background image

5.3.10. 

W

hen you have finished the soap application, remove the bottle and flush clean water through the tube until it is cleaned thoroughly.

 note:

 Failure to clean properly will cause the injection system to become clogged and inoperable.

5.4. 

 

 

when washinG is CoMpleteD

5.4.1.   

Switch the power supply off by turning switch to ‘Off’ position (fiig.5).

5.4.2. 

  

turn off the water supply tap.

5.4.3. 

  

discharge residual pressure by pressing the trigger until no more water comes out of the nozzle.

 

‰

  

warninG!

 Failure to discharge pressure could result in personal injury.

5.4.4. 

  

disconnect the inlet and high pressure outlet hoses.

5.4.5.   

Wipe the machine clean and dry and store in a clean, safe, dry, childproof location.

 

note:

 a) 

Do not

 leave motor switched on for more than 15 minutes without operating trigger.

 

          b) if the water pressure drops (e.g. someone else using the same water supply), the washer will not operate correctly.  

 

 

              immediately switch the motor off and wait until the pressure is restored.

6. 

troubleshootinG

7.  MaintenanCe

 

‰

  

warninG!

 ensure the pressure washer is switched off and unplugged from the mains electrical power supply and turned off at the  

  mains water tap before performing any maintenance tasks. 

 

Check, clean or renew the inlet filter (which is fitted inside the inlet connector,) after every 50 hours of use.

 

Use only genuine Sealey spares for this machine. Failure to do so could result in personal injury and will invalidate the warranty.

7.1. 

  

nozzles

7.1.1. 

  

ensure that both nozzles are kept clean and free of debris.

7.1.2. 

  

the variable nozzle should be lubricated regularly. clogging of the nozzle causes the pump pressure to be too high and cleaning is  

 

immediately required. 

7.1.3.   

Separate the nozzle from the lance by unscrewing anti-clockwise (fig.4).

7.1.4. 

  

clear the nozzle of any debris.

7.1.5. 

  

flush the nozzle with water.

7.1.6. 

    reconnect the nozzle to the lance. ensure that the nozzle connection is tight.      

7.2. 

  

water Filter

7.2.1.   

The pressure washer is equipped with a water inlet filter to protect the pump.

7.2.2.   

To clean the conical filter, remove quick fit connection and the filter from the pump inlet.

7.2.3.   

Back flush the filter to clean.

7.2.4.   

Replace filter and quick connection immediately to prevent any ingress of foreign matter into the pump.

7.3. 

  

CoolinG sYsteM

7.3.1. 

  

the air vents, in and around the pressure washer, must be kept clean and free of any obstructions to ensure proper air cooling of the  

 

motor during operation.

 

‰

  

warninG!

 Prevent water from penetrating the vents of the pressure washer to minimise the risk of damage to the machine and to  

  reduce the risk of shock to the operator.

7.4. 

  

General

7.4.1. 

  

check unit, gun, nozzle, hose, connections and cables for damage. immediately replace or repair with genuine parts.

7.5. 

  

storaGe

7.5.1.   

Store in a location where the washer will not be subject to freezing conditions.

7.5.2. 

  

make sure that the pressure washer has been drained of water and remove the hoses.

P

W2200, PW2500 | Issue:4(L) 10/10/17

Original Language Version

© Jack sealey limited

sYmPtoms

reAson

remedY

motor will not start.

1. loose or disconnected plug.

2. Blown fuse.

1. reconnect plug.

2. see below

circuit breaker trips or fuse blown.

1. circuit overload.

2. extension cord too long or wire size too  

    small.

3. nozzle partially blocked, causing  

    excessive pressure.

1. check that the circuit is rated 13amps or  

    greater. disconnect all loads on the circuit.

2. use proper extension cord as  

    recommended in section 1.

3. clean nozzle as described in maintenance  

    section.

Water or oil leaking from bottom of pump.

1. A small amount of leakage is normal.

1. if excessive leaking occurs contact     

    authorised service agent.

trigger will not move.

1. Gun safety lock engaged.

1. release safety lock.

unit will not stop when trigger is released.

1. trigger system not operating properly.

1. contact authorised service agent.

motor running but pump not building. 

maximum pressure or has irregular pressure.

1. Water supply not turned on.

2. unit has been stored in freezing  

    temperatures.

3. Water inlet screen clogged.

4. Kink in supply hose.

5. nozzle worn out.

6. Air in pump.

7. Suction or discharge valves clogged or 

 

    worn out.

1. turn on water supply.

2. thaw out unit completely including hose,  

    gun and attachments.

3. clean screen as described in maintenance  

    section.

4. Straighten hose.

5. replace nozzle.

6. Let pressure washer run with gun open 

 

    and lance removed until a steady stream     

    of water is released.

7.Contact authorised service agent.