background image

INSTRUCTIONS FOR:

PILLAR DRILLS WITH

DIGITAL VARIABLE SPEED

MODEL NO:

PDME160B & PDME200F

1. SAFETY INSTRUCTIONS

PDME160B-PDME200F - 1 - 151204

1.1

ELECTRICAL SAFETY

WARNING!

It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and 

any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of 

appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also 

recommend that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are 

plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual 

Current Device by contacting your Sealey dealer. 

You must

also read and understand the following instructions concerning electrical safety.

1.1.1 The 

Electricity at Work Act 1989 

requires all portable electrical appliances, if used on business premises, to be tested by a qualified 

electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2 The 

Health & Safety at Work Act 1974 

makes owners of electrical appliances responsible for the safe condition of those appliances 

and the safety of the appliance operators. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3 Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1 and 1.1.2 

and use a Portable Appliance Tester.

1.1.4 Ensure that cables are always protected against short circuit and overload.

1.1.5 Regularly inspect power supply cables and plugs for wear or damage and check all

connections to ensure that none is loose.

1.1.6

Important:

Ensure that the voltage marked on the appliance matches the power supply 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7

DO NOT

pull or carry the appliance by the power cable.

1.1.8

DO NOT 

pull the plug from the socket by the cable.

1.1.9

DO NOT

use worn or damaged cables, plugs or connectors. Immediately have any faulty 

item repaired or replaced by a qualified electrician. When an ASTA/BS approved UK 

3 pin plug is damaged, cut the cable just above the plug and 

dispose of the plug safely. 

Fit a new plug according to the following instructions (UK only).

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

b) Connect the BROWN live wire to the live terminal ‘L’.

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer 

insulation extends beyond the cable restraint and that the restraint is tight.

Double insulated products, which are always marked with this symbol      , are fitted with live (brown) and neutral (blue) wires only. 

To rewire, connect the wires as indicated above - 

DO NOT

connect either wire to the earth terminal.

1.1.10 Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure 

that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket 

with your electrician.

1.1.11 If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance 

plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the 

capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use 

of 2.5mm² section cable. If extension reel is to be used outdoors, ensure it is marked for outdoor use.

1.2

GENERAL SAFETY

p

WARNING! Disconnect drill from mains power before changing accessories, servicing or performing any maintenance.

3

Maintain the drill in good condition (use an authorised service agent).

p

WARNING! Keep all guards and holding screws in place, tight and in good working order. Check regularly for damaged parts. A

guard or any other part that is damaged must be repaired or replaced, before the tool is used, to ensure that it will operate 

properly and perform its intended function. The safety guard is a mandatory fitting where drill is used in premises covered by 

the Health & Safety at Work Act.

3

Check alignment of moving parts and check for possible broken parts. 

3

Replace or repair damaged parts. 

Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

3

Ensure the set screws of the head frame are screwed tight before using the drill.

3

Secure the drill to the bench/floor to avoid it tipping, sliding or walking. 

3

Drill is designed for use with drill bits only. 

3

Ensure the chuck is securely fastened to the spindle.

3

Remove adjusting keys, chuck key and wrenches from the machine and working area before switching on.

3

Use clamps or a vice (not included, but available from your Sealey dealer) to secure the workpiece. 

DO NOT

attempt to hold the 

workpiece by hand. 

3

Refer to speed chart for recommended drilling speeds.

p

WARNING! Always wear approved eye or face protection when operating this drill. Use a face or dust mask if dust is generated. 

p

WARNING! DO NOT wear gloves when drilling.

3

Others in the workplace should keep a safe distance from the drill, especially when it is in operation. 

3

Keep the work area as childproof as possible by using padlocks and master switches.

3

Keep drill bits clean and sharp for best and safest performance. Follow the instructions for lubrication and changing accessories.

FUSE RATING 13 AMP

Blue

Neutral 

Wire

Yellow & Green 

Earth Wire 

Cable 

Restraint

Brown

Live 

Wire

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and

properly maintained, give you years of trouble free performance.

IMPORTANT

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND

CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO

MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.

Summary of Contents for PDME160B

Page 1: ...wire to the earth terminal 1 1 10 Products which require more than 13 amps are supplied without a plug In this case you must contact a qualified electrician to ensure that a suitably rated supply is available We recommend that you discuss the installation of an industrial round pin plug and socket with your electrician 1 1 11 If an extension reel is used it should be fully unwound before connectio...

Page 2: ...d RPM is displayed on the front digital LCD panel Meets CE Machinery Directive 98 37 EC Low Voltage Safety Directive 79 23 EEC and EMC Directive 89 336 EEC Safety devices fitted include a no volt release switch allowing insurance company approval for use in educational establishments Supplied with chuck guard Model PDME160B Chuck size 16mm Spindle Nose Taper MT2 Swing 430mm Chuck to Upright Face 1...

Page 3: ...fig 1 fig 5 fig 2 fig 3 fig 4 PDME160B PDME200F 1 151204 ...

Page 4: ...the drilling speed while the drill is not running or when it is slowing down 4 3 2 Choose the speed for drilling operation carefully before you begin to drill the workpiece see drill speed chart Section 5 4 3 3 To reset the digital display during operation press the reset button located below the LCD panel fig 7 5 4 4 POSITIONING THE WORKPIECE 4 4 1 To prevent table damage rest the workpiece on a ...

Page 5: ...ten the rack 7 TROUBLESHOOTING 6 1 Clean the tool after each use A coat of automobile type wax applied to the table and column will help to keep the surfaces clean 6 2 Blow out any dust that may have accumulated in the motor 6 3 Periodically lubricate the table elevation rack gear worm mechanism and the spindle sleeve exterior 6 MAINTENANCE 5 DRILL SPEEDS PDME160B PDME200F 1 151204 Declaration of ...

Reviews: