background image

RE97XS05

1

RE97XS05.01

NUT

2

RE97XS05.02

RAM

3

RE97XS05.03

SEAL WASHER

4

RE97XS05.04

U-CUP SEAL

5

RE97XS05.05

CYLINDER BASE

6

RE97XS05.06

QUICK COUPLER

RE97XS10

1

RE97XS10.01

NUT

2

RE97XS10.02

RAM

3

RE97XS10.03

SEAL WASHER

4

RE97XS10.04

U-CUP SEAL

5

RE97XS10.05

CYLINDER BASE

6

RE97XS10.06

QUICK COUPLER

RE97XS20

1

RE97XS20.01

NUT

2

RE97XS20.02

RAM

3

RE97XS20.03

SEAL WASHER

4

RE97XS20.04

U-CUP SEAL

5

RE97XS20.05

CYLINDER BASE

6

RE97XS20.06

QUICK COUPLER

RE97XS30

1

RE97XS30.01

NUT

2

RE97XS30.02

RAM

3

RE97XS30.03

SEAL WASHER

4

RE97XS30.04

U-CUP SEAL

5

RE97XS30.05

CYLINDER BASE

6

RE97XS30.06

QUICK COUPLER

Sole UK Distributor,

Sealey Group,

Bury St. Edmunds, Suffolk.

01284 757500

01284 703534

NOTE:

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required 

for any claim. 

INFORMATION: 

For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

RE97XS05, RE97XS10, RE97XS20, RE97XS30 - 1 - 091104

[email protected]

www.sealey.co.uk

e-mail

Web

4.

INSTRUCTIONS FOR USE

5.

MAINTENANCE

IMPORTANT:

Only fully qualified personnel should attempt maintenance or repair to the hydraulic system.

p

p

WARNING:

DO NOT use brake fluid, or any fluid other than hydraulic jack fluid, as this may cause 

serious damage to the pump/ram and will invalidate the warranty! Use only Sealey hydraulic oil.

5.2

General

Before each use check for damage to ram, pump, hose and accessories. If any suspect item is found 

remove from service and take necessary action to remedy the problem. 

Replace/repair with

genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty. 

Keep all parts of the kit clean - use only a mild detergent and a damp cloth. DO NOT use solvents. 

Note:  A small amount of oil around ram seal is normal - a thicker layer of oil may be deposited onto the ram

initially, due to the ram seals bedding in. 

Hydraulic coupling will weep a small amount of oil, particularly if ram is under pressure when coupling is 

released - this is normal. 

IMPORTANT: NO RESPONSIBILITY IS ACCEPTED FOR INCORRECT USE OF THE RAM.

Hydraulic products are only repaired by local service agents. We have service/repair agents in all parts of the UK. 

DO NOT RETURN RAM TO US.

Please telephone us on 01284 757500 to obtain the address and ‘phone number of your local

agent. If product is under guarantee please contact your dealer.

De-commissioning Hydraulic Pump/Ram

Should the ram become completely unserviceable draw off the oil into an approved container and dispose of the product and the oil

according to local regulations.

Declaration of Conformity 

We, the sole importer into the UK, declare that the product listed below is in

conformity with the following standards and directives.

SHORTY PUSH RAM

MODELS: RE97XS05,

RE97XS10, RE97XS20,

RE97XS30 

98/37/EC Machinery Directive

1st November 2004

Signed by Mark Sweetman

The construction file for this product is held by the Manufacturer

and may be inspected, by a national authority, upon request to

Jack Sealey Ltd.

For Jack Sealey Ltd.  

Sole importer into the UK of

Sealey Power Products.

Sole UK Distributor,

Sealey Group,

Bury St. Edmunds, Suffolk.

01284 757500

01284 703534

NOTE:

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required 

for any claim. 

INFORMATION: 

For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including

postcode.

RE97XS05, RE97XS10, RE97XS20, RE97XS30 - 1 - 091104

[email protected]

www.sealey.co.uk

e-mail

Web

p

p

WARNING! Ensure you have read and understood 

chapter 1 safety instructions. 

Note:  These instructions are intended to provide a guide to basic operation and are in no way intended to

replace the advice/instruction of a qualified specialist. 

Only fully trained persons should use this equipment.

4.1

Remove plug from ram connector (retain plug to reseal connector after use).

4.2

Connect to suitable hydraulic pump (see section 3).

4.3

Position ram as required and operate pump. 

IMPORTANT: Always store the ram with the piston fully retracted to help prevent corrosion. Rams with signs of 

rust on the main piston cannot be replaced under warranty.

PARTS FOR:    SHORTY PUSH RAM

Model:

RE97XS05, RE97XS10

RE97XS05, RE97XS10

RE97XS20, RE97XS30

RE97XS20, RE97XS30

3.

INTRODUCTION

Extremely short collapsed height makes these rams suitable for use where there is almost no clearance at the

lift point. Unique ram and cylinder bearings absorb eccentric load stresses in order to protect the cylinder

against abrasion, over-extension and jamming. Chromed rams with polyurethane seals and wipers provide

longer service life. Rams feature high flow quick connecting couplers with dust caps. Use in conjunction with

10T or 4T pump and hose (610/40, 610/42 or 604/40, 604/42

Reviews: