2.
i
introduction
T
hermostatically controlled unit with extendible exhaust hose and window kit - ideal for home or office environments. Features three-speed fan
and electronic remote control. Air conditioning temperature range 16-30°C. Also features heating and dehumidifying functions. Dehumidifier
capable of removing up to 33.6ltr/day. Refrigerant is R410A. Mounted on castors for manoeuvrability. Cable storage keeps unit tidy when not in
use.
3. sPecification
Cooling Capacity: ................................................
12000Btu/hr
Supply: ...........................................................................230V
Power: .........................................................................
1355W
m
aximum Airflow:
...................................................435mtr
3
/hr
m
aximum Water Extraction Rate:
..........................
33.6ltr/day
Refrigerant: ........................................................
R410A/620g
discharge Side Pressure:...........................................3.5mPa
Suction Side Pressure: ...............................................1.0mPa
exhaust Hose length: ..................................................1.5mtr
energy Class: .......................................................................A
W
eight: ........................................................................ 32.5kg
G
WP
..............................................................................
2088
Co
2
equivalent ............................................................. 1.295t
4. installation
4.1.
imPortant:
Allow the refrigerant to settle for at least two hours before using the unit.
4.2.
exhaust hose assembly
4.2.1.
Snap the two halves of the hose adaptor (fig.1.13) together (
do not
use excessive force).
4.2.2.
Pull one end exhaust hose (fig1.14) out from its closed position.
4.2.3.
Insert the end into the exhaust air outlet (fig.1.8) and turn in an anticlockwise direction until tight.
4.2.4.
Pull the free end out and screw the assembled hose adaptor onto the outer end of the exhaust hose in an anticlockwise direction until
tight.
4.3.
Window adapto
r
4.3.1.
Slide the window adaptor to the correct width for the window opening and locate the stop screw in the relevant screw hole to stop the
slide closing.
4.3.2.
Close the window onto the window adaptor, clamping it in place. This can be achieved with sash windows, sliding windows or vertically
hinged windows.
4.3.3.
Insert the hose adaptor into the window adaptor (figs 2 and 3).
4.4.
do not
use an extension hose or hose different from the one supplied. The length
and diameter of the hose supplied are the optimum size for this unit. Changing those
dimensions could affect the performance.
4.5.
location
The SAC12000 should be located on a flat floor and be 500mm clear of any surrounding objects.
fig.1
fig.2
fig.3
SAC12000.V2 Issue 2 29/08/18
Original Language Version
© Jack Sealey limited
S
AC 12000_V2 - Air Conditioner / Humidifier
T
his product contains fluorinated greenhouse gasses.
This product is hermetically sealed.
R
efrigerant: R410A (HFC32: 23% HFC125: 50%) 0.620g
G
WP : 2088
Co
2
equivalent : 1.295t