13.6.

 

Maintenance of the equipment.

 The equipment should be routinely maintained according to these instructions. All access and service  

 

covers should be closed and properly fastened when the welding equipment is in operation. The welding equipment should not be  

 

 

modified in any way except for those changes and adjustments covered in these instructions. In particular, the spark gaps of any arc    

 

striking and stabilising devices should be adjusted and maintained according to the instructions.

13.7.

 

Cables.

 The welding/cutting cables should be kept as short as possible and should be positioned close together, running at or close 

 

to the floor level.

13.8.

 

Equipotential bonding.

 Bonding of all metallic components in the welding/cutting installation and adjacent to it should be considered.   

 

However, metallic components bonded to the workpiece will increase the risk that the operator could receive a shock by touching these  

 

metallic components and the electrode at the same time. The operator should be insulated from all such bonded metallic components. 

13.9.

 

Earthing of the workpiece.

 Where the workpiece is not bonded to earth for electrical safety, nor connected to earth because of its size  

 

and position, e.g. ship’s hull or building steelwork, a connection bonding the workpiece to earth may reduce emissions in some, but not  

 

all instances. Care should be taken to prevent the earthing of the workpiece increasing the risk of injury to others or damage to other    

 

electrical equipment. Where necessary, the connection of the workpiece to earth should be made by a direct connection to the  

 

 

workpiece, but in some countries where direct connection is not permitted, the bonding should be achieved by a suitable capacitance,   

 

selected according to national regulations.

13.10.

selective screening and shielding of other cables and equipment in the surrounding area may alleviate problems of interference.  

 

 

screening of the entire welding/cutting installation may be considered for special applications. 

Original Language Version

NOTE:

 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION:

 For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group, 

Kempson Way, suffolk Business Park

Bury st. edmunds, suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

MW131, MW151,  MW151PlUs     Issue No.1    24/10/11

Summary of Contents for MW131

Page 1: ...MW131 MW151 MW151PLUS Models INSTRUCTIONS FOR INVERTERS MW131 MW151 MW151PLUS Issue No 1 24 10 11 ...

Page 2: ... beyond the cable restraint and that the restraint is tight Double insulated products which are always marked with this symbol are fitted with live brown and neutral blue wires only To rewire connect the wires as indicated above DO NOT connect either wire to the earth terminal 1 1 10 Products which require more than 13 amps are supplied without a plug In this case you must contact a qualified elec...

Page 3: ...at selected by the user It modulates the commands of the IGBT drivers which control regulation The control board also determines the dynamic response of the current transient during the phases of electrode fusion instant short circuit and is responsible for the safety system 2 description 3 specification 3 1 SPECIFICATION Model No MW131 MW151 MW151PLUS Peak Power 130A 150A 150A Output 10 130A 10 1...

Page 4: ...o the back of the arm with the bare wire under the plate Tighten the clamp screw 5 1 3 Slide the black rubber sleeve back over the clamp arm 5 2 Electrode Holder See fig 4 B 5 2 1 Undo the handle retaining screw Pull the handle from the head and thread the free end of the cable through it as shown Remove the pre cut section of insulation from the cable end 5 2 2 Loosen the clamp screw on the handl...

Page 5: ...elding mask in front of your face before striking the arc 9 1 ARC WELDING 9 1 1 Strike the electrode tip on the workpiece as if you were striking a match WARNING DO NOT hit the electrode on the workpiece as this may damage the electrode 9 1 2 As soon as the arc is struck maintain a distance from the workpiece equal to the diameter of the electrode Keep this distance as constant as possible for the...

Page 6: ...or may not be earthed for safety reasons Changing the earthing arrangements should only be authorised by a person who is competent to assess whether the changes will increase the risk of injury e g by allowing parallel welding cutting circuit return paths which may damage the earth circuits of other equipment Further guidance is given in IEC 974 13 Arc Welding Equipment Installation and Use 13 4 A...

Page 7: ...ection bonding the workpiece to earth may reduce emissions in some but not all instances Care should be taken to prevent the earthing of the workpiece increasing the risk of injury to others or damage to other electrical equipment Where necessary the connection of the workpiece to earth should be made by a direct connection to the workpiece but in some countries where direct connection is not perm...

Reviews: