5.2.    

Emptying dust tank

(fig.4)

5.2.1.   

Turn off cleaner and disconnect from power supply. (fig.4.2) (fig.4.3)

5.2.2.   

Release side clips (fig.4.4) and lift off top assembly and filter 

 

assembly. (fig.4.5) (fig.4.6)

5.2.3. 

  

Carefully empty contents of cleaner body into suitable receptacle. (fig.4.7)

5.2.4.   

Separate filter assembly and clean off (brush gently or shake) into 

 

suitable receptacle. (fig.4.8)

5.2.5. 

  

Reassemble filter and replace into cleaner body. (fig.4.9) (fig.3.6) 

5.3.    

Wet vacumming. (fig.5)

5.3.1.   

Ensure machine is disconnected from power supply.

5.3.2.  `  Remove HEPA filter from filter arrangement. 

5.3.3.   

Check that filter components are assembled correctly. (fig.5.1)

5.3.4.   

Install filter assembly into cleaner body. (fig.5.2) 

5.3.5.   

Install top assembly and lock in place. (fig.5.3)

5.3.6. 

  

Connect to power supply and power on. (fig.5.4) (fig.5.5)

5.3.7.   

When maximum capacity is reached the machine will stop running. (fig.5.6)

5.3.8. 

  

Turn off the power and disconnect from the power supply. (fig.5.7) (fig.5.8)

5.3.9.   

Unscrew drain cover and carefully empty contents of cleaner body int

 

suitable receptacle. (fig.5.9)

Original Language Version

© Jack Sealey Limited

fig.4

P

C300BL   Issue 2 (2,3)  7/3/19

Summary of Contents for PC300BL

Page 1: ...e earth terminal E B Connect the BROWN live wire to the live terminal L C Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 2 GENERAL SAFETY 9 9 Disconnect the cleaner from the power supply before servicing changing a...

Page 2: ... release clasps and blower Supplied with a 4 5m cable and approved plug hose assembly metal telescopic tube wet and dry floor nozzle crevice tool and multi brush 3 SPECIFICATION Model No PC300BL Motor 230V 1200W Max Vacuum Pressure 180mbar Air Flow 158m3 h Container 30ltr Weight 11kg Vac Accessories Ø35mm Filter Dry PC300BLPF Filter Wet PC300BLFF10 Pack of 10 4 ASSEMBLY 4 1 Carton content fig 1 4 ...

Page 3: ...red extension tubes and nozzle and connect onto the hose fig 2 12 fig 2 13 5 OPERATION WARNING Ensure you read understand and apply Section 1 Safety Instructions Reminder DO NOT vacuum hazardous substances Use of an incorrect cartridge filter will invalidate your warranty 5 1 Dry Vacuuming fig 3 5 1 1 Ensure the machine is unplugged from the power supply fig 3 1 5 1 2 Loosen clips fig 3 2 and remo...

Page 4: ...3 1 Ensure machine is disconnected from power supply 5 3 2 Remove HEPA filter from filter arrangement 5 3 3 Check that filter components are assembled correctly fig 5 1 5 3 4 Install filter assembly into cleaner body fig 5 2 5 3 5 Install top assembly and lock in place fig 5 3 5 3 6 Connect to power supply and power on fig 5 4 fig 5 5 5 3 7 When maximum capacity is reached the machine will stop ru...

Page 5: ...cuum followed by Auxiliary power 5 5 7 The vacuum will switch off when power is not being drawn through by the auxiliary device within approximately 10 seconds 6 MAINTENANCE 6 5 1 Ensure the machine is unplugged from the power supply 6 5 2 Disconnect the hose from the container 6 5 3 Undo the clasps and remove motor head from the container 6 5 4 Clear out any dirt or debris from the container and ...

Page 6: ...orted taken to a recycling centre and disposed of in a manner which is compatible with the environment When the product becomes completely unserviceable and requires disposal drain any fluids if applicable into approved containers and dispose of the product and fluids according to local regulations Note It is our policy to continually improve products and as such we reserve the right to alter data...

Reviews: