background image

  3.  CONTENTS/MAIN FEATURES

  2.  SPECIFICATION

1.2 

GENERAL SAFETY

 

Disconnect the unit from the mains power before servicing or cleaning.

 

Maintain the

 

unit in good order and clean condition for best and safest performance.

  Replace or repair damaged parts. 

Use recommended parts and an

 

authorised service agent

.

 Unauthorised parts  

 

may be dangerous and will invalidate the warranty.

  Locate the unit in a suitably sized room for its capacity, keep the immediate area in front of the outlet grille clean  

 

and tidy and free from unrelated materials.

 

DO NOT use the unit near gas appliances, fires or in the vicinity of flammable liquids, solids or gases such as    

 

petrol, solvents, aerosols etc, or where heat sensitive materials may be stored.

 

DO NOT block the air intake or outlet by placing the unit too close to walls or furniture.

 

DO NOT cover the unit when in use, and do not obstruct the air inlet and outlet grilles with items such as clothing,  

 

soft furnishings, furniture, bedding etc.

 

DO NOT use the heater for any purpose other than that for which it is designed.

 

DO NOT allow the unit to get wet as this may cause an electric shock, and will damage the unit.

 

DO NOT let the power lead touch a hot surface, lie in a hot airflow, or run under a carpet.

 

DO NOT insert or allow objects to enter any openings of unit as this may cause an electric shock,

 

fire or damage to unit.

 

DO NOT use in bathroom, shower room, or in any environment of excessive condensation.

 

DO NOT use the unit out of doors. This unit is designed for indoor use only.

 

DO NOT use the unit if incorrectly working, or has become wet or has sustained any other type of damage. 

 

DO NOT allow children to operate the unit.

  When not in use, disconnect from the mains and store in a safe, cool, dry, childproof area.

  Keep the unit one metre away from TV sets or radios to avoid electromagnetic interference.

  Keep the unit level when moving it from one place to another.

 

DO NOT subject the unit to vibration, shocks or impact.

 

DO NOT use the unit in a very crowded room.

Model No: . . . . . . . . . . . . . . . . . . . . . . . . SAC9000.V2   

Cooling Capacity:  . . . . . . . . . . . . . . . . . . . 10000Btu/hr   

Heater: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1100W   

Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V

Maximum Air Flow: . . . . . . . . . . . . . . . . . . . 400mtr³/hr   

Maximum Water Extraction Rate: . . . . . . . . . . .1.2ltr/hr   

Thermostat Range: . . . . . . . . . . . . . . . . . . . . . 16-31°C   

Refrigerant: . . . . . . . . . . . . . . . . . . . . . . . . . . . . R410A   

Exhaust hose length . . . . . . . . . . . . . . . . . . . .1500mm

Energy class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A

Fig.1

Original Language Version

SAC9000.V2   Issue No.1 19/01/10

Fig.1

Fig.2

Summary of Contents for SAC9000.V2

Page 1: ... 1 1 1 and 1 1 2 and use a Portable Appliance Tester 1 1 4 Ensure that cables are always protected against short circuit and overload 1 1 5 Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none is loose 1 1 6 Important Ensure that the voltage marked on the appliance matches the power supply to be used and that the plug is fitted with the c...

Page 2: ...DO NOT allow the unit to get wet as this may cause an electric shock and will damage the unit DO NOT let the power lead touch a hot surface lie in a hot airflow or run under a carpet DO NOT insert or allow objects to enter any openings of unit as this may cause an electric shock fire or damage to unit DO NOT use in bathroom shower room or in any environment of excessive condensation DO NOT use the...

Page 3: ...iency of the unit 4 2 Seal Plate placement See fig 3F Identify a suitable window which can be vertically or horizontally opened Match the window opening to the height of the seal plate Slide the inner part of the seal plate out until it matches the width of the window and lock the two parts together by tightening the screws on the inside edge of the inner slide Permanently screw the seal plate to ...

Page 4: ... on this key selects between high and low fan speed 5 4 UP Under COOLING or HEATING mode press this key to raise the temperature 16 to 31 C 5 5 DOWN Under COOLING or HEATING mode press this key to lower the temperature 16 to 31 C 5 6 SLEEP Under COOLING or HEATING mode press this key to turn the sleep function ON or OFF 5 7 TIMER Under power ON or standby mode press this key to set the ON OFF time...

Page 5: ...fan mode is reached indicated by the fan symbol fig 7 8 6 4 3 Press the FAN key to switch between a low or high fan speed 6 5 TIMER MODE In standby mode press TIMER to set the switch ON time the timer symbol lights 6 5 1 Repeatedly press the timer key to advance the time in one hour increments from 1 to 24 hours Stop when you reach the required switch on time 6 5 2 To set the power OFF time the ma...

Page 6: ...he assembled connector fig 8 4 onto the water outlet and push the drain tube fig 8 5 onto the connector See fig 8 above WARNING Switch off the machine and unplug it from the mains power supply before performing any maintenance or repairs 8 1 CLEANING 8 1 1 Remove the plug from the mains power supply 8 1 2 Use a soft damp cloth to clean the machine outer casing Don t use chemical agents such as ben...

Page 7: ... from room Filters too dirty Clean or replace filters Air inlets or air outlet is blocked Remove blockage Machine too noisy Machine is not situated on level ground Move to flat and solid ground Compressor not working Compressor heat protection cut out operated Wait for 3 minutes restart the machine when temperature normal Environmental Protection Recycle unwanted materials instead of disposing of ...