background image

100L BELT DRIVE AIR COMPRESSOR 3HP 

WITH FRONT CONTROL PANEL

MODEL NO: 

SAC3103B

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY

1.1. 

  

ELECTRICAL SAFETY

 

‰

   WARNING!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

 

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets    

 

and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of    

 

appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. You  

 

must also read and understand the following instructions concerning electrical safety.

 

9

   Ensure that cables are always protected against short circuit and overload.

 

9

   Regularly inspect power supply cables and plugs for wear or damage and check all connections  

  to ensure that none are loose.

 

9

   Ensure that the voltage marked on the appliance matches the power supply to be  

  used and that the plug is fitted with the correct fuse - see fuse rating at right.

 

8

  

DO NOT

 use worn or damaged cables, plugs or connectors. Have any faulty item repaired or  

  replaced immediately by a competent electrician.

 

9

   It is recommended that this device is wired directly to a fused isolator switch. If, however, a plug  

  is fitted, the following applies:

 

9

   Fit a new plug according to the following instructions (UK only).

 

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b) Connect the BROWN live wire to the live terminal ‘L’.

 

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

d) After wiring, check that there are no bare wires, that all wires have been correctly connected, 

 

    that the cable restraint is tight.

1.1.1. 

  

SAC3203B is supplied with a flying lead without a plug. Jack Sealey Limited recommend a 16 amp protected supply. When  

 

 

connecting to a 16 amp protected supply, contact a qualified electrician to ensure connection to a suitably rated  supply. Provided a    

 

good 230V supply is available and the lead length is not increased from that supplied, the compressor may operate from a  

 

 

13 amp supply. This very much depends upon the quality of your power supply.

1.1.2. 

  

Wiring a BS 1363/A UK 3 Pin Plug.

 

‰

   WARNING! 

If in doubt contact a qualified electrician. 

 

A) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

B) Connect the BROWN live wire to the live terminal ‘L’.

 

C) Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

D) Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

        

Sealey recommend that repairs are carried out by a qualified electrician.

1.2. 

  

GENERAL SAFETY

 

9

   Familiarise yourself with the application and limitations of the compressor.

 

9

   Ensure the compressor is in good order and condition before use. If in any doubt 

DO NOT

 use the unit and contact an electrician/   

  service agent.

 

‰

   WARNING! 

Compressor must only be serviced by an authorised agent.

 

8

  

DO NOT

 tamper with, or attempt to adjust, pressure switch or safety valve.

 

9

   Before moving, or maintaining the compressor ensure it is unplugged from the mains supply and that the air tank pressure has been  

 vented. 

 

9

   Maintain the compressor in good condition and replace any damaged or worn parts. Use genuine parts only. Unauthorised parts may  

  be dangerous and will invalidate your warranty.

Recommended fuse rating

13 Amp

SAC3103B  Issue 4 (3,4,5) 01/04/22

Original Language Version

© Jack Sealey Limited

Refer to 

instructions

WARNING:

High Voltage

 Wear eye 

protection

 WARNING:

Hot surface

 Wear ear 

protection

WARNING:

Automatic

startup

 Wear protective 

clothing

 WARNING

 WARNING:

Under pressure

 

Switch off

before servicing 

or maintenance

 Belt guard

must be in

place

 DO NOT

Connect face 

mask directly

to compressor 

 DO NOT

open the air

cock before

an air hose is

attached

Summary of Contents for SAC3103B

Page 1: ...t the BLUE neutral wire to the neutral terminal N d After wiring check that there are no bare wires that all wires have been correctly connected that the cable restraint is tight 1 1 1 SAC3203B is supplied with a flying lead without a plug Jack Sealey Limited recommend a 16 amp protected supply When connecting to a 16 amp protected supply contact a qualified electrician to ensure connection to a s...

Page 2: ...ckness at any point WARNING If an electrical fuse blows ensure it is replaced with an identical fuse type and rating 9 When not in use store the compressor carefully in a safe dry childproof location 9 When the compressor is not in use it should be switched off disconnected from the mains supply and the air drained from the tank 1 3 INSPECTION OF PRESSURE TANK BOTH INTERNAL AND EXTERNAL 1 3 1 Unde...

Page 3: ... start the compressor pulling the ON OFF button fig 3 upwards 5 7 4 Leave the compressor running with no air line or tools connected and regulated pressure gauge fig 5 set to maximum pressure fully clockwise Make sure that the pressure in the tank rises and that the compressor stops automatically when the maximum is reached This value is written on the specification plate and shown on the direct p...

Page 4: ...Replace filler cap B Check the automatic cut out at maximum pressure and the automatic cut in at 2bar below WARNING Never mix different oils and DO NOT use non detergent low quality oils as the compressor may be damaged WARNING Dispose of waste oil only in accordance with local authority requirements 6 6 OPERATIONS TO BE CARRIED OUT EVERY 500 HOURS A Replace air filter figs 1 4 B Check all tube fi...

Page 5: ...ste authority for recycling information Note It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice Important No Liability is accepted for incorrect use of this product Warranty Guarantee is 24 months from purchase date proof of which is required for any claim 4B Motor stops and will not restart Supply...

Reviews: