background image

  1.  SAFETY INSTRUCTIONS

1.1. 

ELECTRICAL SAFETY 

  

WARNING! Electrical installation of the light must only be carried out by a qualified electrician. Make sure that power 

 

supply cable is correctly connected to earth. It is the user’s responsibility to read, understand and comply with the following: 

 

You must check all electrical equipment and appliances before use, to ensure that they are safe. You must inspect power supply  

 

 

leads, plugs and all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the 

 

installation of appropriate safety devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution  

 

board. We also recommend that an RCD (Residual Current Device) is used with all electrical products. It is particularly important to    

 

use an RCD together with portable products that are plugged into an electrical supply not protected by an RCCB. If in doubt consult a  

 

qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer. 

You must

 also read and understand  

 

the following instructions concerning electrical safety.

1.1.1  The 

Electricity At Work Act 1989

 requires all portable electrical appliances, if used on business premises, to be tested by a qualified  

 

electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2  The 

Health & Safety at Work Act 1974

 makes owners of electrical appliances responsible for the safe condition of the appliance 

 

and the safety of the appliance operator. 

If in any doubt about electrical safety, 

 

contact a qualified electrician. 

1.1.3  Ensure the insulation on all cables and the product itself is safe before connecting to  

 

the power supply. See 1.1.1 & 1.1.2 above and use a Portable Appliance Tester (PAT).

1.1.4  Ensure that cables are always protected against short circuit and overload.

1.1.5  Regularly inspect power supply, leads, plugs and all electrical connections for wear 

 

and damage, and power connections to ensure that none is loose. 

1.1.6 

Important: 

Ensure the voltage marked on the product is the same as the electrical  

 

power supply to be used.

1.1.7 

DO NOT

 pull or carry the appliance by the power supply or output cables. 

1.1.8 

DO NOT

 pull power plug from socket by the power cable.

1.1.9 

DO NOT

 use this product with an extension cable

.

1.1.10 

DO NOT

 use worn or damage leads, plugs or connections. Immediately replace or have  

 

repaired by a qualified electrician. 

1.1.11 

Supply: 230Vac 1ph protected by a 16 amp delayed fuse or equivalent breaker, or

 

           110Vac 1ph protected by a 25 amp delayed fuse or equivalent breaker.

1.1.12  Fit a plug according to the following instructions (see diagram at right - 110V plug    

 

shown). 

 

Ensure the unit is correctly earthed via a three-pin 110V 25A or 230V 32A plug  

 

(not supplied) to suit supply (see 1.1.11). 

 

a)  Connect the grEEn/YElloW earth wire to the earth terminal       .

 

b)  Connect the broWn live wire to the live terminal ‘l’.

 

c)  Connect the bluE neutral wire to the neutral terminal, unmarked.

 

d)  After wiring, check that there are no bare wires, that all wires have been 

 

   correctly connected, that the cable outer insulation extends past the cable  

 

    restraint and that the restraint is tight.

 

  

WArnIng! 

Reminder, the electrical installation of the light must only be carried out by a qualified electrician. Make sure that power    

 

supply cable is correctly earthed.

  

WArnIng! 

Be very cautious if using a generator to power the light. The generator must be self-regulating and stable with regard to    

 

voltage, wave form and frequency. The output must be greater than the power consumption of the light. If any of these requirements   

 

is not met the electronics within the light may be affected.

note:  The use of an unregulated generator may be dangerous and will invalidate the warranty on the light.

1.2 

GENERAL SAFETY

  

Keep the light, cables, holder and clamps in good working order and condition and take immediate action to repair or replace 

 

damaged parts

.

  

Use recommended parts and accessories only. 

Unapproved parts may be dangerous and will invalidate the warranty.

 

  

Only use the electrode holder provided with the system and ensure any replacement is of the same type.

 

WARNING! Disconnect light from mains power before changing tubes or performing any maintenance.

 

Replace or repair damaged parts. 

Use genuine Sealey parts only. Unauthorised parts may be dangerous and will invalidate the 

 

warranty.

 

Maintain the light in good condition.

 

DO NOT

 use the light if damaged.

 

DO NOT

 use light close to paint fumes, solvents or other flammable liquids or flammable waste, such as wipes or cleaning rags. 

 

DO NOT

 fit a fluorescent tube other than the recommended replacement. (SEALEY PART NO. 

ML36110F.FB

 

When not in use switch off the light and remove plug from power supply. 

 

DO NOT allow children to use the light.

 

When not in use store the light in a safe, dry, childproof location. 

INSTRUCTIONS FOR:

FLUORESCENT FLOOR LIGhT

MODEL NO:

 

ML36110F

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and 

properly maintained, give you years of trouble free performance.

IMPorTAnT

PLEASE READ ThESE INSTRUCTIONS CAREFULLY. NOTE ThE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND 

CAUTIONS. USE ThIS PRODUCT CORRECTLY, AND WITh CARE FOR ThE PURPOSE FOR WhICh IT IS INTENDED. FAILURE TO DO SO 

MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE ThE WARRANTY.

Original Language Version

ML36110F    Issue: 2 - 23/07/10

Reviews: