background image

The heater may also be used as a cool air fan, as follows:

5.1.

  Remove the gas supply hose and plug the heater into the mains electrical power supply.

5.2.

  Switch on the fan. The unit will now blow out cool air only.

   5.  COOL AIR FAN

   6.   MAINTENANCE

   8.   DECLARATION OF CONFORMITY

 

WARNING! 

Before commencing service or maintenance disconnect the unit from the electrical power and the gas supply. Use authorised parts 

only.  

   

Unauthorised parts may be dangerous and will invalidate the warranty. 

6.1.

 

Check the gas supply hose condition and change if necessary.

6.2.

 

Check the starting electrode gap (fig. 8).

6.3

Check the ignition unit, safety thermostat, and thermocouple condition 

 

and ensure that they are clean.

 

Caution:

 Wear safety goggles to perform this operation.

6.4.

 

Clean inside the heater unit and the fan blade with compressed air. 

fig. 8

5mm

  7.  TROUBLESHOOTING

 

Declaration of Conformity 

We, the sole importer into the UK, declare that the products listed here are in conformity with the following standards and directives.

For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.

21st January 2008

Propane Heaters

LP35, LP70, LP80, LP100, LP125, LP200 & LP300

2006/95/EC Low Voltage Directive 

2004/108/EC EMC Directive 

93/68/EEC CE Marking Directive

Gas Appliances (Safety) Regulations 1992

2006/42/EC Machinery Directive

LP35.V5, LP70, LP80.V4, LP100.V2, LP145.V2, LP200.V3 & LP300.V4 - 2 - 210108

NOTE:

 

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

no liability is accepted for incorrect use of this equipment.

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: 

For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

Signed by Mark Sweetman

The construction files for these products are held by the Manufacturer and may be inspected, by a 

national authority, upon request to Jack Sealey Ltd.

01284 757500

01284 703534

[email protected]

Sole UK Distributor

Sealey Group,

Bury St. Edmunds, Suffolk.

www.sealey.co.uk

Web

email

PROBLEM

POSSIBLE CAUSE

SOLUTION

The fan motor does not work

1. There is no electrical supply. 

2. The motor has locked.

1. Check mains power supply, wire, plug, fuse.

2. Unlock the motor with appropriate tool.

The ignitor does not spark

1. Electrode has the wrong gap. 

2. Faulty connection.  

1. Check and reset the electrode to the correct position (fig. 7).

2. Check and connect correctly the ignitor and the electrode.

no gas flow to the burner

1. The cylinder gas tap is closed.  

2. The cylinder is empty.  

3. Gas leaks from the supply.

1. open the gas tap.

2. Replace the cylinder.

3. Remove and clean the nozzle, check for leaks by using a  

  foamy soap only 

DO NOT USE FLAME to find leak.

The burner starts, but it stops as 

the gas valve is released.

1. The thermocouple is not warm enough.  

2. The safety override has activated 

  because the fan does not work.

1. Repeat the starting operation keeping the button pushed for        

  a longer time

2. See above “Motor does not work”

   

 

The heater stops during operation 1. Excessive gas supply. 

2. Insufficient air flow.  

3. Insufficient  gas due to ice formation 

  on the cylinder.

1. Check the pressure reducer, and replace if necessary.

2. Check that the motor is working correctly.

3. Check and if necessary use a larger gas cylinder or multiple  

  cylinders connected parallel.