1.1.   ELECTRICAL SAFETY

 

 

  

WARNING!

 It is the responsibility of the owner and the  

 

   

operator to read, understand and comply with the following: You  

   

must check all electrical products, before use, to ensure that    

   

they are safe. You must inspect power cables, plugs, sockets    

   

and any other connectors for wear or damage. You must ensure  

   

that the risk of electric shock is minimised by the installation of   

   

appropriate safety devices. A Residual Current Circuit Breaker   

   

(RCCB) should be incorporated in the main distribution board.   

   

We also recommend that a Residual Current Device (RCD) is    

   

used. It is particularly important to use an RCD with portable    

   

products that are plugged into a supply which is not protected by  

   

an RCCB. If in any doubt consult a qualified electrician. You may  

   

obtain a Residual Current Device by contacting your Sealey    

   

dealer. You must also read and understand the following  

 

   

instructions concerning electrical safety.

1.1.1. The 

Electricity at Work Act 1989

 requires that all portable  

 

   

electrical appliances, if used on business premises, are tested   

   

by a qualified electrician, using a Portable Appliance Tester  

 

   

(PAT), at least once a year.

1.1.2. The 

Health & Safety at Work Act 1974

 makes owners of  

 

   

electrical appliances responsible for the safe condition of those  

   

appliances and the safety of the appliance operators. 

If in any   

   doubt about electrical safety, contact a qualified electrician.

1.1.3.  Ensure that the insulation on all cables and on the appliance is   

   

safe before connecting it to the power supply. See 1.1.1. and    

   

1.1.2. and use a Portable Appliance Tester.

1.1.4.  Ensure that cables are always protected against short circuit    

   

and overload.

1.1.5.  Regularly inspect power supply cables and plugs for wear or    

   damage and check all connections to ensure that none is loose.

1.1.6. 

Important:

 Ensure that the voltage marked on the appliance    

   

matches the power supply to be used and that the plug is fitted  

   

with the correct fuse (see 1.1.10. below).

1.1.7. 

DO NOT

 pull or carry the appliance by the power cable.

1.1.8. 

DO NOT

 pull the plug from the socket by the cable.

1.1.9. 

DO NOT

 use worn or damaged cables, plugs or connectors.    

   

Immediately have any faulty item repaired or replaced by a  

 

   

qualified electrician.    

 

1.1.10. A 32amp supply is required and we recommend that a 32amp    

   

industrial round pin plug should be fitted and connected to a    

   

32amp supply having a Type C breaker. 

If in doubt, you must  

   contact a qualified electrician to ensure that a suitably rated  

   

supply is available.

 

    

IMPORTANT!

  The use of extension leads to connect these    

   

compressors to the mains is not recommended as the resulting  

   

voltage drop reduces motor, and therefore pump performance.

1.2.   GENERAL SAFETY 

3   

Familiarise yourself with the application and limitations of the    

   

compressor.   

 

3   

Ensure the compressor is in good order and condition before    

   

use. If in any doubt do not use the unit and contact an  

 

   

electrician/service agent.

   

WARNING! Compressor must only be serviced by an  

 

   

authorised agent. DO NOT tamper with, or attempt to adjust,  

   

pressure switch or safety valve.

3   

Before moving, or maintaining the compressor ensure it is  

 

   

unplugged from the mains supply and that the air tank pressure  

   

has been vented. 

3   

Maintain the compressor in good condition and replace any    

   

damaged or worn parts. Use genuine parts only. 

Unauthorised   

   

parts may be dangerous and will invalidate your warranty.

3   

Read the instructions relating to any accessory to be used  

 

   

with this compressor. Ensure the safe working pressure of  

 

   

any air appliance used exceeds compressor's output   

 

   

pressure. If using a spray gun, check that the area selected    

   

for spraying is provided with an air change system/ventilation.

 1.Tank

 2. Electric Motor 1

 3. Belt Guard

 4. Compressor Unit 1

 5. Compressor Unit 2

6. Electric Motor 2

7. Direct Air Outlet

8. Condensate Drain

9. Pressure Switch

10. Pressure Gauge

1. SAFETY

 

  

 

 Warning: 

Electricity

 

  

Warning: 

Hot Surface

 

  

 

   

Warning: 

Automatic

  

 

  

start up

 

 

  

Wear ear protection

  

Read the instruction  

  

manual before use

 

DO NOT

 open the air    

 

cock before an air hose  

 

is attached

 

  

 

DO NOT

 operate the    

 

compressor with 

 

enclosure displaced  

 

Ensure oil level is 

 

correct before first use 

  

 

Original Language Version

 © Jack Sealey Limited

 SAC4505555B,SAC5507575B    Issue: 1 - 17/12/14

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.  USE THE PRODUCT 

CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL 

INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions 

and properly maintained, give you years of trouble free performance.

Summary of Contents for SAC4505555B

Page 1: ...ectrician 1 1 10 A 32amp supply is required and we recommend that a 32amp industrial round pin plug should be fitted and connected to a 32amp supply having a Type C breaker If in doubt you must contact a qualified electrician to ensure that a suitably rated supply is available IMPORTANT The use of extension leads to connect these compressors to the mains is not recommended as the resulting voltage...

Page 2: ...essor from packaging and inspect for any shortages or damage If anything is found to be missing or damaged contact your supplier 3 2 Save the packing material for future transportation of the compressor It is recommended that the packing is stored in a safe location at least for the period of the guarantee Then if necessary it will be easier to send the compressor to the service centre 3 3 Confirm...

Page 3: ... 3 Turn switch B to start the compressor position 1 is compressor unit 1 operating only position 2 is compressor unit 2 operating only position 3 is both compressor units operating at the same time at staggered starting times 4 4 When starting the compressor for the first time leave it running with no air tools connected to the air outlet Make sure that the pressure in the tank rises and that the ...

Page 4: ...703534 sales sealey co uk Sole UK Distributor Sealey Group Kempson Way Suffolk Business Park Bury St Edmunds Suffolk IP32 7AR www sealey co uk W e b email fig 7 fig 8 Fault Cause Remedy Pressure drop in the tank Air leaks at connections Run compressor to max pressure switch off Brush soap solution over connections and look for bubbles Tighten connections showing leaks If problem persists contact A...

Page 5: ......

Page 6: ......

Reviews: