5.1.  Before first use.

5.1.1. Before using the truck for the first time purge any air from the  

 

hydraulic circuit by pumping the foot pedal 10 to 15 times  

 

whilst holding the release lever (fig.3A) in.

5.1.2. to test the truck, release the lever which will close the  

 

hydraulic valve. Pump the foot pedal (fig 1E) and raise the  

 

truck platform to its highest position and then pull the valve  

 

lever (fig 3.A) to lower the platform, (the platform may be slow  

 

to descend immediately from its highest point). If the platform  

 

fails to descend adjust the cable length to remove excess play  

 

in the release lever movement.

5.2.  using the truck

 

WarNiNG!

 Ensure you read, understand and follow the safety  

 

instructions. Ensure all Health and safety, local authority, and  

 

general workshop practice regulations and recommendations  

 

are strictly adhered to when lifting or moving heavy loads. the  

 

lifting or movement of heavy loads may be dangerous if not  

 

undertaken correctly.

5.2.1. Move the truck to the required loading area and raise the  

 

platform to loading height.

5.2.2. Lock the truck wheels individually with the wheel foot brakes.  

 

see fig.1.

5.2.3. Load the truck.

5.2.4. Lower the truck platform to the lowest position before   

 

unlocking the wheels. 

 

WarNiNG! 

Ensure the load will not foul on anything, and is  

 

clear of your hands and the handle when lowering (fig 4).

5.2.5. unlock the wheels and transport the load to the required  

 

destination.

5.2.6. to unload, lock the wheels and raise platform if required, then  

 

unload the truck.

 

Note:

 With or without a load, always transport the truck with  

 

platform in its lowest position.When not in use, store the truck  

 

with the platform in the lowest position.

5.  uSiNG thE truck

4.  aSSEmBly

4.1  A minimum of two people will be required to lift the truck out  

 

of its packaging. Alternatively, cut and fold down flat one end  

 

of the box and wheel the truck out. 

4.2 

fitting the handle.

 At the back of the truck there are two  

 

upstanding sockets to receive the bent loop handle (fig.1D).  

 

Partially unscrew the two locking bolts that pass into the  

 

sockets so that they no longer protrude into the sockets.  

 

Drop the ends of the bent chrome handle into the sockets  

 

and tighten the bolts until the handle is held firmly. 

 

Model HPt400H has a different handle fixing arrangement.  

 

the ends of the chrome handle have flanges which sit down  

 

onto flat platforms at either side of the truck. see fig.6X. the  

 

handle is retained by two large socket cap bolts inserted from  

 

underneath. You will require a 10mm Allen Key to tighten the  

 

bolts. Place a split washer followed by a plain washer over  

 

each bolt before inserting and tightening.

4.3 

fitting the foot pedal.

 slide the end of the foot pedal into  

 

the socket situated centrally between the two handle uprights.  

 

(see fig.1E). on some models the footpedal retaining bolt (see  

fig.1f) screws directly into the material of the foot pedal stem.  

 

In this case place a split washer over the bolt followed by a  

 

plain washer, before inserting the bolt. on other models the  

 

bolt passes directly through the stem and the socket and is  

 

retained with a plain washer followed by a split washer  

 

followed by a nut. Ensure the fixing arrangement is tight  

 

enough to hold the pedal firmly in place (do not over tighten).

4.4 

connecting the control cable

. remove the cable guide  

 

bush (fig.2B) from the free end of the cable and feed the end  

 

of the cable and cable sheath through the cable guide tubes  

 

welded to the handle and the underside of the frame. see  

 

fig.1G and fig.2A. the exact position and number of the  

 

guides may vary from model to model. once the cable has  

 

been fed through the guides slide the bush back over the  

 

cable and onto the sheath. feed the cable through the hole  

 

in the bush retaining bracket and then through the hole in the  

 

clamping bolt on the actuating lever (fig.2c). now screw the  

 

guide bush into the bracket with a 12mm spanner (see  

 

fig.2b). Pull the end of the cable to so that there is no play in  

 

the movement of the lever mounted on the handle. Hold the  

 

clamping bolt (fig.2c) steady with a 12mm ring spanner and  

 

tighten the nut on the other side of the lever with a 13mm  

 

ring spanner.  

fig.1

fig.2

fig.3