2  Press FAN to select a higher or lower fan speed.   

6.3 

HEATING MODE.

 Press the MODE key to cycle through the options until heating mode is reached indicated by  

 

the sun symbol. (fig.7-9).

6.3.1  Press UP or DOWN to adjust the temperature.

6.3.2  Press FAN to select a higher or lower fan speed.

6.4 

FAN ONLY MODE.

 Press the MODE key to cycle through the options until fan mode is reached indicated by the  

 

fan symbol. (fig.7-8).

6.4.3  Press the FAN key to switch between a low or high fan speed.

6.5 

TIMER MODE.

 In standby mode press TIMER to set the switch ON time (the timer symbol lights).

6.5.1  Repeatedly press the timer key to advance the time in one hour increments from 1 to 24 hours. Stop when you  

 

reach the required switch on time.

6.5.2  To set the power OFF time the machine must be running. The time set will remain valid for all modes.

6.5.3  Press TIMER to set the power OFF time (the timer symbol lights).

6.5.4  Repeatedly press the timer key to advance the time in one hour increments from 1 to 24 hours. Stop when you  

 

reach the required switch off time.

6.5.5  When the machine is returned to standby mode the timer settings are cancelled.

 

6.6 

DEHUMIDIFYING MODE.

 Press the MODE key to cycle through the options until dehumidifying mode is    

 

reached indicated by the water droplets symbol. (fig.7-2).

6.6.1  The timer and sleep functions cannot be set in dehumidifying mode.

6.6.2  The fan speed is automatically selected at low and cannot be changed.

6.7 

SLEEP FUNCTION.

  Press the SLEEP key to start the SLEEP function indicated by the moon symbol. (fig.7-6).

 

The default fan speed is low. The sleep function is only valid in COOLING mode and HEATING mode. In stand 

 

by and water full conditions, sleep mode is automatically cancelled.

6.7.1  In COOLING mode, the sleep function turns the temperature up by 1°C, one hour after the sleep function is   

 

turned on. The temperature then remains constant.

6.7.2  In HEATING mode, the sleep function turns the temperature down by 1°C, one hour after the sleep function is  

 

turned on. The temperature then remains constant.

Fig.7

Summary of Contents for SAC9000.V2

Page 1: ... 1 1 1 and 1 1 2 and use a Portable Appliance Tester 1 1 4 Ensure that cables are always protected against short circuit and overload 1 1 5 Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none is loose 1 1 6 Important Ensure that the voltage marked on the appliance matches the power supply to be used and that the plug is fitted with the c...

Page 2: ...DO NOT allow the unit to get wet as this may cause an electric shock and will damage the unit DO NOT let the power lead touch a hot surface lie in a hot airflow or run under a carpet DO NOT insert or allow objects to enter any openings of unit as this may cause an electric shock fire or damage to unit DO NOT use in bathroom shower room or in any environment of excessive condensation DO NOT use the...

Page 3: ...iency of the unit 4 2 Seal Plate placement See fig 3F Identify a suitable window which can be vertically or horizontally opened Match the window opening to the height of the seal plate Slide the inner part of the seal plate out until it matches the width of the window and lock the two parts together by tightening the screws on the inside edge of the inner slide Permanently screw the seal plate to ...

Page 4: ... on this key selects between high and low fan speed 5 4 UP Under COOLING or HEATING mode press this key to raise the temperature 16 to 31 C 5 5 DOWN Under COOLING or HEATING mode press this key to lower the temperature 16 to 31 C 5 6 SLEEP Under COOLING or HEATING mode press this key to turn the sleep function ON or OFF 5 7 TIMER Under power ON or standby mode press this key to set the ON OFF time...

Page 5: ...fan mode is reached indicated by the fan symbol fig 7 8 6 4 3 Press the FAN key to switch between a low or high fan speed 6 5 TIMER MODE In standby mode press TIMER to set the switch ON time the timer symbol lights 6 5 1 Repeatedly press the timer key to advance the time in one hour increments from 1 to 24 hours Stop when you reach the required switch on time 6 5 2 To set the power OFF time the ma...

Page 6: ...he assembled connector fig 8 4 onto the water outlet and push the drain tube fig 8 5 onto the connector See fig 8 above WARNING Switch off the machine and unplug it from the mains power supply before performing any maintenance or repairs 8 1 CLEANING 8 1 1 Remove the plug from the mains power supply 8 1 2 Use a soft damp cloth to clean the machine outer casing Don t use chemical agents such as ben...

Page 7: ... from room Filters too dirty Clean or replace filters Air inlets or air outlet is blocked Remove blockage Machine too noisy Machine is not situated on level ground Move to flat and solid ground Compressor not working Compressor heat protection cut out operated Wait for 3 minutes restart the machine when temperature normal Environmental Protection Recycle unwanted materials instead of disposing of ...