DIODE AND CONTINUITY

 

Range 

Description 

  Remark

 

  

The display shows the approx. forward  Open Circuit Voltage

 

 

voltage drop of the diode.             

about 2.5V

 

 

   Max. 

Test 

Current:

 

 

   1mA

 

 

The built in buzzer will sound if the

 

 

resistance is less than about 30Ω.

 

 

The buzzer may not sound if the 

Open Circuit Voltage

 

 

resistance is between 30Ω and 100Ω.  about 2.5V

 

 

The buzzer will not sound if the 

 

 

resistance is more than 100Ω.

 

Overload Protection: 

250V DC/AC rms

Original Language Version

 MM18  Issue No:2(I)-09/09/14

Summary of Contents for MM18

Page 1: ...round yourself whilst using the meter When a probe is connected to a dangerous live potential it must be noted that this potential can occur at the other probe NOTE CAT II measurement category is for measurements performed on circuits directly connected to low voltage installations Examples are measurements on household appliances portable tools and similar equipment DO NOT use the meter for measu...

Page 2: ...ity 75 Storage Temperature 10 C to 50 C Relative Humidity 85 1 Display 3 digit LCD with a max reading of 1999 2 Function Used to select desired function 3 Range Switch Used to select desired range 4 Test Probes DC VOLTAGE Range Resolution Accuracy 2V 0 001V 20V 0 01V 200V 0 1V 1 0 5 digits 250V 1V Input Impedance 1MΩ Max Allowable Input Voltage 250V dc AC VOLTAGE Range Resolution Accuracy 200V 0 1...

Page 3: ...about 2 5V Max Test Current 1mA The built in buzzer will sound if the resistance is less than about 30Ω The buzzer may not sound if the Open Circuit Voltage resistance is between 30Ω and 100Ω about 2 5V The buzzer will not sound if the resistance is more than 100Ω Overload Protection 250V DC AC rms Original Language Version MM18 Issue No 2 I 09 09 14 ...

Page 4: ... a few seconds to stabilise a reading This is normal for high resistance measurements 2 When the test leads are in open circuit state 1 will be dsplayed as an overrange indication 3 Before measurement disconnect all power to the circuit to be tested and discharge all capacitors thoroughly 4 5 DIODE TEST 4 5 1 Set the function to the position 4 5 2 Set the range switch to the position 4 5 3 Connect...

Page 5: ... end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information Battery Removal WARNING To avoid electric shock disconnect the test leads from any source of voltage before removing the battery...