background image

4.  mAiNtENANCE

  

WArNiNg!

 Be sure to disconnect the lamp from the mains power supply before carrying out any maintenance.

4.1 

Keep the lamp clean.

4.2 

check cable for any signs of wear. If the plug and/or cable are worn/broken, remove the lamp from service immediately and have it    

 

repaired by a qualified electrician. 

4.3 

to change the fluorescent tube, unscrew the four cover retaining screws on the rear of the lamp casing. 

4.4 

remove the retaining band from the top of the tube.

4.5 

Holding the tube near the bottom, gently lever from side to side whilst applying an upward force.

4.6 

Insert a new tube using a lint-free cloth to handle the new tube. ensure that the tube is seated correctly.

4.7 

refit the retaining band.

4.8 

screw the cover back into place. 

5.  spArE pArts

fluorescent tube:   Ml33B         sPAre tuBe for Ml33 11WAtt

retaining Band

retaining clip

Parts Issue: 

1

Issue date: 

07072004

3.  opErAtioN

3.1 

Plug the lamp into the mains supply and switch on. 

3.2 

When finished, turn off the lamp using the mains supply switch. 

NOTE:

 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

importANt: 

no liability is accepted for incorrect use of this product. 

WArrANtY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

iNformAtioN:

 for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

sole Uk distributor, sealey group, 

Kempson Way, suffolk Business Park

Bury st. edmunds, suffolk,

IP32 7Ar

www.sealey.co.uk

Web

email

Original Language Version

Ml33    Issue: 2 - 12/01/10

Reviews: