background image

                                                         WARNING! – Risk of Hand Arm Vibration Injury.

These tools may cause Hand Arm Vibration Syndrome if their use is not managed adequately.

These tools are to be operated in accordance with these instructions.

Model No:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SA12/S.V2  . . . . . . . . .SA2  . . . . . .SA21/S. . . . . SA67.V3

Measured vibration emission value (a):   . . . . . 13.25m/s²  . . . . . 5.67m/s²  . . . . .6.56m/s². . . . . 2.53m/s²

Uncertainty value (k):. . . . . . . . . . . . . . . . . . . . . . 1.09m/s²  . . . . . 0.64m/s²  . . . . .0.69m/s². . . . . 0.45m/s²  

Please note that the application of these tools to a sole specialist task may produce a different average vibration emission. We recommend that a

specific evaluation of the vibration emission is conducted prior to commencing with a specialist task.

A health and safety assessment by the user (or employer) will need to be carried out to determine the suitable duration of use for each tool. 

NB: 

Stated Vibration Emission values are type-test values and are intended to be typical. 

Whilst in use, the actual value will vary considerably from and depend on many factors.  

Such factors include; the operator, the task and the inserted tool or consumable. 

NB:

 ensure that the length of leader hoses is sufficient to allow unrestricted use, as this also helps to reduce vibration.

The state of maintenance of the tool itself is also an important factor, a poorly maintained tool will also increase the risk of Hand Arm Vibration 

Syndrome.

PREPARING FOR USE.

Air Supply.

WARNING! 

Ensure the air supply is clean and does not exceed 90psi while operating the tool.

Too high an air pressure and unclean air will shorten the product life due to excessive wear and may cause damage and/or personal injury.

Ensure that the tool air valve (or trigger) is in the “off” position before connecting to the air supply.

Monitor the compressor daily to ensure that moisture is not present in the compressed air. Water in the air line will damage the tool.

Line pressure should be increased to compensate for unusually long air hoses (over 8metres). 

The minimum hose diameter should be ¼” internal diameter. Fittings must have compatible inside dimensions.

Keep hoses away from heat, oil and sharp edges. Check hoses for wear and ensure that all connections are secure.

Couplings.

Vibration may cause failure if a quick change coupling is connected directly to the tool.

To overcome this, connect a leader hose to the tool (Sealey ref: AH2R or AH2R/38).

A quick change coupling may then be used to connect the leader hose to the air line recoil hose. 

CORRECT USE.

Vibration emission is closely linked to the operating pressure in the air supply. The user should ensure that the pressure is set in accordance with 

our recommendations to assure optimum efficiency and minimise vibration exposure.

•  Ensure that the tool is correctly aligned to the work. Misalignment increases the risk of vibration injury.

•  Ensure that consumables are selected, maintained and replaced in accordance with Sealey Instructions.

•  Sleeve fittings must be used where possible.

•  Always support the tool in a stand or on a balancer or a tension device where possible.

•  Ensure that the operator is sufficiently experienced in order to be able to handle and operate the tool correctly.

•  Ensure that the tool is held with a light but secure grip. Avoid excessive grip force as this will increase the risk of vibration injury.

Health surveillance.

We recommend a programme of health surveillance to detect early symptoms of vibration injury so that management procedures can be modified 

accordingly.

Personal protective equipment.

We are not aware of any personal protective equipment (PPE) that provides protection against vibration injury that may result from the uncon-

trolled use of this tool. We recommend a sufficient supply of clothing (including gloves) to enable the operator to remain warm and dry and main-

tain good blood circulation in fingers etc. Please note that the most effective protection is prevention, please refer to the Correct Use and 

Maintenance section in these instructions. Guidance relating to the management of hand arm vibration can be found on the HSC website www.

hse.gov.uk - Hand-Arm Vibration at Work.

Original Language Version

SA2004KIT  Issue:3(SP)-18/06/13

 © Jack Sealey Limited

Summary of Contents for Power Tools SA2004KIT

Page 1: ...thing and keep hands and body clear of working parts Keep children and unauthorised persons away from the work area Ensure that the workpiece is secure before operating the tool Never hold a workpiece by hand DO NOT operate tool when you are tired or under the influence of alcohol drugs or intoxicating medication WARNING Ensure correct air pressure is maintained and not exceeded Recommended pressu...

Page 2: ...m hose bore should be 1 4 and fittings must have the same inside dimensions 4 6 Keep hoses away from heat oil and sharp edges Check hoses for wear and make certain that all connections are secure 4 7 Couplings vibration may cause failure of a quick change coupling that is connected directly to the air tool To overcome this connect a leader hose Sealey model number AH2R to the tool A quick change c...

Page 3: ...change ratchet direction turn the switch on the tool head F Forward R Reverse 7 4 The flow of air torque may be regulated by turning the screw above the trigger fig 3 fig 4 One handed straight type die grinder with aluminium body and trigger with safety catch Chuck accepts grinding bits with Ø6mm shanks WARNING Ensure that you read understand and apply the safety instructions in Section 1 before u...

Page 4: ...um solvent oil or an equal mixture of SAE No 10 oil and paraffin Allow to dry before use 9 4 For a full service contact your local Sealey service agent 9 5 When not in use disconnect from air supply clean tool and store in a safe dry childproof location 9 6 Impact Wrench only Check and top up the gearbox oil by removing grub screw located on the right side above the grip NOTE It is our policy to c...

Page 5: ...ust have compatible inside dimensions Keep hoses away from heat oil and sharp edges Check hoses for wear and ensure that all connections are secure Couplings Vibration may cause failure if a quick change coupling is connected directly to the tool To overcome this connect a leader hose to the tool Sealey ref AH2R or AH2R 38 A quick change coupling may then be used to connect the leader hose to the ...

Reviews: